• Title/Summary/Keyword: 시설온실

Search Result 516, Processing Time 0.034 seconds

Development of Raising Device for Greenhouse Column Using a Pneumatic Cylinder (공압실린더를 이용한 온실기둥 상승장치 개발)

  • Lee, Hyun June;Park, Eun Mi;Shin, Dong Chang;Choe, Jung Seob;Kim, Tae Wook
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.206-212
    • /
    • 2018
  • As many consumers prefer good quality food, farms have used various facilities to cultivate products for satisfying their desires. Among them, the most representative facilities are plastic and glass multi-span greenhouse. The height of both plastic greenhouse and glass greenhouse is around three meters high in Korea. As a result, the crop productivity is limited. The solution is to increase the height of the greenhouses to improve the greenhouses' environment. The device for raising columns consists of a stop device, a pneumatic cylinder, and a vertical member. Pneumatic cylinders were designed with a diameter of 160 mm and a stroke length of 50 mm, taking into consideration the safety factor of 1.5. In addition, the air flow was controlled by nozzle to achieve a time of less than 30 seconds per stroke. It was calculated that $21.5L{\cdot}min^{-1}$ of air was needed to complete in less than 30 seconds. Accordingly, the diameter of the nozzle is designed to be 0.5 mm. When the pressure was 0.9 MPa, the average raising force was 13,805N, which was close to the calculated value of 15,612N. The field test results show that any inconsistency in the row columns was not generated. and that it is considered applicable to the actual glass and plastic greenhouses.

Physical Characteristics of Bubble As a Tamping for Greenhouse Keeping Warm (이중피복온실의 보온용 충전재로서 버블의 물리적 특성)

  • 윤남규;김학주;이시영;염성현;남윤일;최상진
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.355-359
    • /
    • 2003
  • 1970년대 백색혁명 이후 급속하게 확산되어온 국내 시설원예산업은 최근 들어 날로 증가하고 있는 난방비에 대한 부담으로 그 경영이 날로 위축되어 가고 있다. 통계자료에 의하면 2001년 우리나라 전체 시설원예 면적 52,135㏊ 중 난방을 하고 있는 시설원예 면적은 12,710㏊로서 약 24%정도를 차지하고 있다. 또한, 시설재배면적의 지역분포를 비교해 보면, 시설채소의 경우 중부 이북지역에 44%, 남부에 56%의 비율로 분포해 있으며, 시설화훼의 경우 중부 이북 58%, 남부 42%인 것으로 보고되었다. 따라서, 국내 시설원예의 분포는 난방비가 많이 소요되는 지역이라도 수도권을 중심으로 유통이나 지리적 면에서 유리한 지역에 시설재배면적이 많이 분포해 있는 소비지중심형 분포임을 알 수 있다. (중략)

  • PDF

A Report on the Control Effects of Automatic Dry Fog Sprayer on Aphids in Greenhouse Crops (시설 온실에서 진딧물에 대한 무인 연무방제기의 방제 효과 보고)

  • Kang, Taek-Jun;Kim, Se-Jin;Kim, Dong-Hwan;Yang, Chang Yeol;Kim, Hyeong-Hwan;Cho, Myoung-Rae
    • Korean journal of applied entomology
    • /
    • v.53 no.4
    • /
    • pp.479-483
    • /
    • 2014
  • The area of greenhouse horticulture has increased dramatically since the early 1990s in Korea. However, area per farmer still very small and diverse pest species occurs in greenhouse abundantly because of its protected condition. To manage pests, farmers use many pesticides frequently. Incessant and improper use of chemicals provoked pesticide resistance in pest and poisoning of farmers. In this study, we investigated the efficiencies of automatic dry fog sprayer for controlling two aphid species, Aphis gossypii and Myzus persicae, in greenhouse horticulture. When doors and side windows were completely closed in automatic dry fog sprayer treatment greenhouse, aphids were controlled similar level with conventional spraying method (percent control: 61.0~94.1%). However, when half of the doors and side windows of the greenhouse were opened, aphids were controlled poorly (percent control: 36.0~54.4%).

