• Title/Summary/Keyword: 시간 분해 측정

Search Result 2,541, Processing Time 0.031 seconds

Effective Porosity Variation of Cement Samples According to Vacuum Pressure and Time (진공의 압력과 시간을 달리할 때 시멘트시험편의 유효공극률 변화)

  • Lee, Sang Kyu;Lee, Tae Jong;Kim, Hyoung Chan
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.163-176
    • /
    • 2012
  • Effective porosity has been measured for cement specimen as a function of vacuum time and pressure in the vacuum saturation process. Six cement specimen are used; three of them are made of the same ratio of cement and sand, the other three are 100% cement mortar, of which average porosity is about 25% and 40%, respectively. Using the 6 samples, measured effective porosities are compared and examined with 5 different vacuum pressures (2, 4, 6, 8, 10 torr) and times (20, 40, 60, 80, 100 minute), respectively. Comparing measured effective porosity from experiments when vacuum time varies from 100 minute to 20 minute with 20 minute step and vacuum pressure is fixed to 10, 6, and 2 torr, average deviation decreases as 0.6, 0.5, and 0.2% respectively. Comparing measured effective porosity from experiments when vacuum pressure varies from 2 torr to 10 torr with 2 torr step and vacuum time is fixed to 100, 60, and 20 minute, average deviation increases as vacuum time decreases. These results can be a background of suggested method of ISRM that describes the vacuum time longer than 60 minute and vacuum pressure higher than 6 torr. In this study, only qualitative discussion can be possible for the effects on the effective porosity by decreasing 20 minute vacuuming time at the same pressure or by decreasing 2 torr of vacuum pressure at the same vacuum time. This is because the sample could not reached to perfectly dried condition even though the sample were dried at $105^{\circ}C$ and following the ISRM suggested method, so that initial water content could not be the same at each experiment.

전기화학증착 방법으로 성장시간에 따라 형성한 SnO2 나노세선의 구조적 성질

  • Lee, Chang-Hun;No, Yeong-Su;Lee, Dae-Uk;Kim, Tae-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.398-398
    • /
    • 2012
  • SnO2 나노세선은 n-형 전기적 성질과 화학적인 안정성 때문에 가스센서, 투명 전극 및 태양전지와 같은 전자소자와 광소자에 널리 사용되고 있다. 화학 기상 증착, 전자빔 증착과 전기화학증착법을 사용하여 SnO2 나노세선을 제작하고 있다. 여러 가지 증착 방법중에서 전기화학증착방법은 낮은 온도와 진공 공정이 필요하지 않으며 대면적 공정이 가능하고 빠른 성장 속도로 나노구조를 효과적으로 성장할 수 있는 장점을 가지고 있다. 본 연구에서는 전기화학증착법을 이용하여 Indium Tin Oxide (ITO) 기판 위에 SnO2 나노세선 성장하고 성장시간에 따라 형성한 SnO2 나노세선의 구조적 성질을 조사하였다. SnO2 나노세선을 성장하기 위하여 D.I. water와 Entanol을 7:3의 비율로 섞은 용액을 $65^{\circ}C$로 유지하였고, 0.015 M의 Tin chloride pentahydrate ($Cl4{\cdot}Sn{\cdot}5H2O$)를 타겟 물질로 이용하였고, 0.1 M의 Potassium chloride (KCl)를 완충 물질로 사용하였다. 전기화학증착 방법을 사용하여 제작한 ITO 기판위에 성장한 SnO2 나노세선 위에 전극을 제작하고 전류-전압 특성을 측정하였다. SnO2 나노세선이 성장되는 전기화학증착 전압을 1.2 V로 고정하고, 성장시간을 15분, 30분 및 1시간으로 변화하여 SnO2 나노세선의 구조적 특성을 분석하였다. X-선회절 (X-ray diffraction; XRD) 실험 결과는 $31^{\circ}$에서 (101) 성장방향을 갖는 SnO2 나노세선이 성장함을 확인하였고, 성장 시간이 길어짐에 따라(101) 성장방향의 XRD 피크의 intensity가 증가하였다. 전기화학증착 성장 시간이 길어짐에 따라 SnO2 나노세선의 지름이 60 nm에서 150 nm로 변화하는 것을 주사전자현미경으로 관측하였다. 이 실험 결과는 전기화학증착방법을 사용하여 제작한 SnO2 나노세선의 성장 시간에 따른 구조적 특성들을 최적화하여 소자제작에 응용하는데 도움이 된다.

