• Title/Summary/Keyword: 시간 분해 측정

Search Result 2,541, Processing Time 0.039 seconds

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

Development of Real-time Automatic Discharge Acquisition & Remote-control System (실시간 자동유량관측 시스템 개발)

  • Kim, Chang-Wan;Lee, Min-Ho;Cheong, Sang-Hwa;Kim, Ki-Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.551-555
    • /
    • 2007
  • 하구 감조부에서의 유량측정은 수문관측매뉴얼에 의하면 일반하천의 유량측정과 같은 원칙으로 실시하며, 일반 유량측정보다 신속하게 측정하고 유속과 유량을 연속적으로 측정해야 하고 조석을 잘 고려하여 관측계획을 수립하여야 하고 측정장비는 가급적 유향, 유속계의 기록부가 내장된 장비를 이용하도록 제안하고 있으며, 현실적으로 감조하천에서 유량측정은 많은 어려움이 따른다. 최근 우리나라에서 하천유량의 효율적인 측정을 위해 초음파유속계나 지표유속법과 같은 실시간 하천유량측정 방법이 도입되고 있다. 본 연구에서는 이러한 자동유량관측이 감조하천에 가능하도록 실시간 유량관측 시스템을 개발하여 운영하였다. 조석의 영향을 받는 한강대교지점에 도플러방식 초음파유량계를 회전체에 탑재한 자동유량측정장치를 남 북단 하천에 각각 1대씩 설치하였다. 본 시스템을 운영한 결과 무인 자동 연속 정밀관측이 가능하였으며, 1회 유속측정에 소요되는 $2{\sim}3$시간을 $5{\sim}6$분으로 단축시켰다. 이를 기반으로 감조하천에서의 자동유량관측이 가능하고 지표유속법을 도입하여 정확도를 높일 수 있는 유량산정기술을 개발하였다.

  • PDF

The Adhesion Property of Fish Glue (어교(魚膠)의 접착특성)

  • Lee, Young-Kyu;Hwang, Hyeon-Deuk;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.59-65
    • /
    • 2004
  • The present study aims to optimise the process parameters of fish glue and adhesion property through room temperature in terms of curing time and opened assembly time for attaining best adhesion strength to wood (Yellow birch, B. alleghaniensis). The uncured and cured fish glue have been characterised by TGA, DSC, FT-JR. It is observed that with increasing curing time up to 48 H, tensile lap shear strength of adhesive joint of fish glue to wood increases and decreases after 48 H. At 15 min. opened assembly time, lap shear strength increases up to 4833 kgf/cm2 and decreases after 15 min.

