• Title/Summary/Keyword: 시간변동율

Search Result 225, Processing Time 0.028 seconds

A Case Study on Phytoremediation in Polluted Stream by Heilianthus annuus (Heilianthus annuus에 의한 오염된 하천에서의 Phytoremediation에 관한 연구)

  • Choi, Moon-Sul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.11 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • This is the research to prepare a purification program for relatively less polluted stream by using phytoremediation. We calculated a treatment amount of nutrients followed by growth of Helianthus annuus (a kind of sunflower), setting up the plant reactor in the hothouse. Moreover, to investigate a field applicability, we could find increased contents of nitrogen, carbon and hydrogen in plants by setting up a H. annuus planted artificial floating island in an irrigation canal. When we changed the dissolved inorganic nitrogen(DIN) concentration of the influent from 28.5 to 199.2 mg/l and the dissolved inorganic phosphorus(DIP) concentration of the influent from 13.3 to 25.4 mg/l, growth disorder has not appeared though it is much higher than the criterion of water for irrigation. In this case, the removal rate of DIN was $81.7\sim98.6%$, and that of DIP was $81.9\sim98.4%$ in 3 days stay on average. It has appeared that the efficient hydraulic retention time(HRT) was 48 hours. The following contents of nitrogen, carbon and hydrogen of H. annuus appeared in the artificial floating island: nitrogen was $3.2\sim7.8%$ in the trunk and $3.0\sim6.3%$ in the root. Carbon was $40.1\sim57.7%$ in the trunk and $43.4\sim53.8%$ in the root.

An Epidemiological Study on the Industrial Injuries among Metal Products Manufacturing Workers in Young-Dung-Po, Seoul (일부 금속 및 기계제품 제조업체 근로자들의 산업재해($1980{\sim}1981$)에 관한 조사)

  • Lee, Jung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.15 no.1
    • /
    • pp.187-196
    • /
    • 1982
  • The followings are the results of the study on industrial accidents occurred at 12 factories manufacturing metal products during the period of 2 years from January 1980 to December 1981 in the area of Yong-Dung-Po in Seoul. The results of the study are as follows: 1. The incidence rate of industrial injuries was 45.7 per 1,000 workers of the sample group and the rate of male (54.0) was three times higher than that of female (17.5). 2. In age groups, the highest rate was observed in the group of under 19 years old with 83.5, while the lowest in the group of 40s. 3. It was found that those who had short term of work experience produced a higher rate of injuries, particularly, the group of workers with less than 1 year of experience showed the highest rate of it as 48.1%. 4. In working time, the highest incidence rate occurred 3 and 7 hours after the beginning of their working showing the rate of 6.0 and 6.1 per 1,000 workers, respectively. 5. The highest incidence rate was observed on Monday as 8.4 per 1,000 workers, and it was 18.3% in aspect of the days of a week. 6. In aspect of the months of a year, the highest incidence was observed on July 1,000 workers and the next was on March as 4.8. These figures account for 11.8% of total occurrence in respective month. as 5. 4 per and 10.5% 7. In causes of injuries, the accident caused by power driven machinery showed the highest rate with 37.5%, the second was due to handling without machinery with 17.2%, and the third was due to falling objects with 14.2%, and striking against objects with 10.2%, and so on. 8. By parts of the body affected, the most injuries 84.3% of them occurred on both upper and lower extremities with the rate of 58.8% for the former and 25.5% for the latter. Fingers were most frequently injured with a rate of 40.3%. Comparing the sites of extremities affected, rate of injuries on the right side was 55.0% and 45.0% on the left side. 9. In the nature of injury, laceration and open wound were the highest with 34. 0%, the next was fracture and dislocation with 31. 9%, and sprain was the third with 8.1%. 10. On the duration of treatment, it lasted less than one month in 68.9% of the injured cases, of which 14.5% of the cases were recovered within 2 weeks, and 54.4% of them were treated more than 2 weeks. And the duration of the treatment tended to be prolonged in larger industries. 11. The ratio of insured accidents to uninsured accidents was 1 to 4.7.

  • PDF

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.

