• Title/Summary/Keyword: 시동/정지

Search Result 51, Processing Time 0.023 seconds

Study on the Expansion Technique of Compressor Characteristic Map to Sub-Idle Range (저속영역으로의 압축기 특성맵 확장기법 연구)

  • Jun, Yong-Min;Choi, Jong-Su
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.5
    • /
    • pp.54-59
    • /
    • 2011
  • Reliable starting capability of a gas turbine engine calls the engine industry's attention recently. So far the gas turbine engine performance researches have focused on the range between idle to Max rpm, but recent attention on the starting has brought interests in the range of "Sub-dile". As component characteristic maps are essential for the starting research, various kinds of studies have been doing and proposing ways to expand the existing maps toward sub-idle range. In this paper, previous studies were discussed and a new method suggested and validated.

Study on the Expansion Technique of Compressor Characteristic Map to Sub-Idle range (저속영역으로의 압축기 특성맵 확장기법 연구)

  • Jun, Yong-Min;Lim, Byung-Jun;Rhee, Dong-Ho;Choi, Jong-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.694-699
    • /
    • 2010
  • Reliable starting capability of a gas turbine engine calls the engine industry's attention recently. So far the gas turbine engine performance researches have focused on the range between idle to Max rpm, but recent attention on the starting has brought interests in the range of "Sub-dile". As component characteristic maps are essential for the starting research, various kinds of studies have been doing and proposing ways to expand the existing maps toward sub-idle range. In this paper, previous studies were discussed and a new method suggested and validated.

  • PDF

회전기계의 진동평가 및 설비법(I)

  • 양보석
    • Journal of the KSME
    • /
    • v.27 no.6
    • /
    • pp.478-488
    • /
    • 1987
  • 회전기계의 고성능, 고속화에 따라 베어링 유막특성에서 자려진동이 발생하기 쉬운 조건이 되고 더욱이 고압화에 의해 자동유체로부터 불안정한 힘이 증대하게 되었다. 또한, 고속화에 의해 계의 운전속도가 1차 위험속도 이상으로 되어 시동, 정지시에 위험속도를 통과하여야 하며, 고차 위험속도에서의 공진가능성 등을 충분히 검토하여야 한다. 따라서 종래의 실제방법만으로는 회전기계의 진동문제에 충분히 대처할 수 없는 상태이다.

  • PDF

Bridge Pier Scour Protection by Sack Gabions (돌망태에 의한 교각세굴 방지)

  • Yun, Tae-Hun;Kim, Dae-Hong;Lee, Ji-Song
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.725-731
    • /
    • 2000
  • Experimental studies were conducted in a clear water condition to investigate the functioning of a sack gabion as a scour countermeasure at bridge piers. For different sizes of fill materials of sack gabions no difference was observed in the initial movement of sack gabions. Significant factors on the dislodging of sack gabions are approaching flow depth and velocity, pier width, and thickness and length of sack gabions. It was observed that the stability of the sack gabions is increased in a collective body of riprap stones than the placement of individual riprap stone. The length of a sack gabion has significant effect on its initial movement and the stability of a sack gabion was found to be increased by lengthening the length of gabions. The experimental results were used to derive formulas sizing gabions for scour protection at bridge piers. piers.

  • PDF

Motion Control of Non-Contact Start/stop Hard Disk Drive Using Shape Memory Alloy Actuator (형상기억합금 작동기를 이용한 비접촉 시동 및 정지형 하드디스크 드라이브의 운동제어)

  • Im, Su-Cheol;Park, Jong-Seong;Choe, Seung-Bok;Park, Yeong-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.196-202
    • /
    • 2002
  • In this work, we propose a new type of HDD suspension featuring shape memory alloy (SMA) actuator in order to prevent the contact between the slider and disk. The principal design parameters are obtained from the modal analysis using finite element analysis, and then the dynamic model is established to formulate the control scheme for Non-Contact Start/stop mode drive. Subsequently, a robust H$\_$$\infty$/ control algorithm is designed by integrating experimentally-Obtained SMA actuator dynamics to the proposed HDD suspension system. The controller is empirically realized and control results for the load/unload profiles are presented in time domain. In addition, the contact signal between the slider and disk is measured by the electrical resistance method.