플라즈마 공정 진단을 위한 공간 분해 발광 분광 분석법 소개

  • Park, Chang-Hui;Kim, Dong-Hui;Choe, Seong-Won;Lee, Chang-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.81-81
    • /
    • 2013
  • 반도체, LCD, MEMs 등 미세 전자소자의 제작과 깊은 관련이 있는 IT 산업은 자동차 산업과 함께 세계 경제를 이끌고 있는 핵심 산업이며, 그 발전 가능성이 크다고 할 수 있다. 이 중 반도체, LCD 공정 기술에 관해서 대한민국은 세계를 선도하여 시장을 이끌어 나가고 있는 실정이다. 이들의 공정기술은 주로 높은 수율(yield)을 기반으로 한 대량 생산 기술에 초점이 맞추어져 있기 때문에, 현재와 같은 첨예한 가격 경쟁력이 요구되는 시대에서 공정 기술 개발을 통해 수율을 최대한으로 이끌어 내는 것이 현재 반도체를 비롯한 미세소자 산업이 직면하고 있는 하나의 중대한 과제라 할 수 있다. 특히 반도체공정에 있어 발전을 거듭하여 현재 20 nm 수준의 선폭을 갖는 소자들의 양산이 계획 있는데 이와 같은 나노미터급 선폭을 갖는 소자 양산과 관련된 CD (critical dimension)의 감소는 공차의 감소를 유발시키고 있으며, 패널의 양산에 있어서 생산 효율 증가를 위한 기판 크기의 대형화가 이루어지고 있다. 또한, 소자의 집적도를 높이기 위하여 높은 종횡비(aspect ratio)를 요구하는 공정이 일반화됨에 따라 단일 웨이퍼 내에서의 공정의 균일도(With in wafer uniformity, WIWU) 및 공정이 진행되는 시간에 따른 균일도(Wafer to wafer uniformity)의 변화 양상에 대한 파악을 통한 공정 진단에 대한 요구가 급증하고 있는 현실이다. 반도체 및 LCD 공정에 있어서 공정 균일도의 감시 및 향상을 위하여 박막, 증착, 식각의 주요 공정에 널리 사용되고 있는 플라즈마의 균일도(uniformity)를 파악하고 실시간으로 감시하는 것이 반드시 필요하며, 플라즈마의 균일도를 파악한다는 것은 플라즈마의 기판 상의 공간적 분포(radial direction)를 확인하여 보는 것을 의미한다. 현재까지 플라즈마의 공간적 분포를 진단하는 대표적인 방법으로는 랭뮤어 탐침(Langmuir Probe), 레이저 유도 형광법(Laser Induced Fluorescence, LIF) 그리고 광섬유를 이용한 발광분광법(Optical Emission Spectroscopy, OES)등이 있으나 랭뮤어 탐침은 플라즈마 본연의 상태에서 섭동(pertubation) 현상에 의한 교란, 이온에너지 측정의 한계로 인하여 공정의 실시간 감시에 적합하지 않으며, 레이저 유도 형광법은 측정 물질의 제한성 때문에 플라즈마 내부에 존재하는 다양한 종의 거동을 살필 수 없다는 단점 및 장치의 설치와 정렬(alignment)이 상대적으로 어려워 산업 현장에서 사용하기에 한계가 있다. 본 연구에서는 최소 50 cm에서 최대 400 cm까지 플라즈마 내 측정 거리에서 최대 20 mm 공간 분해가 가능한 광 수광 시스템 및 플라즈마 공정에서의 라디칼의 상태 변화를 분광학적 비접촉 방법으로 계측할 수 있는 발광 분광 분석기를 접목하여 플라즈마 챔버 내의 라디칼 공간 분포를 계측할 수 있는 진단 센서를 고안하고 이를 실 공정에 적용하여 보았다. 플라즈마 증착 및 식각 공정에서 형성된 박막의 두께 및 식각률과 공간 분해발광 분석법을 통하여 계측된 결과와의 매우 높은 상관관계를 확인하였다.

  • PDF

Development of Geometrical Quality Control Real-time Analysis Program using an Electronic Portal Imaging (전자포탈영상을 이용한 기하학적 정도관리 실시간 분석 프로그램의 개발)

  • Lee, Sang-Rok;Jung, Kyung-Yong;Jang, Min-Sun;Lee, Byung-Gu;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.77-84
    • /
    • 2012
  • Purpose: To develop a geometrical quality control real-time analysis program using an electronic portal imaging to replace film evaluation method. Materials and Methods: A geometrical quality control item was established with the Eclipse treatment planning system (Version 8.1, Varian, USA) after the Electronic Portal Imaging Device (EPID) took care of the problems occurring from the fixed substructure of the linear accelerator (CL-iX, Varian, USA). Electronic portal image (single exposure before plan) was created at the treatment room's 4DTC (Version 10.2, Varian, USA) and a beam was irradiated in accordance with each item. The gaining the entire electronic portal imaging at the Off-line review and was evaluated by a self-developed geometrical quality control real-time analysis program. As for evaluation methods, the intra-fraction error was analyzed by executing 5 times in a row under identical conditions and procedures on the same day, and in order to confirm the infer-fraction error, it was executed for 10 days under identical conditions of all procedures and was compared with the film evaluation method using an Iso-align$^{TM}$ quality control device. Measurement and analysis time was measured by sorting the time into from the device setup to data achievement and the time amount after the time until the completion of analysis and the convenience of the users and execution processes were compared. Results: The intra-fraction error values for each average 0.1, 0.2, 0.3, 0.2 mm at light-radiation field coincidence, collimator rotation axis, couch rotation axis and gantry rotation axis. By checking the infer-fraction error through 10 days of continuous quality control, the error values obtained were average 1.7, 1.4, 0.7, 1.1 mm for each item. Also, the measurement times were average 36 minutes, 15 minutes for the film evaluation method and electronic portal imaging system, and the analysis times were average 30 minutes, 22 minutes. Conclusion: When conducting a geometrical quality control using an electronic portal imaging, it was found that it is efficient as a quality control tool. It not only reduces costs through not using films, but also reduces the measurement and analysis time which enhances user convenience and can improve the execution process by leaving out film developing procedures etc. Also, images done with evaluation from the self-developed geometrical quality control real-time analysis program, data processing is capable which supports the storage of information.

