• Title/Summary/Keyword: 시상수

Search Result 316, Processing Time 0.032 seconds

Transient Response of an Electrorheological Fluid in Shear Flow (전단 유동 하에서 전기유변유체의 과도응답 특성)

  • Choi, Byung-Ha;Nam, Yun-Joo;Park, Myeong-Kwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.411-417
    • /
    • 2009
  • The transient shear stress response of an electrorheological fluid is investigated experimentally. The characteristic time constants of an electrorheological fluid sheared between two concentric cylinders were obtained under various electric field strengths and shear rates. Also, two experimental modes are adopted to investigate the effect of the shear flow on the dynamic behavior of the fluid; one is that the electric field is induced before shearing, and the other is the electric field is induced after shearing. From the difference in the response time between two modes, the cluster formation time were obtained. The response times were decreased with the increase of the shear rate, irrelatively of the electric field strength. The cluster formation time were monotonically increased with increase of shear rate, and thereafter, were converged with a certain value.

A Study on the Pressure Control Characteristics of ON/OFF 3-way Solenoid Valve Driven by PWM Signal (개폐식 3방향 전자밸브의 펄스폭 변조 구동에 의한 압력제어 특성에 관한 연구)

  • Jeong, Heon-Sul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.485-501
    • /
    • 1997
  • Pressure control is possible driving a simple ON/OFF 3-way valve of hydraulic servo system by pulse width modulation signal. But the pressure varies according to the duty ratio and carrier frequency and repeated on-off action induces pressure fluctuation. So equations for mean pressure and ripple amplitude are theoretically derived as a function of on/off time, the system parameters which decide the pressure characteristics are arranged and they are verified by experimental study. As the result selection criteria for the major design parameters are established and the basic strategy to suppress the unnecessary fluctuation can be provided for a hydraulic pressure control system using these type of valves.

NUMERICAL STUDY OF TRANSIENT CONJUGATE HEAT TRANSFER IN A MICRO-CHANNEL SUBSTRATE (마이크로채널 기판에서 비정상 복합 열전달의 수치적 연구)

  • Lee, H.J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.87-92
    • /
    • 2012
  • A numerical study of transient conjugate heat transfer on micro heater in a micro-channel substrate under pulsed heating was conducted. It was found that the time constant is not affected by the pulse heating magnitude at same operating condition. Furthermore, the time constant increases with low substrate thermal diffusivity, low Reynolds number, and large channel diameter. Since the time constant is a dominant parameter to characterize transient heat transfer, it should be considered for transient convective heat transfer coefficient.

Design of DC-DC Converter for Fuel Battery Charger for Mobile Phone (휴대폰용 연료전지 배터리 충전기 DC-DC 컨버터 설계)

  • Im, Seung-Ryul;Kim, Jong-Soo;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.260-261
    • /
    • 2007
  • 본 논문에서는 휴대폰 배터리의 충 방전 특성을 고려하여 연료전지를 이용한 휴대폰 배터리 충전기용 회로 및 제어 방법을 설계한다. 배터리의 충전 시상수를 저항과 커패시터로 설계하고 시뮬레이터를 구성한다. 또한 배터리의 자연방전에 따른 재충전을 수행하는 보상충전을 위하여 히스테리시스 제어를 적용하였고 시뮬레이션을 통해 충전기 동작을 확인한다.

  • PDF

Rotor Time Constant Compensation of Induction Motor by Estimating Deviation Angle (회전자 자속 이탈각 추정을 이용한 유도전동기의 회전자 시상수 보상)

  • Cha, Young-Kil;Jung, Jong-Jin;Kim, Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.264-267
    • /
    • 1995
  • In indirect vector control, if the value or the rotor tine constant used in slip calculation is different from the actual rotor time constant because of the temperature rising and flux saturation level, model flux angle and actual flux angle is different so that the transient and steady state response is degraded. In this paper, flux deviation angle is calculated by using actual torque and reference torque, and this flux deviation angle is summed to slip angle, therefore rotor flux angle is always accurate and indirect vector control is satisfied.

