• Title/Summary/Keyword: 시설내부 온도

Search Result 135, Processing Time 0.022 seconds

A Study on the Determinant Factors for Dining at Family Restaurant in Sunchon City (순천시의 훼밀리레스토랑을 이용하는 고객들의 외식결정요인에 관한 연구)

  • 강종헌
    • Korean journal of food and cookery science
    • /
    • v.17 no.6
    • /
    • pp.571-582
    • /
    • 2001
  • The purpose of this study was to identify important selection attributes of customers for dining at family restaurants, and the determinant and predicting factors in customers' intentions of revisiting. A closed-ended questionnaire was used, and a systematic sampling approach was employed to survey a sample of customers in family restaurants. A total of 124 questionnaires were used for analysis among 300 distributed. Multivariate analysis(factor and regression analysis) was performed for 19 selection attributes measured on a five-point scale. A four-dimensional structure(harmonized decoration consistent service, valuable food, and attractive facility) was established from 19 selection attributes. The results of the study showed that three dimensions were significantly related with the customer's intention of revisiting. The dimension of consistent service had the greatest impact on customers' choice. It was clear that a family restaurant manager's emphasis on only one dimension to attract customers might not be as effective as applying a multi-dimensional strategy.

  • PDF

Effect of Using Burn-type CO2 Generators When Cultivation Strawberry in a Greenhouse (딸기재배 시 연소식 탄산가스 발생기 이용 효과 구명)

  • Lee, Jae Han;Lee, Jung Sup;Park, Kyoung Sub;Kwon, Joon Kook;Kim, Jin Hyun;Lee, Dong Soo;Yeo, Kyung Hwan
    • Journal of Bio-Environment Control
    • /
    • v.27 no.2
    • /
    • pp.111-116
    • /
    • 2018
  • This study were carried out to evaluate the efficiency of using burn-type $CO_2$ generators in greenhouse for cultivation 'Seolhyang' strawberry ($Fragaria{\times}ananassa\;Duch.$) during winter season. The concentration of $CO_2$ was 200 to $600{\mu}mol{\cdot}mol^{-1}$ in the control, and 800 to $1,100{\mu}mol{\cdot}mol^{-1}$ in using burn-type $CO_2$ generator between 6 and 11 hours. At other times, it was observed that at similar concentration in the control and using burn-type $CO_2$ generator. Measured greenhouse air temperature inside the of using burn-type $CO_2$ generator was $2{\sim}3^{\circ}C$ higher than the control at 6 ~ 10 am. There was no temperature difference between treatments after 11 o'clock. Plant height, leaf length, leaf width, root diameter, fresh weight, and dry weight were not different between treatments. The marketable yield (kg/10a) of using burn-type generator were 4,131 kg, which was 519 kg higher than the control. Therefore, the total fruit yields increased 17% compared to the control.

Beneficial Effect of Heat Fans on Quality and Yield of Korean Melon Cultivated in Greenhouses at Winter Season (히터팬 처리가 저온기 하우스 참외의 품질 및 수량에 미치는 긍정적 영향)

  • Shin, Yong Seub;Lee, Ji Eun;Oh, Su Whan;Cheung, Joung Do;Sohn, Hyoung Rac;Do, Han Woo;Kim, Mi Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.188-193
    • /
    • 2017
  • The purpose of this study was to investigate the changes of environmental conditions and the quality and yield of melon fruit by heat fan operation in greenhouses at winter season. The average daily temperature inside the tunnels during January 1 to 31, 2017 was $0.9^{\circ}C$ higher than that of the control $17.8^{\circ}C$. The air flow rate of heater fan treatment was 4.8 times higher than the control (untreated $0.05m{\cdot}s^{-1}$) at 20cm above the ground where the korean melon grew. The temperature of the heater pan was $5.6^{\circ}C$ higher than that of the untreated at $35.3^{\circ}C$ and the relative humidity was 8.1% lower than that of the untreated at 39.1%. The flowering rate of the heater fan treatment was 96%, 5% higher than the control. The number of first harvest days of heater fan treatment was shortened by 4 days than that of untreated treatment. Fruit quality and marketable fruit yield increased by 3.4% and 38% compared to untreated respectively, the heater fan treatment increased the temperature inside the greenhouse and air flow rete, which were beneficial for growing the korean melon in greenhouses at winter season.

