• Title/Summary/Keyword: 시간슬롯

Search Result 284, Processing Time 0.026 seconds

Design and Performance Analysis of a new MAC Protocol for Providing Real-time Traffic Information using USN (USN 기반 실시간 주행 상황 정보 제공을 위한 MAC 설계 및 성능 분석)

  • Park, Man-Kyu;So, Sang-Ho;Lee, Jae-Yong;Lim, Jae-Han;Son, Myung-Hee;Kim, Byung-Chul
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.5
    • /
    • pp.38-48
    • /
    • 2007
  • In ubiquitous environment, sensor networks that sense and transmit surrounding data without human intervention will become more important. If sensors are installed for detecting vehicles and measuring their speed in the road and that real-time information is given to drivers, it will be very effective for enhancing safety and controlling traffic in the road. In this paper, we proposed a new reliable and real-time sensor MAC protocol between AP and sensor nodes in order to provide real-time traffic flow information based on ubiquitous sensor networks. The proposed MAC allocates one TDMA slot for each sensor node on the IEEE 802.15.4 based channel structure, introduces relayed communication for distant sensors, and adopts a frame structure that supports retransmission for the case of errors. In addition, the proposed MAC synchronizes with AP by using beacon and adopts a hybrid tracking mode that supports economic power consumption according to various traffic situations, We implemented a simulator for the proposed MAC by using sim++ and evaluated various performances. The simulation results show that the proposed MAC reduces the power consumption and reveals excellent performance in real-time application systems.

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE (결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향)

  • Shin, Hyun-Jeong;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.813-823
    • /
    • 1998
  • The frictional force has been considered as an harmful factor in an active unit where tooth movement occurs, but as an advantageous factor in anchor unit that resist tooth movement. That is, efficient tooth movement is planned by using ligation methods that have low levels of bracket-wire frictional force and the anchorage control can be achieved by using ligation methods that have high levels of bracket-wire frictional force that result in binding of the bracket accompanied by little or no tooth movement. The purpose of this study was to evaluate the frictional force generated between bracket and wire in accordance with the methods of ligation, the material of ligation and the passage of time under artificial saliva. Tested were 0.017x0.022 inch stainless steel wires in standard edgewise twin brackets for upper central incisors in a 0.018-inch slot. The wires were ligated into the brackets with elastomeric modules and stainless steel ligatures. Whole tie, half tie, twisting tie and double overlay tie were done with elastomeric modules. With 0.009-inch stainless steel ligature whole tie and half tie were done by needle holder and whole tie by ligature tying plier. With 0.012-inch stainless steel ligature whole ties were done by needle holder. Whole tie groups of elastomeric module were kept in artificial saliva bath at $37^{\circ}C$ for 28 days. The frictional force was recorded by means of an Instron universial testing instrument (4202 INSTRON, Instron Co., U.S.A.) at initial, 7, 14, 21, and 28 days. The results for ligated samples in a simulated oral environment revealed the fellowing : ${\cdot}$In elastomeric module whole tie, 28 days group was significantly greater mean static frictional force than any other group but there were no significant differences among any other group (p>0.05). ${\cdot}$Elastomeric module twisting ties were significantly greater mean static frictional forces than any other ligation method but there were no significant differences between twisting tie and double overlay tie (p>0.05). Twisting tie, double overlay tie, whole tie, half tie showed differences in decreasing order. ${\cdot}$Stainless steel half tie produced lower mean static frictional force than whole tie, ligation by ligature tying plier produced greater mean static frictional force than by needle holder and ligation with 0.012-inch stainless steel ligature produced greater mean static frictional force than with 0.009-inch stainless steel ligature (p<0.05). ${\cdot}$There were no significant differences between the mean static frictional forces of elastomeric whole tie and stainless steel whole tie (p>0.05).

  • PDF

Improvement of the Fishing Gear and Fishing Method of the East-Sea Trawl Fishery (동해구 트롤 어구어법의 개량)

  • 권병국;이주희;이춘우;김형석;김용식;안영일;김정문
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.106-116
    • /
    • 2001
  • A serious of studies on the fishing gear and system of the East Sea trawl fishery was carried out to improve the fishing efficiency and the working conditions. As the first step of these studies, the fishing gear and system of the traditional East Sea trawl were checked in order to solve the some problems, such as the poor sheering efficiency of net mouth, the inconvenient fishing system of the side trawl and etc. And then the fishing system was reorganized from the side trawl into the stern trawl by setting up the net drum system on the stern deck, and introduction of two types of new designed nets, one for mainly the midwater trawl and the other for the bottom trawl. The results of the field experiment on the modified system and nets can be summarized as follows : 1. the modified system was well worked and could save the man-labour by about 80%. 2. The sheering efficiency of the improved net, A type was improved to 20 m height and 30 m width in the net mouth, and that of B type net, to 10 m height and 33 m width, compared with 1.5 m height and 15 m width in the traditional net. 3. Catch efficiency of pink shrimp in A or B type net was better about 3 or 5 times than that of traditional net, and in B net, for herring and other bottom fishes is better about 2 times than that of the traditional net.

  • PDF