Research on Changing of Renal Relative Uptake Depending on the Setting of Background ROI in Kidney MAG3 Study of Hydronephrosis Patients (Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구)

  • Noh, Ik Sang;Ahn, Byung Ho;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • Purpose: To evaluate kidney function, renal relative uptake is very important and is affected by kidney and the setting of background region of interest (ROI). In particular, in the case of patients with hydronephrosis to the naked eyes, such as size, position and shape etc. can be difficult to identify. So according to ROI to be set by user, the results are many differences. This study assumes the ROI of a constant kidney. According to the change of background ROI by analyzing renal relative uptake affect how the results are intended to study. Materials and Methods: From January 2012 to February 2013, we analyzed 27 patients with hydronephrosis who were examined MAG3 test in nuclear medicine department of Samsung medical center. After patients were received intravenous injection of $^{99m}Tc-MAG3$ 185 MBq (5 mCi) data were obtained. While we reconstructed images of patients, we've changed background ROI in the process of setting up ROI. First, in the process of renal processing, automatic ROI which set automatically and background ROI which needed to set manually were compared. Second, we set the ROI position separated by above, lateral and bottom of kidney. Third, background setting time were compared with 1-2 min and 2-3 min. Results: The relative uptake occurred in 3.7%p of the errors on average in Automatic & Manual ROI study. And comparison of background ROI position study, located in the lower position was more accurate results. Above, lateral, bottom each of the values 74.6%, 67.6% and 62.0% showed respectively. The standard value was 59.9%. finally, split function range test doesn't show significant difference. Conclusion: The study shows that relative uptake of kidney is affected in the background ROI. Therefore, it should be set by considering various dependent factors.

  • PDF

Analysis of long-term water level change of Dongrae hot spring using time series methods (시계열 방법을 이용한 동래온천 수위의 장기적인 변화 분석)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Cheong, Jae-Yeol;Lee, Cheol-Woo;Lee, Jong-Tae;Lim, Woo-Ri
    • Journal of the Geological Society of Korea
    • /
    • v.54 no.5
    • /
    • pp.529-544
    • /
    • 2018
  • Dongrae hot spring belongs to the residual magma type and has a long history of bathing since the Silla dynasty in Korea. Due to long development of hot spring water, it is expected that the amount of hot spring water in Dongrae hot spring has been changed. In this study, long-trem water level data of Dongrae hot spring were examined for recognizing the change of the hot spring. By the fluctuation analysis of the hot spring water level from January 1992 to July 2018, the maximum and minimum annual drawdowns of no. 27 well were 137.70 and 71.60 meters, respectively, with an average drawdown of 103.39 m. On the other hand, the maximum and minimum annual drawdowns of no. 29 well were 137.80 and 71.70 meters, with an average drawdown of 103.49 m. Besides, drawdown rate became bigger in recent years. As a result of analyzing autocorrelation of the two wells, the correlation coefficient ranged from 0.919 to 0.991, showing seasonal groundwater level fluctuation. The cross correlation analysis between water level and precipitation as well as water level and hot spring discharge resulted in the correlation coefficients of -0.280 ~ 0.256 and 0.428 ~ 0.553, respectively. Therefore, using Dongnae hot-spring water level data from 1992 to 2018, the Mann-Kendall test and Sen's test showed that the continuous decline of water level was mainly caused by the pumping of the hot spring water among various reasons.

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF

Photosynthesis and Chlorophyll Fluorescence of Evergreen Hardwoods by Drying Stress (건조 스트레스가 난대 상록활엽수의 광합성 반응 및 엽록소 형광반응에 미치는 영향)

  • Jin, Eon-Ju;Yoon, Jun-Hyuk;Bae, Eun-Ji;Choi, Myung-Seok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.3
    • /
    • pp.196-207
    • /
    • 2019
  • This study was carried out to investigate the effects of C. japonica, D. morbifera, D. macropodum, I. anisatum, Q. glauca and R. indica To investigate the photosynthetic ability, chlorophyll content, chlorophyll fluorescence analysis, and physiological environmental. The photosynthetic rate, cancer respiration rate, stomatal conductance, and rate of evaporation tended to decrease as a result of drying stress in the no-water condition for 28 days. I. anisatum, Q. glauca and R. indica showed a low rate of less than 40% until 28 days of no-treatment. The total chlorophyll contents were decreased in the order of D. macropodum> D. morbifera> C. japonica> Q. glauca> M. thunbergii> R. indica> I. anisatum. Chlorophyll fluorescence analysis showed that there was no change in the qP, but after 28 days no $Fv/F_m$, $F_o$, $R_{fd}$, $NPQ_{_-LSS}$ can be a useful indicator for quantitative estimation within a short period of time with a marked reduction rate of PSII quantum yield ${\Phi}PSII$ in the rectified state by continuous light during the nominal adaptation period. In the case of I. anisatum, Q. glauca and R. indica If water management can be carried out at intervals, it may be possible to plant trees in trees and landscape trees.