Analysis on the Characteristics of Heat Wave Vulnerable Areas Using Landsat 8 Data and Vulnerability Assessment Analysis (Landsat 8 영상과 취약성 분석을 활용한 폭염재해 취약지역의 특성분석)

  • KIM, Ji-Sook;KIM, Ho-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Cities are highly susceptible to disasters due to concentration of population and infrastructure and intensive land use, and there are various factors that affect vulnerability according to regional characteristics. This study analyzed the vulnerability of the heat wave and the surface temperature extracted from Landsat 8 satellite data. Areas with high surface temperature and with high vulnerability did not match. This study overlaid the results of vulnerability analysis and the land surface temperature(LST) in order to identify causes of vulnerability. The results showed that some areas within high-density commercial and semi-residential areas were the most vulnerable, with climate exposure factors, the ratio of the vulnerable populations and residential defective areas being the main causes. Accordingly, alternatives such as green space and residential environmental improvement could be suggested. Various policies for reducing and adapting to heat wave have been established and implemented. However, it is necessary to examine the regional and spatial characteristics of the city, to accurately diagnose the cause of the heat wave, and to prepare appropriate long-term alternatives accordingly.

Veriations of Carbon Dioxide Concentration in a Strawberry Greenhouse Using Dry ice (드라이아이스를 이용한 딸기재배 온실의 이산화탄소 농도변화)

  • Paek, Yee;Kang, Suk-Won;Jang, Jae-Kyung;Kwon, Jin-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.182-188
    • /
    • 2020
  • This study aimed to collect the carbon dioxide generated as a by-product from petrochemicals and liquor factories and use it in a crop breeding greenhouse. This was applied mainly to the storage of dry ice and the supply of carbon dioxide to achieve this target. Dry ice has a strong cooling effect because CO2 becomes a solid or gas at temperatures and pressures below the triple point, and the solid sublimes at -78.5℃ and atmospheric pressure. The consumption of dry ice according to temperature was 0.983kg/day, 2.358kg/day, 5.102kg/day, and 7.035kg/day when the temperature was 5℃, 10℃, 15℃, and 20℃, respectively, which corresponded to 1,102ppm, 1,481ppm, 1,677ppm, and 1,855ppm. Dry ice consumption in the test greenhouse decreased by approximately 0.9kg/h, and the CO2 concentration in the greenhouse at 9 a.m., before supplying dry ice increased to 517ppm, 1,519ppm at 10 a.m., 1,651ppm at 11 a.m., and 1,651ppm at 12 p.m., before maintaining this level of activity. Overall, this study attempted to contribute to increasing farm income by deriving the supply conditions through an expansion of the supply of carbon dioxide gas for crops.

Effect of Rainwater Sprinkling System Utilization for Reducing Heat Stress in Milking Cows during Intense Heat Time (폭염시 착유우 고온스트레스 경감을 위한 빗물관수시스템 이용 효과)

  • Choi, Dong-Yoon;Cho, Sung-Back;Park, Kyu-Hyun;Yang, Seong-Hak;Hwang, Ok-Hwa;Kwag, Jung-Hoon;Jeong, Kwang-Hwa;Song, Jun-Ik;Yoo, Yong-Hee;Ahn, Hee-Kwon
    • Journal of Animal Environmental Science
    • /
    • v.18 no.sup
    • /
    • pp.21-28
    • /
    • 2012
  • Since the temperature during summer is higher than the temperature which is suitable for milking cows, high temperature stress have severely affected dairy farmers due to decreased milk production. This study was carried out to investigate the effect of rainwater sprinkling system for reducing heat stress in milking cows during intense heat time. Treatment conditions were divided into 2 types ; No rainwater sprinkling (T1) and Rainwater sprinkling (T2). Temperature in the milking cow shed, feed intake, milk yield, respiration rate and rectal temperature were measured to investigate the effect of hot environment on the physiological, productive responses in milkig cows. The results obtained are summarized as follows : The daily milk yields were 24.5 and 27.4 kg per head in T1 and T2 during experimental period. The respiration rate was significantly higher in T1 than those of T2. The rectal temperature in T1 ($40.6^{\circ}C$) was higher than those of T2 ($39.8^{\circ}C$). It was suggested that rainwater sprinkling system installed in the dairy cow shed was effective means to reduce heat stress of milking cow.

Effect of Growing Part Following Local Heating for Cherry Tomato on Temperature Distribution of Crop and Fuel Consumption (방울토마토 생장부 추종 국소난방이 군락 온도분포 및 연료소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Lee, Tae Seok;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.217-225
    • /
    • 2015
  • Local heating system providing hot air locally to growing parts including shoot apex and flower cluster which were temperature-sensitive organs of cherry tomato was developed to reduce energy consumption for greenhouse heating without decline of crop growth. Growing part following local heating system was composed of double duct distributer which connected inner and outer ducts with hot air heater and winder which moved ducts up and down following growing parts with plant growth. Growing part local heating system was compared with conventional bottom duct heating system with respect to distributions of air and leaf surface temperatures according to height, growth characteristics and energy consumption. By growing part local heating, air temperature around growing part was maintained $0.9{\sim}2.0^{\circ}C$ higher than that of lower part of crop and leaf surface temperature was also stratified according to height. Investigations on crop growth characteristics and crop yield showed no statistically significant difference except for plant height between bottom duct heating and growing part local heating. As a result, the growing part local heating system consumed 23.7% less heating energy than the bottom duct heating system without decrease of crop yield.