  • PDF

Experimental Studies on Heat Conductivity of Human Bone and Torsional Strength of Pasteurized Porcine Tibia (생체골의 열전도성 및 열처리된 골의 염전력 변화에 대한 실험적 연구)

  • Park, Il-Hyung;Kim, Sin-Gun;Shin, Dong-Kyu;Ihn, Joo-Chul
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.1
    • /
    • pp.7-16
    • /
    • 1995
  • In countries where confucianism is popular, it is extremely hard to get fresh cadaver bone for allograft. Therefore in Korea, the reimplantation of resected autoclaved autogenous bone segments has been increasingly performed for limb reconstruction of extremities with malignancies. To preserve the bone morphogenetic protein and mechanical strength of heated bone, many studies have reported that pasteurization of bone is far better than autoclaving over $100^{\circ}C$. Based on this assumption, replacement with a pasteurized autogenous bone graft after resection of a malignant bone tumor was deemed feasible for reconstruction. However, little is known about how high a temperature and how much time for pasteurization is needed to make tumors completely necrotic and to maintain the mechanical strength of bone. Consequantly, experimental studies were carried out to test heat conductivity of human bone and torsional strength of porcine tibia after pasteurization. First, two pairs of human proximal tibia and distal femur were used. We used T-type thermocoples to check core temperature of the bone and a computerized data acquisition system to record results. Without reaming of the medullary cavity, in a $60^{\circ}C$-thermostatic saline tub, it took 32 minutes and 50 seconds to raise the core temperature of human proximal tibia from $20^{\circ}C$ to $58^{\circ}C$, and 30 minutes for distal femur. In a $80^{\circ}C$ saline tub, it took 12 minutes and 50 seconds for proximal tibia, and 11 minutes and 10 seconds for distal femur. In contrast, using porcine tibia whose cortical thickness is similar to that of human tibia, after reaming of the medullary canal, it took less than 3 minutes and 30 seconds in a $60^{\circ}C$ saline tub, less than 1 minute and 45 seconds in a $70^{\circ}C$ tub, and less than 1 minute in a $80^{\circ}C$ tub to elevate core temperature from $20^{\circ}C$ to $58^{\circ}C$. Second, based on data of the heat conductivity test, we compared the torsional strength before and after pasteurization. Twenty matched pairs of porcine tibia were used, The left one was used as a non-heated control group and the right one as a pasteurized experimental group. Wighout reaming of the medullary cavity, there was no statistical difference in torsional strength between the pasteurization of the $60^{\circ}C$-35minute and of $80^{\circ}C$-15minute. With reaming, we also found no statistical difference among pasteurization of $60^{\circ}C$-15 minute, of $70^{\circ}C$-15 minute, and of $80^{\circ}C$-15 minute groups. In conclusion, reaming of the medullary canal is very helpful in saving pasteurization time. And, in a $60^{\circ}C$ saline tub, no significant weakness in torsional strength occurs with pasteurization of the bone for up to 35 minutes. Also no significant weakness in torsional strength occurs with an exposure of 15 minutes to the $80^{\circ}C$ saline tub.

  • PDF

Development of Inverse Solver based on TSVD in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 TSVD 기반의 역문제 해법의 개발)

  • Kim, Bong Seok;Kim, Chang Il;Kim, Kyung Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.91-98
    • /
    • 2017
  • Electrical impedance tomography is a nondestructive imaging technique to reconstruct unknown conductivity distribution based on applied current data and measured voltage data through an array of electrodes attached on the periphery of a domain. In this paper, an inverse method based on truncated singular value decomposition is proposed to solve the inverse problem with the generalized Tikhonov regularization and to reconstruct the conductivity distribution. In order to reduce the inverse computational time, truncated singular value decomposition is applied to the inverse term after the generalized regularization matrix is taken out from the inverse matrix term. Numerical experiments and phantom experiments have been performed to verify the performance of the proposed method.