  • PDF

Carbohydrate Repression of Dietary Induction of Ornithine ${\delta}$-Transaminase in Rat Liver (식이에 의한 Ornithine ${\delta}$-Transaminase의 유도(induction)와 억제(repression)에 관한 연구)

  • Parkpaik, Hyun-Suh
    • Journal of Nutrition and Health
    • /
    • v.12 no.3
    • /
    • pp.1-8
    • /
    • 1979
  • 단백질을 함유하지 않은 식이를 5일간 먹인 쥐에게 동량으로 혼합된 필수 아미노산 혼합물(amino acid mixture)을 투여 하여 ornithine $\delta$-transamiaase(OT)를 유도(induction)한 군과 또한 amino acid mixture를 먹인 후 $6{\sim}9 \;1/2$시간 후에 glucose를 동시에 먹인 군에서 OT의 유도 기전을 보기 위하여 방사성 동위원소인 L-methionine-$CH_{3}-C^{14}$ 또는 L-Phenylalanine-$H^{3}$(uniformly labelled) 을 사용하여 유도전 OT를 pulse label하여 준비된 항체로 각각 유리 분리시켜서 방사능을 측정하였다. Amino acid mixture만을 투여한 군에서는zero time에 비해 OT활성은 6시간 후에 1.5배, 12시간 후에는 약 3배, 18시간 후에는 13배가 증가되었다. 또한 OT에 incorporate된 표지 아미노산의 방사능은 6시간 후에 1.5배, 12시간 후에 약 3배가 증가 되었을을 보였다. 그러나 이 기간동안 간장의 total soluble protein에 incorporate된 표지 아미노산의 방사능은 거의 증가하지 않았다. 그러므로, amino acid mixture에 의한 OT의 증가는 고유하게 유도되었으며 이때의 관성의 증가는 OT 단백질의 분해률의 감소에 의한 것이 아니라 순수하게 OT 단백질의 생합성에 의찬 증거라고 볼 수 있다. amino acid mixture를 투여한지 6시간 후에 glucose 용액을 동시에 먹인 쥐에서는 OT 활성은 증가를 하였으나 amino acid mixture만을 먹인 군보다는 약간 감소를 보였다. 또한 glucosedp이 투여된 후에는 OT에 표지 아미노산이 더 이상 incorporate되지는 않아 방사능의 증가는 보이지 않았으나 glucose가 투석될 당시보다 더 이상 감소되지는 않았다. 그러므로 glucose에 의한 유도에 대한 억제 (repression)는 단백질의 분해률의 증가에서 온 것이라기 보다는 OT 단백질의 생합성을 억제하여서 $OT_{1}$활성을 감소하지 않았는가 본다.

  • PDF

Kinetics and Equilibrium Study on β-glucosidase under High Hydrostatic Pressure (고압에서 β-glucosidase 반응속도론 및 평형에 관한 연구)

  • Han, Jin Young;Lee, Seung Ju
    • Food Engineering Progress
    • /
    • v.15 no.3
    • /
    • pp.214-220
    • /
    • 2011
  • $\beta$-Glucosidase enzyme reaction under high hydrostatic pressure was investigated in terms of physical chemistry. A model substrate (p-nitrophenyl-${\beta}$-D-glucopyranoside(pNPG)) was used, and the pressure effects on the enzymatic hydrolysis (pNPG${\rightarrow}$pNP) at 25 MPa, 50 MPa, 75 MPa, and 100 MPa were analyzed. Two parts of the reaction such as kinetic and equilibrium stages were considered for mathematical modelling, and their physicochemical parameters such as forward and inverse reaction constants, equilibrium constant, volume change by pressure, etc. were mathematically modeled. The product concentration increased with pressure, and the two stages of reaction were observed. Prediction models were derived to numerically compute the product concentrations according to reaction time over kinetic to equilibrium stages under high pressure condition. Conclusively, the $\beta$-Glucosidase enzyme reaction could be activated by pressurization within 100 MPa, and the developed models were very successful in their prediction.