Assessment of Dust Reduction in the Enclosed Pig Building by Spraying Method with Liquid Additives (액상 첨가제 살포 방법에 의한 밀폐형 돈사에서의 분진 저감 평가)

  • Kim, K.Y.;Ko, Han-Jong;Kim, C.N.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.97-104
    • /
    • 2008
  • Appropriate air quality in the pig building is essential to prevent farmers' health as well as to increase pig performance. This on-site experiment was conducted to assess dust reduction efficiencies of several liquid additives with spaying method in the enclosed pig building. The mean reduction rate of total dust only after spray was approximately 30% for all the treatments compared to initial level before spraying additives, which was found to reduce the initial level of total dust significantly (p<0.05). The mean reduction rate of all the treatments at 1hr after spray was about 24% which was 6% lower than only after spray. Since 3hr after spray, however, total dust level were fluctuated variably for all the treatments besides application of the soybean oil. Based on this result, effect of soybean oil on dust reduction in the enclosed pig building was most prominent among liquid additives evaluated in terms of efficiency and duration.

  • PDF

Effect of Pile Temperature Control on Changes of Nutritional and Microbilological Parameters of Composted Poultry Waste (육계분의 콤포스터 처리시 내부온도 조절이 생산물의 영양학적, 미생물학적 성상에 미치는 영향)

  • Kwak, Wan-Sup;kim, Tae-Gyu;Kim, Oun-Hyun;Kim, Chagn-Won
    • Journal of Animal Environmental Science
    • /
    • v.2 no.2
    • /
    • pp.147-154
    • /
    • 1996
  • In an attempt to recycle as feed or fertilizer, broiler litter containing rice hull was manually composted under the control of peak temperature of piles(uncontrolled or controlled below $70^{\circ}C$ or below $60^{\circ}C$) in each of three $1.0\;{\times}\;1.0\;{\times}\;1.2m$ dimensional facilities. Changes of nutritional and microbiological parameters were evaluated throughout the 8 weeks of processing period. The initial content of crude protein(29.6%) decreased to 17.8% after 8 weeks of composting. The rapid nitrogen(N) loss observed in the early phase was attributed mainly to non-protein-N(NPN) loss. The initial content of ash(19.1%) increased to $26{\sim}29%$ after 8 weeks. For toxic heavy metals, Cr, Pb, and Hg contents of final composts were far less than the maximum tolerance levels allowed in food or compost. Bacterial growth was rather depressed until the second week, increased thereafter, and reached to peak($10^{12}cfu$ level) at the 4th week of composting. With composting, actinomycetes were active at the level of $10^7\;to\;10^9$. Fungi were active during the first to third week of composting. In general, control of pile temperature below $70^{\circ}C$ did not remarkably alter the nutritional and microbiological parameters of broiler litter compost, compared to that of pile temperature below $60^{\circ}C$. Further researches on prevention from the rapid loss of NPN in the early phase of composting are required for more effective recycling of broiler litter.

  • PDF

An Analysis of Luminance and Chromaticity on Outdoor Lighting of Historic Buildings -focused on Namdaemun and Kwanghwamun- (휘도와 색도측면에서 본 역사적 건축물의 야간경관조명 분석 -남대문과 광화문을 중심으로-)

  • 안현태;김정태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.36-43
    • /
    • 2001
  • Recently, outdoor lighting of buildings has bemIre activated in national level of Korea. Therefore, this study aims to analyze the outdoor ljghting effect of historic buildings with particular reference to two traditional gates architecture - Namdaemtul and Kwanghwamun For the purpose, luminance and chromaticity of outdoor lighting are measured. The results of the study are as follows; $\circled1$ Outdoor lighting of the historic buildings were mainly illuminated by the floodlights. In addition, up-lighting and accent lighting were locally used. $\circled2$ Basements and rooflines were specially emphasized, and they represented the night image of historical buildings. $\circled3$ Chromaticity distribution of historical building was wlute during the day. However, it was yellow dL1Jing the night due to the color and color temperature of outdoor lighting.ghting.

  • PDF