• 제목/요약/키워드: 시설재설계

Search Result 221, Processing Time 0.023 seconds

A Numerical Study on Safety Evaluation of Prefabricated Sewage-Pipe Plastic Foundation Based on Pipe Diameters and Buried Soil Depths (하수관거 직경과 심도를 고려한 하수관거 플라스틱 받침기초의 안전성 평가를 위한 해석연구)

  • Park, Rae-Jin;Park, Jong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4322-4327
    • /
    • 2015
  • Improper backfill materials and compaction controls under pipelines have become one of the major causes of failure in many sewage pipeline systems. A study on backfill materials and compaction controls has been considered for a long time. However, structural supporters under the pipe were recently concerned because of pipeline repair and maintenance. This paper presents a prefabricated plastic foundation for supporting a sewage pipe system and increasing the performance function of the pipes. Several analytical models for the plastic foundations were investigated using finite-element program, ABAQUS, for checking safety. Comparing with the results of analyses, some of economic design sections based on the sizes of pipe diameters, 600mm, 700 and 600mm, were evaluated. These results could be applied to a pipeline system with a prefabricated plastic foundation with respect to pipe diameters and buried depths.

Impact Resistance Characteristics of Cementitious Composites Subjected to High-velocity Projectiles with Reinforcement Types (고속 발사체와 충돌한 시멘트복합체의 보강재 종류에 따른 내충격 특성 연구)

  • Seok, Won-Kyun;Kim, Young-Sun;Lee, Yae-Chan;Nam, Jeong-Soo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.261-272
    • /
    • 2023
  • This research concentrates on the potential explosion hazards that could arise from unforeseen accidents in the rapidly proliferating hydrogen refueling stations and Energy Storage System(ESS) facilities. It underscores the pivotal role of structural protection technology in alleviating such risks. The research contributes primary data for the formulation of structure protection design by assessing the impact resistance across various reinforcement techniques used in cement composites. The experimental results elucidate that reinforced concrete, serving as the quintessential structural material, exhibits a 20% advancement in impact resistance in comparison to its non-reinforced counterpart. In situations typified by rapid loads, such as those seen with high-velocity impacts, the reinforcement of the matrix with fibers is demonstrably more beneficial than local reinforcement. These insights accentuate the importance of judiciously choosing the reinforcement method to augment impact resistance in structural design.

Analysis of Performance Tests and Friction Characteristics of a Friction Type Isolator Considering Train Load Conditions (열차 하중조건을 고려한 마찰형 방진장치 성능시험 및 마찰특성 분석)

  • Koh, Yong-Sung;Lee, Chan-Young;Ji, Yong-Soo;Kim, Jae-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.694-702
    • /
    • 2017
  • In the case of an elevated railway station, structure borne noise and vibration due to structural limitations allow the load and vibration from railway vehicles to be directly transmitted to the station structure, resulting in an increase in the number of civil complaints from customers and staff of the station. The floating slab track system, which is well known as one of the solutions for reducing the noise and vibration from elevated railway stations, usually contains rubber mounts or rubber pads under the railway slab which act as a damper. These types of device have the disadvantage that is difficult to predetermine the exact stiffness and damping ratio under the nonlinear loads resulting from train services. In this study, an isolator with a friction type of wedge is introduced, which can be applied to floating slab track systems and to be designed with precisely the required stiffness. Furthermore, a comparative analysis of the stiffness between the designed and experimental values is carried out, while the damping ratio, which is closely related to the friction wedge blocks, is deduced according to the train load condition. The performance tests of the isolator were conducted in accordance with the DIN 45673-7 standard which includes both static and dynamic load tests. The load conditions for the performance tests are designed to conform to the DIN standard related to the weight of the train and rail track, in order to perform vertical and horizontal load tests, so as to ensure the secure structural safety of the railway. Also, by checking the change aspect of the friction coefficients of the friction elements according to the loading rate, the vibration reduction performance of the friction type isolator with variable loading rate conditions is examined.

A Study of Prestressed Concrete Pile Stiffness for Structural Analysis of Condominium Remodeling with Vertical Story Extension (수직증축형 공동주택 리모델링 구조해석을 위한 PC말뚝 강성에 관한 연구)