  • PDF

Fuel cell stack modeling considering dynamic characteristic of stack voltage according to load variation (부하변화에 따른 스택전압 과도특성을 고려한 연료전지 모델링)

  • Ko, Jeong-Min;Kim, Jong-Soo;Choe, Gyu-Yeong;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1102-1103
    • /
    • 2008
  • 본 논문에서는 연료전지의 정특성과 전압의 과도 특성을 고려한 연료전지 모델링을 하였다. 전기화학적 방정식으로부터 연료전지의 정특성을 모델링하였고, 실험결과 파형을 분석하여 RC 시상수를 이용하여 과도특성을 모델링하였다. 모델링은 Matalab Simulinik를 이용하여 이루어졌으며, NEXA system을 이용하여 실험한 결과와 비교, 분석하여 이 모델링의 유용성을 검증하였다.

  • PDF

Development of Gasoline Direct Swirl Injector II (직접분사식 가솔린 선회분사기 개발에 관한 연구 II)

  • 박용국;이충원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.76-84
    • /
    • 2001
  • Generally fuel injection system using solenoid have some problems between control signal and mechanical movement like as time lag. Main purpose of the present study is to help the design optimization of GDSI for real engine application. We have adopted two different solenoid driving circuit, namely saturation and pick-hold type and have investigated experimentally the current, needle force, needle opening duration and injection quantity. The pick-hold type driving circuit surpassed a saturation type in the response time and pression control of injection quantity. Accordingly, Using characterization data of operating factors such as time constant, driving force and so on, can be evaluated and adjusted to obtain an optimum injector performance.

  • PDF

Design of a Small-Scale Motor-Generator System for a Large Wind Turbine (대형 풍력발전기용 소형 모터-발전기 시스템 설계)

  • Lim, Chae Wook
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.48-52
    • /
    • 2017
  • Small-scale motor-generator sets have been used in laboratories for verification of real large wind turbines whose rated power are more than 1 MW. In this paper, a result of designing a small-scale motor-generator system, which is composed of motor, gear box, flywheel, and generator, is presented in the aspect of speed response. Design objective is to make a small-scale motor-generator system have the same time constant and optimal tip speed ratio region as a real MW wind turbine. A small-scale 3.5 kW motor-generator system for emulating response of a 2 MW wind turbine is considered and designed.

고양이 시상하부의 뇌실옅핵과 시각교차위핵의 Vasopressin과 Oxytocin 신경원에 대한 면역조직화학적 연구

  • 정경아;박래백
    • The Korean Journal of Zoology
    • /
    • v.37 no.1
    • /
    • pp.88-96
    • /
    • 1994
  • 고양이의 시상하부내 SON과 PVN에서 VP분비신경원과 OT분비신경원의 형태와 분포를 관찰하기 위해서 면역조직화학적 반응을 시행하였다. 광학 및 전자 현미경적 관찰에 의하면 VP분비신경원과 OT분비신경원의 형태 차이는 없었다. 이들의 형태는 방추형, 타원형 그리고 원형이었으며 크기는 25-40mm으로 나타났다. SON은 시삭위에 능형의 형태로 나타나고 OT분비신경원과 VP분비신경원의 비율은 1:2.4이며 PVN은 제3뇌실을 따라 삼각형 모양으로 나타나고 VP분비신경원과 OT분비신경원의 비율은 1:1.6으로 나타났다 전자현미경적 관찰에 의하면 VP분비신경원과 OT분비신경원에서 과립형질내세망, 사립체, 골지장치, 그리고 미세소관 등이 특히 잘 발달되어 있음을 관찰할 수 있었다.

  • PDF

Control characteristics of a refrigerant compressor test facility (냉매압축기 성능시험장치의 제어 특성)

  • Lee, J. Y.;Lee, D. Y.;Kim, K. H.;Nam, P. W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.46-51
    • /
    • 1999
  • This paper describes the control charcteristics of thermal/flow systems. In thermal/flow systems, the transport lag plays as a dead time causing a deterioration of the controllability. Besides this, such many parameters including the temperature, pressure, and flow rate affect the system response that a control scheme which can deal with multi-input is required. Particularly in a refrigerant compressor test facility, the evaporator and condenser interact each other so that the change in the evaporator pressure cause the condenser pressure to change or vice versa. Therefore, to control the evaporator pressure, not only the cooling water flow rate in the evaporator but also the coolant flow rate in the condenser is considered. Meanwhile, the conventional PID controllers, which is suitable for a single input system, shows a large overshoot for a disturbance input. In this work, the predictive control scheme is introduced and its applicability is discussed for thermal/flow systems.

  • PDF