Chemical Oxygen Demand based on Spectrophotometric Measurement of Permanganate (흡광도 측정에 의한 화학적 산소 요구량)

  • Myung-Zoon Czae;Suw-Young Ly;Mi-Kyung Kim
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.12
    • /
    • pp.880-884
    • /
    • 1994
  • An indirect spectrophotometric method, presumably heretofore unmentioned, for the rapid determination of COD in the presence of chloride of high concentration is described. The alkaline sample is refluxed to react with a definite amount of permanganate, present in excess. A photometric measurement at 535 nm for the extent of the fading of the permanganate color after refluxing completes the procedure. The optimum conditions which give the absorbance-concentration plot the maximum linearity and slope in the range of 0∼5 ppm COD are as follows: reflux at $100\circC$ for 10 min in the presence of 0.15 mM permanganate and 0.2% NaOH with a sample size of 5 ml. An overall running time was less than 15 min. The t-test reveals that the proposed method is not significantly different from the official method.

  • PDF

Effects of Alkali-protease Treatments on Acidity, Viscosity and Color of Anchovy Extracts (알칼리 및 효소처리가 멸치추출액의 산도, 점도 및 색에 미치는 영향)

  • Park, Joo-Young;Kim, Hye-Kyung;Kim, Woo-Jung;Yun, Shuk-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.488-492
    • /
    • 1988
  • The physicochemical properties of viscosity, color, acidity and volume of anchovy extract were measured for their changes during extraction with alkali solution and/or proteolytic enzymes. The dried anchovies were ground in 0.3N NaOH solution followed by hydrolysis with neutral or alkaline protease and centrifuged to obtain anchovy extract. The results showed that the volume of supernatant after centrifugation increased from 70% of water only extraction to 89% by combined alkali-enzyme treatment. Titratable acidity of the extract showed a tendency of a little increase while viscosiy decreased with prolonged enzymic hydrolysis. Changes in Hunter value of 'L', 'a', 'b' showed that the extract became darker and less yellowish as protease treatment prolonged.

  • PDF

The Influence of Assay Error on Amikacin Pharmacokinetics the Nonlinear Least Square Regression and Bayesian Analysis in Gastric Cancer Patients (위암환자에서 비선형최소자승 회귀분석과 베이시안 분석에 의한 아미카신의 약물동태에 분척오차의 영향)

  • Choi, Jun-Shik;Burm, Jin-Pil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.18 no.1
    • /
    • pp.11-17
    • /
    • 2008
  • 아미카신은 그람음성균 감염에 사용하는 아미노글리코사이드계 항생제로 이독성 및 신독성 등의 부작용과 큰 개인차로 혈중농도 모니터를 통한 투여계획이 필요한 약물이다. 본 연구에서는 16명의 위암환자에서 비선형최소자승 회귀분석과 베이시안 분석에 의한 아미카신의 약물동태에 분석오차의 영향을 연구하였다. 약물투여는 아미카신 7.5 mg/kg을 30분에 걸쳐 12시간 간격으로 등속 주입하였으며, 혈액 채취는 정상상태에 도달되었다고 판단되는 첫 약물투여 72시간 후에, 약물 주입 5분전과 주입이 끝난 뒤 30분과 2시간에서 세차례 채취하였다. 혈청중 약물농도는 형광편광면역법으로 측정하였다. 분석오차를 위해 0, 5, 15, 30, 60 및 $80\;{\mu}g/ml$에 해당하는 아미카신 혈중농도(C)을 네차례 측정하여 각 혈중농도의 표준편차 (SD)을 구하였다 아미카신 분석오차를 위한 다항식이 $SD=0.3017+(0.00538C)+(0.00112C^2)$, $R^2=0.974$이었다 이 식에서 구한 SD 값으로 분석시 가중치를 주었을 때, 비선형최소자승 회귀분석에 의한 아미카신의 약물동태학적 파라메타($V_d$, $K_{el}$, $K_{slpoe}$, $t_{1/2}$)에 유의성있는 영향을 주었으나, 베이시안 분석에 의한 아미카신의 약물동태학적 파라메타에는 영향이 없었다. 이 다항식에 의한 분석오차를 비선형최소자승 회귀분석에 의한 아미카신 약물동태학적 파라메타 분석시 적절히 사용하면 안전하고 효율적인 투여계획을 할 수 있다.