  • Choi, Changho;Lee, Hyunjee;Choi, Kisun;You, Youngchan;Kim, Jinyoung
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.81-92
    • /
    • 2017
  • According to the revision of the Housing Act in 2013, it has been possible to carry out an apartment remodeling project involving two to three floor vertical extension. The remodeling project with vertical extension requires foundation reinforcement because structural safety due to additional load and enhanced seismic criteria must be met. In this case, structural analysis is performed to analyze the load distributed to existing PC pile and reinforced additional pile. The vertical stiffness ($K_v$) of the pile is required for structural analysis, but the research on the 20~30 year old PC pile stiffness is very limited. In this paper, the stiffness of the PC pile in accordance with the change of diameter and length was analyzed by examining the results of 38 field pile load tests performed during the construction of the apartments in the 1990's. As a result of the analysis, the pile stiffness decreases with the increase of the length-diameter ratio (L/D). In addition, the results of on-site pile load test are compared with the coefficient 'a' for estimating pile stiffness proposed in Korea Highway Bridge Design Standard (2008) and the Pile Foundation Design Guideline of Korea Railroad Corporation (2012). It shows that 'a' obtained through the estimation of the literature is very similar to the field test results in the range of 10

A Design Aspects of Historic Parks Preserving Buried Cultural Heritages - In the Case of Neunggok Prehistoric Remains Park, Ansan Singil Historic Park, Yongjuk Historic Park - (매장문화재 보존형 역사공원의 설계 양상 - 능곡선사유적공원, 안산신길역사공원, 용죽역사공원을 대상으로 -)

  • Kim, Ki-Uk;So, Hyun-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.12-22
    • /
    • 2019
  • This study derived the design aspects by carrying out the case study of Neunggok prehistoric remains park, Ansansingil historic park and Yongjuk historic park to which are taken measures to preserve undesignated cultural heritages after studying the related laws & regulations and the systems as the design conditions of historic park preserving buried cultural heritages. The results of the study are as follows. First, according to the laws & regulations related to the historical parks, the historic sites should be preserved and utilized at the same time and can have history-related facility spaces, squares, rest spaces, exercise spaces, education & culture space, and convenience spaces. Second, by the space organization and the circulation system emphasizing only the preservation of buried cultural heritages, the feature-preservation space and the functional space are separated and due to not accepting the usage behavior considering peripheral land use, the effectiveness of the historical park was low. Third, the passive feature-preservation methods such as the preservation of the exposed site in architectural methods, the reproduction of the dugout hut, and the planting Royal azaleas or displaying stone after covering up the location of the pit dwellings with soil and the usage mainly for viewing have weakened the identity of the historical park. Fourth, the fence preventing users' access interferes experiencing the features, and the vertical structure protecting the upper part of the exposed features has overwhelmed the landscape of the historical parks. Fifth, it was difficult to figure out the feature space only by the texts mainly on terminologies and the excavation photographs presented on the information signs which introduce the buried cultural heritages.

개발사업으로 인한 토양손실량 예측 및 침사지 설계

  • 우효섭;김창완
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1998.02d
    • /
    • pp.1101-1179
    • /
    • 1998
  • 최근에 내무부에서는 개발사업으로 인한 토사유출 피해 중 인명과 재산 피해와 같은 재해 성격을 가진 대규모 토사유출을 사전에 미리 저감시킬 목적으로 재해영향평가제를 도입하여 추진하고 있다. 이에 따라 건설 엔지니어링 업계에서는 대규모 개발 사업으로 인한 가속화된 토양손실량 예측과 침사지 설계에 많은 관심이 쏟아지고 있으나 이 분야의 기술축적과 자료부족으로 과업수행에 어려움을 겪고 있다. 본 강좌에서는 이러한 엔지니어링 업계의 기술적인 어려움을 다소 나마 해소할수 있도록 개발사업으로 인한 가속화된 토양손실량 예측방법과 침사지 설계 기준에 대해 외국의 자료를 바탕으로 그 동안 국내에서 수행한 각종 재해영향평가 자료를 검토하여 제시한다. 먼저, 재해영향평가제의 취지, 토사유출과 재해, 토사유출 재해 저감대책 등에 대해 간략히 설명한다. 다음, 침식량 예측 방법으로 미국의 범용토양 손실공식(USEL) 방법의 적용 절차에 대해 구체적으로 소개한다. 침사지 설계 편에서는 침사지 설계 개념과 구체적인 설계 절차를 제시하고 참사지 규모의 결정방법을 소개한다. 본 강좌의 교재는 미국교통연구단(TRB)의 국립합동도로연구프로그램(NCHRP)#70 자료를 주로 참고하였다. 이 자료는 부록에 원본 전부를 수록하였다. 다만 아직 이 분야 연구가 미흡한 관계로 본 강좌에서는 재해저감 측면에서 합리적인 침사지 설계 기준을 완전히 제시하지 못하고 있다. 참고로 국립방재연구소의 박무종/강대환 연구팀이 기존의 재해영향평가서 자료 중에서 10개를 선정하여 침사지 소요수면적 산정, USEL 적용, 강우침식도 R의 산정 등에 대해 사례 조사 분석한 결과를 부록에 수록하였다.을 기해야 한다. 있다. 청주권의 무심천도 계획상은 대청댐의 물을 공급 받을수도 있도록 되어 있으나 현실상으로 상수도 원수로서의 공급마저도 매년 심한 원수 수질 문제(5-6월, 10월경의 취수장 부근의 부영양화 현상으로 인한 악취와 물 맛의 문제)를 1984년부터 겪고 있다. 이와 같이 도시권 하천의 수자원은 자연적, 인위적, 경제적, 법적, 제도적 여러 제한 요소로서 특성을 가지고 있으며 이는 날로 심해 가고 있는 실정이다. 그러므로 최적 물관리 시스템의 개발이 새로이 시작하는 수자원 개발 사업에서는 계획 단계에서부터 절실히 요구되는 바이며 기존 시설물의 관리 운영은 과감히 그 운영 관리 기준을 보완 재 정비하여야 할 것이다. 지금까지 대부분의 수자원 종합 개발 계획이 홍수방이나 용수 공급 및 수력 개발 등에 주력하여 왔으나 이제는 보다 더 수자원의 환경 보전적 차원과 도시의 안정적 발달을 위한 지역 및 권역 계획과 연계지워져서 양적인 안정 공급과 더불어 질적인 향상과 연계지워서 경제-사회적 요구에 부응할 수 있도록 도시권의 수자원을 최적 관리할 수 있는 방안을 강구하여야 할 것이다. 이는 각 도시 하천의 수자원의 정량적·정성적인 특성 및 제한 요소를 충분히 감안하여 수요-공급 개념에 의하여 과감히 기존 시설(예: 팔당댐의 운영, 대청댐의 운영 등)의 관리 운영 체계를 개선하여 나가야 할 것이며, 수질 보전적-환경 보전 차원에서 저수관리 체계를 확고히 할 수 있는 방안을 강구하여야 할 것이다.펄스주입법에 의해 증착된 박박은 강유전성 이력을 나타내었다.지역과 비도시지역을 비교하는 조사 연구가 필요하며, 이러한 조사결과를 바탕으로 자녀의 식습관에 대