Catalytic Decomposition of Hydrogen Peroxide for Application on Micro Propulsion (마이크로 추력기 응용을 위한 과산화수소 촉매 분해 반응)

  • An Sung-Yong;Lee Jong-Kwang;Rang Seong-Min;Kwon Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.266-271
    • /
    • 2005
  • An experimental investigation of a microthruster using hydrogen peroxide as a monopropellant is described. The study comprises of preparation method of silver as a catalyst and performance evaluation of a catalytic reaction chamber. Silver was reduced in $H_2$ environment at $500^{\circ}C$. The catalytic reaction chamber was tested to determine the optimum configuration of the catalyst bed. The catalyst bed was made of a glass wafer substrate sputtered with silver and had a length of 20 mm. The conversion rate was measured with various residence time, catalyst bed temperature, catalytic coated area.

  • PDF

Isolation of Calcium-Binding Peptides from Barley Protein Hydrolysates (보리 단백질 가수분해물로부터 칼슘 결합 물질의 분리)

  • Lee, Ji-Hye;Choi, Dong-Won;Song, Kyung-Bin
    • Food Science and Preservation
    • /
    • v.19 no.3
    • /
    • pp.438-442
    • /
    • 2012
  • To prepare calcium-binding peptides as calcium supplement, barley proteins were hydrolyzed using Flavourzyme for 18 h and the hydrolysates were ultra-filtered under 3 kDa as a molecular weight. The resultant filtered peptides were fractionated using ion exchange and normal-phase high performance liquid chromatography. Then each fraction that was obtained was determined for its calcium-binding activity to isolate the calcium-binding peptides. As a result, the highest calcium-binding peptide fraction was obtained, and the results suggest that barley protein hydrolysates can be used as a calcium supplement.

Effects of Foliar Treatment of Underground Water, Chitosan Solution, and Wood Vinegar Solution on Residual Procymidone Removal in Altari Radish (지하수, 키토산 및 목초액의 엽면살포에 의한 알타리무 체내의 잔류 Procymidone 제거효과)

  • Jeong, Soon-Jae;Cho, Mi-Yong;Seok, Woon-Young;Oh, Ju-Sung
    • Korean Journal of Organic Agriculture
    • /
    • v.19 no.1
    • /
    • pp.121-134
    • /
    • 2011
  • For this study, Smilex powder, a pesticide, was sprayed on the Altari radish, and then underground water, Chitosan solution (${\times}$500), and wood vinegar solution (${\times}$1000) were evenly sprayed on the Altari radish respectively. Samples of Altari radishs for residual pesticide analysis were taken two hours, 1 day, 7 days, and 15 days after treatments, and the detectable concentration and degradability of procymidone, the pesticide residue, were measured. The results obtained are as follows: 1. When detectable concentration of procymidone within the altari radish was measured, treatment plots sprayed with underground water, Chitosan solution (${\times}$500), and wood vinegar solution (${\times}$1000) were found to show lower detectable concentration than the non-treatment plot which was sprayed with pesticide only. Especially, the treatment plots sprayed with Chitosan solution (${\times}$500), and with wood vinegar solution (${\times}$1,000) showed lower values than the average. 2. When the degradability of procymidone within the Altari radish was measured, the plot treated with Chitosan solution (${\times}$500) and the plot treated with wood vinegar solution (${\times}$1,000) were found to have relatively higher degradability of procymidone. There were not much differences among testing materials in the degradability of residual pesticides. However, the plot treated with Chitosan solution (${\times}$500) showed higher degradability. In terms of average degradability with time, degradability increased sharply 7 days after the foliar application of testing materials. 3. When the daily far-sighted view survey was conducted in order to find out growth disorder and damage on the Altari radish plants by the treatment of un-derground water, Chitosan solution (${\times}$500), and wood vinegar solution (${\times}$1,000), no symptomatic physiological disorders was observed on all the plants tested during the whole growing season at the tested concentration level.