  • PDF

The Influence of Assay Error on Tobramycin Pharmacokinetics using the Nonlinear Least Square Regression and Bayesian Analysis in Gastric Cancer Patients (위암환자에서 비선형 최소자승 회귀분석과 베이시안 분석에 의한 토브라마이신의 약물동태에 분석오차의 영향)

  • Choi, Jun-Shik;Burm, Jin-Pil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • 토브라마이신은 그람음성균 감염에 사용하는 아미노글리코사이드계 항생제로 이독성 및 신독성 등의 부작용과 큰 개인차로 혈중농도 모니터를 통한 투여계획이 필요한 약물이다. 본 연구에서는 16명의 위암환자에서 비선형 최소자승 회귀분석과 베이시안 분석에 의한 토브라마이신의 약물동태에 분석오차의 영향에 대하여 연구하였다. 약물투여는 토브라마이신 1-2 mg/kg을 30분에 걸쳐 8시간 간격으로 등속 주입하였으며, 혈액 채취는 정상상태에 도달되었다고 판단되는 첫 약물투여 72시간 후에, 약물 주입 5분전과 주입이 끝난 뒤 30분과 2시간에서 세차례 채취하였다. 혈청중 약물농도는 형광편광면역법으로 측정 하였다. 분석오차를 위해 0, 1, 2, 4, 8 및 12 ${\mu}g/mL$에 해당하는 토브라마이신 혈중농도(C)을 네차례 측정하여 각 혈중농도의 표준편차 (SD)을 구하였다. 토브라마이신 분석오차를 구하기 위한 다항식이 SD = 0.0224+0.0540C+0.00173C2, $R^2$ = 0.935이었다. 이 식에서 구한 SD 값으로 분석시 가중치를 주었을 때, 비선형 최소자승 회귀분석에 의한 토브라마이신의 약물동태학적 파라메타 ($V_d$, $K_{el}$, $K_{slpoe}$, $t_{1/2}$)에 유의성있는 영향을 주었으나, 베이시안 분석에 의한 토브라마이신의 약물동태학적 파라메타에는 영향이 없었다. 이 다항식으로 부터 구한 분석오차를 토브라마이신의 비선형 최소자승 회귀분석을 이용한 약물동태 연구 및 파라메타 분석에 적용하여 좀 더 정확한 투여용량을 결정할 수 있으며, 더 나아가 토브라마이신 약물동태 시뮬레이션 연구에 응용할 수 있다.

  • PDF

Precessional Motion of Ferromagnetic Pt/Co/Pt Thin Film with Perpendicular Magnetic Anisotropy (수직 자기 이방성을 갖는 Pt/Co/Pt 자성 박막의 세차 운동 측정 및 분석)

  • Yun, Sang-Jun;Lee, Jae-Chul;Choe, Sug-Bong;Shin, Kyoung-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.6
    • /
    • pp.204-207
    • /
    • 2011
  • We developed a time-resolved magneto-optical Kerr effect microscope system to investigate ultrafast magnetization dynamics. Based on the pump-probe method, 0.1-ps time resolution was achieved by use of a fs Ti:Sapphire laser. The magnetization dynamics was then measured on Pt/Co/Pt thin films with various Co thicknesses. All the samples exhibited ultrafast demagnetization within a few ps by direct heating of pump laser. Some thicker samples showed precessional motion of magnetization, from which the Gilbert damping constant was determined based on the Landau-Lifshitz-Gilbert equation.

Development of Assembly for Fast BOD Estimation and Its Applications (신속한 BOD 측정장치의 개발과 응용)

  • Soon, Moo-Jeong;Kim, Eun-Jeong;Jang, Seh-Yong;Hong, Daeil
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.285-291
    • /
    • 1994
  • A microbial BOD sensor for the continuous estimation of BOD was been developed by immobilizing Trichosporon cutaneum, which was immobilized between a dialysis and a gas-permeable membrane, on an oxygen electrode. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $32{\sim}33^{\circ}C$, respectively. The best result was obtained at 2~3ml/min flow rate in 0.1M phosphate buffer solution. A linear relationship was observed between ${\Delta}DO$ and the concentration of standard GGA solution below 60mg/l(90ppm $BOD_5$). The reproducibility was found to be within 3% for the standard solution containing glucose 30mg/l and glutamic acid 30mg/l. The output DO value of this sensor was almost constant for 30 dalys. The response time and the recovery time were about 5 and 10 min, respectively. This sensor was employed for the BOD measurement of waste pollutants and was compared with $BOD_5$ method.

  • PDF