  • PDF

ACPF 전해환원 실험 및 결과

  • Park, Byeong-Heung;Hong, Sun-Seok;Heo, Jin-Mok;Lee, Han-Su
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.291-291
    • /
    • 2009
  • 한국원자력연구원의 파이로 실험 시설인 ACPF (ACP Facility)에는 공학규모 전해환원 반응기가 설치되어 공정 대용량화를 위한 연구가 수행되고 있다 본 연구에서는 전해환원 공정의 Scale-up을 위해 기존 반응기를 개선하여 전해환원 실험을 수행한 결과를 담고 있다. 장치의 대형화 빛 원격운전성 향상을 위해 기존의 전해환원 반응기의 상부 플랜지는 보다 간단하게 정리되었으며 염 이송에 의한 고온 조건 노출 시간을 줄임과 동시에 염 재사용을 목적으로 상부 플랜지는 이중으로 설계되었다. 따라서, 반응 종료후 전극이 설치된 상부 플랜지를 들어 올림으로서 반응기를 불활성 분위기로 유지하는 동시에 전해환원 금속전환체를 회수 할 수 있도록 반응기가 제작되었다. 또한, 새로운 반응기는 용융염 내의 강제 유동을 위해 아르곤 버블링이 가능하도록 설계 제작되었다. 새로 제작 설치된 전해환원 반응기를 사용하여 산화물 분말을 혼합하여 준비한 모의 사용후핵연료를 사용하여 전해환원 실험을 수행하였다. 그 결과, 산화물이 충진된 음극의 전영역에서 고루 96% 이상의 높은 금속전환율을 얻었으며 시간에 따라 선택된 FP들의 용융염 내 거동을 측정하였다. 실리더 형태의 음극에서 Cs, Sr 등의 원소들이 용융염으로 시간에 따라 용출되는 것을 확인하였으며 동시에 반응기 재질인 Fe 등도 일부 용융염에서 검출되었다. 아르곤 버블링에 의한 강제 유동은 전압 및 전류 거동에는 큰 영향을 미치지 못하였으나 염의 휘발량을 증가시켜 영조성올 변화시키는 것으로 측정되었다. ACPF의 전해환원 실험결과를 바탕으로 반응기를 상부 기체상과 하부 액체상으로 나누어 전산모사를 수행하였다 상부 기체상은 유입되는 아르곤 기체와 발생되는 산소기체의 흐름을 모사하는 결과를 얻었으며 온도 및 산소의 분압을 계산하였다. 하부 액체상에서는 전기장을 모사하여 전류 밀도 등을 3차원으로 모사하였다.

