• Title/Summary/Keyword: 시력보정용 안경

Search Result 13, Processing Time 0.028 seconds

The Sight Corrective Spectacle Frames as a Medical Devices (의료기기로서의 시력보정용 안경테)

  • Kim, Sang-Hyun;Lim, Yongmoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.143-149
    • /
    • 2007
  • We have compared and analyzed the definition of medical devices, classification, who treats, controls and sales the spectacle frames in South Korea, USA and European Union in this paper. South Korea classifies the spectacle frames as an industrial products while EU and USA regards it them as the medical devices. Sunglasses are industrial products in South Korea and EU but they are still the medical devices in USA. Assignment of spectacle frames and sunglasses as an industrial products could bring into several problems. Restricted classification of medical devices on spectacle frames and sunglasses will resolve the problem mentioned.

  • PDF

The Problems of Army Supply System for Eyeglasses and Improvement Plan (군의 안경 보급체계 문제점과 개선방안)

  • Kim, Sanghyun;Shim, Hyun Sug;Kim, Dae Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.307-312
    • /
    • 2010
  • Purpose: In this paper, we have dealt with problems of army supply system for eyeglasses and improvement plan. Methods: We collected the latest service request of MND (Ministry of National Defence) and case of U.S. Army and analyzed the data. Results: We treated contents, construction methods and plans for efficient use of vision DB (database) for Korean Army. We suggested several alternative proposal for eyeglasses supply system which made possible quicker delivery of eyeglasses to the soldiers and increase satisfaction. Conclusions: The Korean Army must construct vision DB to service high quality vision service to the solider. It is urgent that the Korean Army set up a unit to take charge of vision management and service. And the Korean Army need to upgrade supply system for eyeglasses.

A Comparative Study of Ophthalmic Spectacle Lenses Standards (시력보정용 안경렌즈의 규격에 관한 비교 고찰)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.397-415
    • /
    • 2004
  • This study surveyed differences among KS, ISO, JIS and ANSI ophthalmic spectacle lenses standards. These standards applied to several lenses that were in common currency and we checked over problems and improvements in KS. KS corresponded to ISO, for the most part, and ANSI, partly. But terms, definitions, progressive power lenses standards, UV transmittance and base curves clauses did not exist in KS. There was no differences between nominal data and actual data in important clauses estimation-minimum requirements on refractive power, tolerances on the size of lenses, material and surface quality. But tolerances of thickness, base curves, UV and visible transmittance values were not existing, there were differences among several ophthalmic spectacle lenses in the test of these clauses. These requirements will be needed for better and more comfortable vision.

  • PDF

Development of Gas-mask Spectacles (방독면 안경 개발)

  • Lee, Jeung-Young;Parkm Jeong-Sik;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.9-12
    • /
    • 2008
  • Purpose: Current gas-mask is very uncomfortable structure for spectacles wearer. Improving this problem can aid military men and firemen to protect themselves and rescue other person. Methods: we changed the structure from dual type of outward lens and inward lens into a single type structure. we attached acrylic frame to gas-mask instead of outward lens and protected the gas inflow by shutting the gab of lens and frame using silicon shield, and made the frame "S" style for removing astigmatism and maintaining of vertex distance. Results: It was possible to correct visual acuity and gas shield, and could changed the lens like a common spectacles. The new type of gas-mask spectacles could remove 0.53D~1.78D astigmatism occurred from the slant of eyesight and lens surface, 0.07D~0.66D overcorrection occurred from short vertex distance, and 0.1D~0.3D astigmatism occurred from pantoscopic angle. Conclusion: Because new type of gas-mask spectacles had clear visual field, it was expected to improve fighting power and rescue ability.

  • PDF

Automatic Defect Inspection with Adaptive Binarization and Bresenham's Algorithm for Spectacle Lens Products (적응적 이진화 기법과 Bresenham's algorithm을 이용한 안경 렌즈 제품의 자동 흠집 검출)

  • Kim, Kwang Baek;Song, Dong Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1429-1434
    • /
    • 2017
  • In automatic defect detection problem for spectacle lenses, it is important to extract lens area accurately. Many existing detection methods fail to do it due to insufficient minute noise removal. In this paper, we propose an automatic defect detection method using Bresenham algorithm and adaptive binarization strategy. After usual average binarization, we apply Bresenham algorithm that has the power in extracting ellipse shape from image. Then, adaptive binarization strategy is applied to the critical minute noise removal inside the lens area. After noise removal, We can also compute the influence factor of the defect based on the fuzzy logic with two membership functions such as the size of the defect and the distance of the defect from the center of the lens. In experiment, our method successfully extracts defects in 10 out of 12 example images that include CHEMI, MID, HL, HM type lenses.