Comparison of the CO2 Emissions Estimations among Four Tier Methods for the Facilities from Different Industrial Sectors in Korea (국내 산업 부문에 대한 온실가스 배출량 산정 방법 결과 비교)

  • Kim, Hee Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.195-209
    • /
    • 2012
  • There are four differentiated levels to quantify the amount of greenhouse gas emissions from a facility, which are Tier 1 to 4 based on the IPCC guidelines. In this study, the emission estimates from all tier levels were calculated to compare their total $CO_2$ emission results among themselves for seven facilities, including three sectors of electricity generation, municipal solid waste incineration, and cement manufacturing for three months between February and May 2011. Generally the measured $CO_2$ emissions by Tier 4 were higher than the calculated $CO_2$ emissions by Tier 3, which had been also observed for the power plants in the USA. It was found out that to obtain more reliable estimation for Tier 3, accurate analysis of the composition of the fuel used should be carried out. It was suggested that further refinement on the administrative guidelines be made to make it more robust.

Energy Saving Effects of Carbon Nano Heating Pipe for Heating of Greenhouse (탄소나노히팅파이프를 이용한 온실 난방에너지 절감효과)

  • Paek, Y.;Jeon, J.G.;Yun, N.K.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.107-111
    • /
    • 2011
  • This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were $14.8^{\circ}C$, $13.4^{\circ}C$ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.

Effect of Air-earth Heat Exchange System on Growth of Leafy Lettuce in Greenhouse (온실내 잉여에너지 이용을 위한 지중 열교환 시스템의 상추 재배 효과)

  • Paek, Yee;Jeon, Jong-gil;Yun, Nam-kyu;Kang, Geum-Choon;Lee, Si-Young
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.71-76
    • /
    • 2011
  • Earth to air heat exchangers made by iron, aluminium, copper and poly-ethylene pipe for single greenhouse heating were experimented and blowers. Earth to air heat exchanger was installed by pipelines in earth tube at 70cm depths and air blower was the heating capacity 3kW/h, As the result, Temperature difference due to temperature history of the inlet and outlet air on the various type in earth tube in greenhouse showed that air temperature at the various type in earth tube, comparison tube were make no difference respectively. Under the experimental condition, heat fluxes and heating load were showed 6,800Kcal/h, 19,699kcal/h generally yield of Lactuca Sativa cultured during days of sowing 90day in greenhouse using copper pipe was 170% incleased.

Application of Smart Water Grid Water Circulation System Linked to Power Generation Industry (발전산업 연계 스마트워터그리드 물순환 시스템의 적용방안)

  • Jang, Dong Woo;Choi, Gye Woon;Park, Hyo Seon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.373-373
    • /
    • 2018
  • 화력발전소, 석유화학공단 등 대규모 배출원에서 발생되는 이산화탄소를 활용하여 온실가스의 배출을 줄이고, 경제적 가치를 창출할 수 있는 탄소자원화는 기후변화 대응을 위한 국가전략프로젝트 중 하나이다. 전 세계적으로 탄소자원화 기술은 아직 상용화 단계이지만 최근 강화된 온실가스 감축 의무로 인하여 탄소자원화 시장은 더욱 확대될 전망이다. 화력발전소의 이산화탄소 발생 과정에서 배출되는 수증기는 응축기술을 통하여 새로운 수원으로 활용이 가능하다. 응축된 물의 최적 활용과 사용처 지향적 효율적 물순환을 위한 시설 내 스마트 워터 그리드(SWG) 개념의 물분배 시스템은 발전 산업 내에 탄소자원화의 핵심기술로 사용될 수 있다. SWG는 시설 내 용수공급 관리에서의 관망 운영, 물 수요 관리 등 ICT를 활용한 종합적인 물 분배 시스템으로, 본 연구에서는 SWG 물순환 시스템의 국내외 기술조사를 통해 발전 산업 시설 내에 적용성을 검토하였다. 물의 재이용 시스템을 포함한 SWG 기술, 지능형 관망 운영 기법 기술, 실시간 수질 감시 체계 기술 연구를 기반으로, ICT 기반 용수공급 정보 관리 기술과 수운영 모니터링 기술을 통하여 SWG가 발전 산업 연계 기술로써 적용될 수 있도록 하였다. 본 연구에서 제시된 SWG 시스템을 적용한 산업 인프라를 통하여 산업적 파급 효과를 높이고, 이를 활용한 인력과 비용 절감이 기대되며, 저에너지, 고효율화를 위한 기술력과 글로벌 물 시장진출 경쟁력을 향상시키기 위한 기초연구자료로써 활용이 가능할 것으로 기대된다.