  • PDF

Experimental Study of Flow Characteristics of in the Pump Sump (펌프 흡입부 주변의 흐름특성에 대한 실험적 연구)

  • Byeon, HyunHyuk;Yang, JaeHoon;Yoon, ByungMan;Kim, Seojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.72-72
    • /
    • 2015
  • 최근 이상기후로 집중호우와 강우패턴이 변화하고 있다. 하지만 변화하는 환경을 고려하지 않은 내배수시설 설계로 내수 침수 피해가 증가하여 인명 및 재산 피해가 급증하고 있다. 이에 도시지역의 내수침수에 대한 대책으로 재내지의 초과 우수를 하천으로 강제 배수시키기 위한 빗물펌프장의 역할이 점점 중요해지고 있다. 도심지역의 집중호우에 대응하기 위해서는 빗물펌프장의 목표 배수량을 실제 배수할 수 있는지에 대한 여부가 도시지역의 내수침수를 효율적으로 방어하는데 있어 중요한 요소가 될 것이다. 하지만 현재 빗물펌프장의 설계 시 펌프 흡입부 내 흐름특성을 고려하지 못하고 있어 펌프의 효율에 대한 불확실성이 큰 것이 사실이다. 따라서 펌프 가동 시 흡입부 주변의 흐름특성에 대한 연구가 필요하다. 기존 펌프 흡입부의 실험적 연구에서는 색소를 이용한 vortex의 생성 위치 및 경향을 정성적으로 파악하거나 ADV등의 유속계를 이용하여 흡입부 주변의 흐름특성을 지점별로 분석하는 연구들이 수행되었다. 하지만 빗물펌프장의 펌프 흡입부 주변의 흐름은 펌프 가동에 따라 매우 복잡한 와류가 발생하기 때문에 이를 방지하기 위해서는 정량적인 유속장 분석이 필요하다. 이에 본 연구에서는 비접촉식 유속 측정이 가능하고 유속장 측정이 가능하다는 장점을 갖고 있는 입자영상유속계(PIV: Particle Image Velocimetry)를 이용하여 펌프 흡입부 주변의 흐름특성을 분석하였다. 펌프 흡입부의 흐름특성을 분석한 결과 흡입관 내 유속분포의 편중 현상에 접근유속의 영향이 큰 것으로 나타났다. 또한 흡입유속에 비해 접근유속이 빠른 경우 흡입관 내 유속분포는 상류측에서 횡방향 와류가 발생하여 흡입에 방해가 되는 것을 확인하였고, 하류측으로는 흡입 방향으로 유속이 발생하는 것으로 나타났다. 따라서 향후 펌프 흡입관내 상류측부분의 와류를 감소시키기 위한 연구가 필요할 것으로 판단된다.

  • PDF

Analysis of Dedicated Mission Software Architecture for Unmanned Vehicles for Public Mission (공공임무를 위한 무인이동체 탑재용 임무소프트웨어 구조 분석)

  • Park, Jong-Hong;Choi, Sungchan;Ahn, Il-Yeup
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.3
    • /
    • pp.435-440
    • /
    • 2020
  • The application of the unmanned vehicles in various fields has been attracting attention, and the development of a service utilizing unmanned vehicles has been proceeding. As the service market using the unmanned vehicles rapidly increases, the demand for the development of software for performing the mission with unmanned vehicles is increasing. In particular, as the demand for unmanned vehicle utilization services for public missions such as fire detection, mail delivery, and facility management increases, the importance of developing mission software for unmanned vehicle is increasing. To develop common mission software, architecture design should be made so that unmanned vehicle service provider can easily develop software using reusable libraries or functions through analysis commonly required by various public institutions. In this paper, we discuss the research trends of mission software for public mission unmanned vehicles. In addition, the architecture design of developing formal mission software is proposed. Finally, we propose a data transfer architecture between mission software and data platform.

Comparison of Mechanical Properties on Helical/Hoop Hybrid Wound HNT Reinforced CFRP Pipe with Water Absorption Behavior (CFRP 파이프의 와인딩 적층 패턴 설계 및 HNT 나노입자 보강에 따른 수 환경에서의 기계적 물성 평가)

  • Choi, Ji-Su;Park, Soo-Jeong;Kim, Yun-Hae
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.174-179
    • /
    • 2021
  • Currently, fluid transfer steel pipes take a lot of time and expense to maintain all facilities due to new construction and painting or corrosion and aging. Therefore, this study was conducted for designing a CFRP pipe structure with high corrosion resistance and chemical resistance as a substitute for steel pipes. The helical/hoop pattern was cross-laminated to improve durability, and HNT was added to suppress the moisture absorption phenomenon of the epoxy. The HNT/CFRP pipe was manufactured by a filament winding process, and performed a mechanical property test, and a moisture absorption test in distilled water at 70℃. As a result, the highest bending strength was obtained when the hoop pattern was laminated with a thickness equivalent to 0.6% of the pipe. The 0.5 wt% HNT specimen had the highest moisture absorption resistance. Also, the delamination phenomenon at the interlayer interface was delayed, resulting in the lowest strength reduction rate.