Development of Automatic Idle Stop Control System with Signals of ECU and TCU (ECU 및 TCU 신호를 이용한 자동차의 공회전 자동정지 제어 시스템 개발)

  • Kim Seong-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.7
    • /
    • pp.1601-1606
    • /
    • 2005
  • In this study, an automatic idle stop control system was developed, which automatically stops the idle state engine as it detects the stop state of the car for several seconds and restarts the stopped engine with the driver's electrical signal. It is composed of microprocessor and the related electronic circuits and communicates with ECU and TCU. With accurate and confirmed operating performance, the control system was equipped in the test car which was proceeded the ECE15+EUDC mode test. It is confirmed that the control system, ASG has much favourable effects on reducing the fuel consumption and harmful exhaust emissions.

Waterhammer in Transmission Pumping Station with Ball Valve (볼밸브를 사용한 송수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Kim, Joum-Bea
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1697-1702
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure. the hydraulic transients occur as a result of the sudden change in velocity. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations. in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

  • PDF

The Effect of the Variation of Pressure Ratio on the Characteristics of Lateral Forces in an Over-Expanded Nozzle (압력비 변화과정이 과팽창 노즐에서 발생하는 횡력 변동 특성에 미치는 영향)

  • Lee, Jong-Sung;Kim, Heuy-Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.6
    • /
    • pp.38-44
    • /
    • 2010
  • The shock wave and boundary layer interaction patterns in an over-expanded rocket nozzle are associated with the production of undesirable side-forces during the start-up and shut-down processes of the engine. In the present work, a computational study is carried out to investigate the effect of the transient nozzle pressure ratio (NPR) on the flow fields inside the nozzle. The unsteady, compressible, axisymmetric, Navier-Stocks equations with SST k-${\omega}$ turbulence model are solved using a fully implicit finite volume scheme. NPR is varied from 2.0 to 10.0, in order to simulate the start-up and shut-down processes of the rocket engine. It is observed that the interaction patterns and the hysteresis phenomenon strongly depend on the time variation of NPR, leading to significantly different characteristics in the lateral forces.

Durability Evaluation of Air-Cooled Proton Exchange Membrane Fuel Cells Stacks by Repeated Start-Up/Shut-Down (시동/정지반복에 의한 공랭식 고분자연료전지 스택 내구성 평가)

  • YOO, DONGGEUN;KIM, HYEONSUCK;OH, SOHYEONG;PARK, KWON-PIL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.315-323
    • /
    • 2021
  • The air-cooled proton exchange membrane fuel cells (PEMFC) stacks, which is widely used in small-sized PEMFC, have a problem in that durability is weaker than that of the water-cooled type. Because the cathode is open to the atmosphere and the structural problem of the air-cooled stack, which is difficult to maintain airtightness, is highly likely to form a hydrogen/air boundary during start-up/shut-down (SU/SD). Through the accelerated durability evaluation of the 20 W air-cooled PEMFC stack, the purpose of this study was to find out the cause of the degradation of the stack and to contribute to the improvement of the durability of the air-cooled PEMFC stack. In this study, it was possible to evaluate durability in a relatively short time by reducing 20-30% of initial performance by repeating SU/SD 1,000 to 1,200 times on an air-cooled PEMFC stack. After disassembling the stack, each cell was divided into two and the performance analysis showed that the electrode degradation was more severe in the anode outlet membrane electrode assembly (MEA), which facilitates air inflow as a whole, than in the inlet MEA. It was shown that the cathode Pt was dissolved/precipitated to deteriorate the polymer ionomer inside the membrane.

Effects of Storage Condition on Degradation of Automotive Polymer Electrolyte Membrane Fuel Cells (보관상태가 자동차용 고분자전해질 연료전지의 성능 감소에 미치는 영향)

  • Cho, Eun-Ae
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.4
    • /
    • pp.277-282
    • /
    • 2010
  • Durability of automotive polymer electrolyte membrane fuel cell (PEMFC) strongly depends the startup/shutdown procedure. Formation of hydrogen/air boundary in the anode gas channel, so-called reverse current condition, particularly induces fast degradation of the cathode. Under the reverse current condition, high voltage is present at the cathode facing air in the anode gas channel and is a function of residual oxygen concentration in the gas channels, that increases with storage time and reaches 21% (air) eventually. In this study, effects of residual oxygen concentration in a PEMFC on degradation of the PEMFC.