  • PDF

Development of a Control Algorithm for Automatic Ventilation (환기창 자동제어용 제어 알고리즘 개발)

  • 박규식;이기명
    • Journal of Bio-Environment Control
    • /
    • v.6 no.4
    • /
    • pp.242-249
    • /
    • 1997
  • Environmental control operations have been considerably contributed to the reduction of labor cost in both plastic film and glass greenhouses since government supported projects were begun. However, some problems are still remaining on the optimal environmental control and excessive operation due to an inflexible software regulating ventilation gear - reducers. The unadjustable software caused the damage of ventilation system, resulting in heat stresses of crops. This study was performed to develop a ventilation software controlling the vent opening level, opening sequence, based on the wind direction, and control interval according to the difference between ambient and set- up temperatures. The software included a beeper system alarming urgent cases, while a manager was remote from the greenhouse. A compatible hardware with the software was also developed by using a low-cost diffused DSP controller.

  • PDF

Study on the Reduction of NPS Pollution and GHG Emission from Paddies with SRI Methods (SRI 방법을 적용한 논에서의 비점오염원 및 온실가스 저감효과)

  • Park, Woon-Ji;Lee, Su-In;Yun, Dong-Koun;Kim, Gun-Yeob;Choi, Joong-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.440-440
    • /
    • 2012
  • 본 연구에서는 수질관리 및 기후변화(온실가스 저감) 등에 부응할 수 있는 SRI 벼재배 방법을 국내 논에 적용하여 농업비점오염원과 온실가스 저감효과를 측정하고 비교하여 SRI의 환경개선효과를 평가하고자 하였다. 시험포는 대조구인 상시담수처리구(관행, 재식거리 $30{\times}15cm$)와 SRI 물관리 처리구로 조성하였다. 각 시험포에는 관개배수시설 및 관개량을 측정할 수 있는 수도계량기, 유출량 측정을 위한 플륨 및 수위계 그리고 온실가스(메탄 및 이산화질소)를 측정하기 위한 아크릴재질의 Chamber를 설치하였다. 관행 및 SRI 시험포에 이앙할 모의 재배품종으로 오대벼를 공시하고 모든 시험포의 경우 1주당 3-5본씩 기계이앙을 실시하였으며, 물관리를 제외한 시비와 제초 등의 영농관리는 동일하게 수행하였다. 메탄($CH_4$)과 아산화질소($N_2O$)는 주 2회, 오전 9시 12시에 60 mL 주사기로 주기적으로 시료를 채취하여 GC로 분석하였다. 그리고 관개기간동안 관개량, 강우량 그리고 강우 유출량을 측정하고 수질시료를 채취하여 오염부하를 산정하였다. SRI 시험포의 SS, $COD_{Cr}$, $COD_{Mn}$, BOD, TN, TP의 총 오염부하량은 각각 583 kg/ha, 210.8 kg/ha, 70.1 kg/ha, 30.7 kg/ha, 56.1 kg/ha, 3.55 kg/ha로서 관행 시험포의 오염부하량에 비해 27.1~46.0%의 오염물질 저감 효과를 보였다. 그리고 각 시험포별 온실가스 메탄과 아산화질소의 총 배출량을 지구온난화잠재력(GWP)으로 환산하여 이산화탄소($CO_2$) 기준으로 산정한 결과, 관행은 14.2 톤/ha 그리고 SRI 물관리 처리구 4.0 톤/ha로 관행 대비 SRI 처리구에서 71.8%의 온실가스 감축효과를 나타내었다. 따라서 SRI 벼재배기술은 논 비점오염부하 및 온실가스 저감을 위한 효과적인 최적영농관리방법인 것으로 판단된다.

  • PDF