Effects of Wearing Corrective Glasses for Presbyopia on Age-related Hyperopic Shifts and Reading Addition (노안보정용 안경 착용이 연령관련 원시화와 근용가입도 변화에 미치는 영향)

  • Lee, Koon-Ja;Kim, Jin-Han;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.65-73
    • /
    • 2009
  • Purpose: This study was conducted to investigate the changes in distance refractive power and reading addition that occur after wearing corrective glasses for prebyopia. Methods: The subjects aged 42 to 75 years who had no ophthalmologic diseases and did not undergo cataract or retina surgery, had a corrected visual acuity of 20/20 and did not have a previous history of wearing corrective glasses for presbyopia. These subjects were divided into 3 groups: the control, reading spectacles and multifocals wearing group and they were measured for distance refractive power and reading addition at their visit. The maximum follow-up period was 73 months. Results: As for distance refractive power, the power tends to shift to hyperopia depending on age (r=0.486, p<.001) and 50.0% of the subjects increased plus power during this study period. Plus power Increments per year in distance refractive power in the reading spectacle wearing group were significantly different with control and multifocals wearing group (p<.05). On the other hand, the multifocals wearing group's increments were not different with control. Increments in reading addition were also increased in the reading spectacles group than in the control and multifocals wearing groups (p<.05). Conclusions: The age related hyperopic shift could be occurred in the elderly people, routine refraction is mandatory. And reading spectacles could induce an age related hyperopic shift and the additional need for reading addition that the prescription of multifocals may reduce changes in distance refractive power and reading addition.

  • PDF

A Cracks Detection of Spectacle Lens using Fuzzy Method (퍼지 기법을 이용한 안경 렌즈의 흠집 검출)

  • Choi, Kyoung-Yeol;Lee, Won-Joo;Kim, Kwang-Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.171-174
    • /
    • 2010
  • 본 논문에서는 렌즈의 흠집을 추출할 수 있는 퍼지 기법을 이용한 렌즈 흠집 검출 방법을 제안한다. 제안된 방법은 렌즈 영상을 그레이 영상으로 변환한 후, 캐니 마스크를 이용하여 렌즈의 경계선을 추출한다. 추출된 렌즈의 경계선에 대해 평균 이진화와 모폴로지를 이용하여 렌즈 경계선을 보정한다. 렌즈 경계선이 보정된 영상에서 Seed Fill 알고리즘을 적용하여 렌즈의 내부 영역만을 추출한다. 추출된 렌즈의 내부 영역에 해당하는 원 영상에서 소벨 마스크를 적용하여 렌즈 내부 영역의 에지를 추출한다. 렌즈 내부 영역에서 추출된 에지 객체들의 정보를 이용하여 흠집과 비흠집을 분류하는 퍼지 기법을 적용하여 흠집 영역을 추출한다. 본 논문에서 제안된 렌즈의 흠집 검출 방법의 성능을 평가하기 위해 CHEMI, MID, HL, HM 시력 보정용 렌즈를 대상으로 실험한 결과, 제안된 방법이 흠집을 효과적으로 검출하는 것을 확인하였다.

  • PDF

The Research on the Optical Reliability of Spectacle Lens in Korea (국내 안경렌즈 광학적 요소 신뢰성 조사)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Purpose: This study is to evaluate reliability of geometrical optics properties of spectacle lenses by using ISO and the medical instrument standard of KFDA, which are being sold in Korea. Methods: We used samples of three hundred and ninety eight spectacle lenses of eight company in total. Refractive indices of each samples which were used in experiment were classified into three groups of medium index (1.55~1.56), high index (1.60~1.61) and extra high index (1.67). Results: Conformity of refractive power was 81.61% in total spectacle lenses. The results showed that thickness conformity 90%, appearance conformity 85.18%, size conformity 96.23% and optical center point conformity 99.50% in total. Conclusions: We found that they deviated from the permitting value in many spectacle lenses on refractive power. The results of errors on prism power, surface inspection and optical center point showed small values in total products. In experiment of lens size and thickness, the bulk of indication rates and conformities of samples deviated from the permitting errors.

  • PDF

The Study about Measuring Method in Radius of Eyeglasses Lens Curvature by using Keratometer (각막곡률계를 이용한 안경렌즈 곡률반경 측정방법에 관한 연구)

  • Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.127-133
    • /
    • 2012
  • Perpose: The aim of this study is to investigate the measuring method in radius of eyeglasses lens curvature by using keratometer in noncontact method. Methods: A trial lens for vision test in diopter range from -9.00 D to -11.50 D were attached in front part of keratometer, after that we set eyeglasses lens at the place where eyeglasses lens is apart about 25 cm from front position of keratometer. We measured the radius of curvature from observation of clear mire image while the position of eyeglasses lens is changed in a small quantity. After that, we made some formulas for compensation of radius of curvature by using spherometer. Results: The radius of curvature was successfully measured by keratometer with trial lens in front part of it. The measured radius of curvature was changed to compensation value using spherometer data, and the 5 kind of linear equation to make compensation value was made. Any kind of lenses measured by using keratometer that trial lens was attached in front part of it, after that it was confirmed that the result of calculation from line equation is exact in error ratio below 3.5%. Conclusions: It was confirmed that radius of eyeglasses lens curvature can be measured by using keratometer by noncontact method, and the accuracy is higher than "lens measure".

Optical Models of the Finite Schematic Eyes for Presbyopia (노안을 위한 정밀 모형안 설계)

  • Baarg, Saang-Bai
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.439-447
    • /
    • 2008
  • There is a need for a finite schematic presbyopic eye that models vision and image quality under various conditions such as cataract or refractive surgery, as well as near vision corrections with an ophthalmic lens or contact lens. Using recently measured biometric data of presbyopic eyes, new model eyes were designed that are optically and anatomically close to real eyes. The parameters changing significantly with age were incorporated into models for four different age groups. The new model eyes have alpha angle, decentered pupil, aspheric GRIN lens and aspheric retinal surface. It is likely that the new finite presbyopic model eyes will be useful for designing visual instruments such as low vision aids, PALs, IOL and contact lenses, and for the clinical prediction of the retinal image quality of a presbyopic patient.