THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE

결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향

  • Shin, Hyun-Jeong (Department of Orthodontics, School of Dentistry, Kyungpook National University) ;
  • Kwon, Oh-Won (Department of Orthodontics, School of Dentistry, Kyungpook National University) ;
  • Kim, Kyo-Han (Department of Dental Materials, School of Dentistry, Kyungpook National University)
  • 신현정 (경북대학교 치과대학 교정학교실) ;
  • 권오원 (경북대학교 치과대학 교정학교실) ;
  • 김교한 (경북대학교 치과대학 치과재료학 교실)
  • Published : 1998.10.01

Abstract

The frictional force has been considered as an harmful factor in an active unit where tooth movement occurs, but as an advantageous factor in anchor unit that resist tooth movement. That is, efficient tooth movement is planned by using ligation methods that have low levels of bracket-wire frictional force and the anchorage control can be achieved by using ligation methods that have high levels of bracket-wire frictional force that result in binding of the bracket accompanied by little or no tooth movement. The purpose of this study was to evaluate the frictional force generated between bracket and wire in accordance with the methods of ligation, the material of ligation and the passage of time under artificial saliva. Tested were 0.017x0.022 inch stainless steel wires in standard edgewise twin brackets for upper central incisors in a 0.018-inch slot. The wires were ligated into the brackets with elastomeric modules and stainless steel ligatures. Whole tie, half tie, twisting tie and double overlay tie were done with elastomeric modules. With 0.009-inch stainless steel ligature whole tie and half tie were done by needle holder and whole tie by ligature tying plier. With 0.012-inch stainless steel ligature whole ties were done by needle holder. Whole tie groups of elastomeric module were kept in artificial saliva bath at $37^{\circ}C$ for 28 days. The frictional force was recorded by means of an Instron universial testing instrument (4202 INSTRON, Instron Co., U.S.A.) at initial, 7, 14, 21, and 28 days. The results for ligated samples in a simulated oral environment revealed the fellowing : ${\cdot}$In elastomeric module whole tie, 28 days group was significantly greater mean static frictional force than any other group but there were no significant differences among any other group (p>0.05). ${\cdot}$Elastomeric module twisting ties were significantly greater mean static frictional forces than any other ligation method but there were no significant differences between twisting tie and double overlay tie (p>0.05). Twisting tie, double overlay tie, whole tie, half tie showed differences in decreasing order. ${\cdot}$Stainless steel half tie produced lower mean static frictional force than whole tie, ligation by ligature tying plier produced greater mean static frictional force than by needle holder and ligation with 0.012-inch stainless steel ligature produced greater mean static frictional force than with 0.009-inch stainless steel ligature (p<0.05). ${\cdot}$There were no significant differences between the mean static frictional forces of elastomeric whole tie and stainless steel whole tie (p>0.05).

마찰력은 치아이동시 활주이동부에 유해한 인자로 인식되어져 왔으나 치아이동에 저항하는 고정원에 있어서는 유리한 인자로 받아들여질 수 있다. 즉 마찰력이 작은 결찰법들을 이용하여 효과적인 치아이동을 도모하는 반면 마찰력이 큰 결찰법들을 이용하여 브라켓의 걸림에 의해 치아이동이 거의 일어나지 않게 하면 고정원을 강화할 수 있다. 인공타액하에서 시간경과에 따른 교정선과 브라켓 사이의 마찰력 변화, 탄성 모듈과 스테인레스 강 결찰선을 이용하여 각각 결찰양식을 달리 하였을 때의 마찰력 변화 그리고 결찰재의 재료를 달리 하였을 때의 마찰력 변화를 알아보기 위하여 .018"x.025" 슬롯의 상악 중절치용 standard edgewise twin 브라켓과 .017"x.022" 스테인레스 강 교정선을 탄성 모듈, .009" 스테인레스 강 결찰선 그리고 .012" 스테인레스 강 결찰선을 이용하여 다양하게 결찰하였다. 또한 통상적인 방법으로 결찰한 탄성 모듈 결찰군을 결찰 직후와 1주 간격으로 4주간 마찰력을 측정하여 다음과 같은 결과를 얻었다. ${\cdot}$탄성 모듈 whole tie시 시간경과에 따른 마찰력은 4주 경과시 가장 높았으나 3주, 2주, 1주, 결찰 직후간에는 통계학적으로 유의한 차이가 없었다 (p>0.n). ${\cdot}$탄성 모듈로 결찰시 마찰력은 twisting tie가 가장 높았고 double overlay tie, whole tie, half tie 순으로 나타났으나 twisting tie와 double overlay tie 간에는 통계학적으로 유의한 차이가 없었다 (p>0.05). ${\cdot}$스테인레스 강 결찰선으로 결찰시 half tie 군이 whole tie 군보다 낮은 마찰력을 보였으며 ligature tying plier로 결찰한 경우가 needle holder로 결찰한 경우보다 더 높았고 .012" 결찰선을 이용한 경우가 .009" 결찰선을 이용한 경우보다 더 높았다 (p<0.05). ${\cdot}$통상적인 방법으로 탄성 모듈과 스테인레스 강 결찰선을 이용하여 결찰한 경우 두 군간에 유의한 차이가 없었다(p>0.05).

Keywords