Numerical Simulation on Control of Tsunami by Resonator (II) (for Samcheok port) (공진장치에 의한 지진해일파의 제어에 관한 수치시뮬레이션(II) (삼척항에 대해))

  • Lee, Kwang-Ho;Jeon, Jong-Hyeok;Kim, Do-Sam;Lee, Yun-Du
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.496-505
    • /
    • 2020
  • In the previous research, the effectiveness of resonator was confirmed through the numerical analysis on two cases with the use of existing resonator at the Mukho and Imwon ports located in the eastern coast of South Korea by discussing the reduction rates of 1983 Central East Sea tsunami, and 1993 Hokkaido Southwest off tsunami, respectively. In this study, the reduction rates of tsunami height with three different resonators, Type I, II-1, and II-2, at the Samcheok port were examined respectively through the numerical analysis using COMCOT model under the same condition as the previous study. It was discussed the spatial distribution of maximum height of tsunami, change of water level, and effectiveness of resonator with the presence of new types of resonator, and change of their sizes. As a result, the effectiveness of resonator was verified through the application of new types of resonator reducing about maximum 40% of tsunami height. In order to design the optimal resonator for the variety of site condition, it is necessary to research about the various cases applying different shape, arrangement, and size of resonator as further study.

Histopathological and Serological Observations on Experimental Anisakiasis of Rabbits (실험적 토끼 아니사키스증에서의 조직학적 병변과 혈청 항체가의 경시적 변동 양상)

  • 홍성태;이손형
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.2
    • /
    • pp.168-180
    • /
    • 1987
  • This study was performed to observe histopathological changes and serological reactions in chronic anisakiasis of rabbits. Each rabbit was infected per os with 30 larvae of Anisakis type I. Their sera were collected chronologically and the rabbits were killed for histopathological examination, 3, 13, 20, 30, 60, 90 and 150 days after the infection. The results were summarized as below. 1. Most of the larvae were recovered from the stomach, but a few from the omentum, intestine, mesentery and abdominal wall. The recovery rates and distribution of worms by organ were not differed by duration of infection. 2. Histologically the lesion was abscess type on 13 days, i.e., the dead worms were surrounded by fibrinous exudate, histiocytes and thick zone of numerous inflammatory cells. After 30 days, histiocytes were found to invade the worms and the lesion was changing into abscessgranulomatous type. Also a calcified worm was found on the 30th day. After then the worms were observed to be dissolved slowly until 90 days. On 150 day, only one calcified worm was observed. 3. The levels of serum IgG antibody by ELISA reached their maximum 30 days after the infection. After then, it decreased slowly until 150 days after the infection. Above serological and histopathological findings indicated that antigenic stimulation from degenerating Anisakis larvae was the greatest during the first 30 days after infection. This period was corresponding with the beginning of worm resolution or calcification. Serologic test by ELISA would be a valuable tool for confirming chronic anisakiasis.

  • PDF

Implementation and Evaluation of Electroglottograph System (전기성문전도(EGG) 시스템의 개발 및 평가)

  • 김기련;김광년;왕수건;허승덕;이승훈;전계록;최병철;정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.343-349
    • /
    • 2004
  • Electroglottograph(EGG) is a signal recorded from the vocal cord vibration by measuring electrical impedance across the vocal folds through the neck skin. The purpose of this study was to develop EGG system and to evaluate possibility for the application on speech analysis and laryngeal disease diagnosis. EGG system was composed of two pairs of ring electrodes, tuned amplifier, phase sensitive detector, low pass filter, and auto-gain controller. It was designed to extract electric impedance after detecting by amplitude modulation method with 2.7MHz carrier signal. Extracted signals were transmitted through line-in of PC sound card, sampled and quantized. Closed Quotient(CQ), Speed Quotient(SQ), Speed Index(SI), fundamental frequency of vocal cord vibration(F0), pitch variability of vocal fold vibration (Jitter), and peak-to-peak amplitude variability of vocal fold vibration(Shimmer) were analyzed as EGG parameters. Experimental results were as follows: the faster vocal fold vibration, the higher values in CQ parameter and the lower values in SQ and SI parameters. EGG and speech signals had the same fundamental frequency. CQ, SQ, and SI were significantly different between normal subjects and patients with laryngeal cancer. These results suggest that it is possible to implement portable EGG system to monitor the function of vocal cord and to test functional changes of the glottis.