• Title/Summary/Keyword: 슬럼프테스트

Search Result 3, Processing Time 0.015 seconds

A Study on Quantitative Supply of Sewage Sludge for Co-Incineration of Municipal Solid Waste and Sewage Sludge (하수슬러지와 생활폐기물 혼합소각시 하수슬러지 정량공급에 관한 연구 - Batch Test 중심으로)

  • Cho, Jae-Beom;Kim, Woo-Gu;Yeon, Kyeong-Ho;Shin, Jung-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.64-69
    • /
    • 2013
  • The various promotion countermeasures such as solidification, carbonization, and the creation of cement materials have been considered to existing treatment methods such as incineration and the creation of composts, since direct landfill was prohibited for encouraging the recycling based on the sludge treatment on land. The Main objective of this study is to investigate the feasibility of co-incineration for MSW (municipal solid waste) and SS (sewage sludge) through the quantitative supply of sewage sludge. In this study, optimum water content to operate normally incinerator is 85%. In order to increase the workability of sewage sludge, it is necessary to supply properly water. In the case study of sites, optimum water content is 87% due to the water evaporation. Therefore, it was found that the water content up to 87% would be reached the stable operation of co-incinerator on the mixture of municipal waste solid and sewage sludge.

A Evaluation on the Field Application of High Strength Concrete for CFT Column (고강도 CFT용 콘크리트의 현장적용성 평가 및 장기거동 예측)

  • Park, Je Young;Chung, Kyung Soo;Kim, Woo Jae;Lee, Jong In;Kim, Yong Min
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.707-714
    • /
    • 2014
  • CFT (Concrete-Filled Tube) is a type of steel column comprised of steel tube and concrete. Steel tube holds concrete and the concrete inside tube takes charge of compressive load. This study presents structural performance of the CFT column which has 73~100 MPa high strength concrete inside. Fluidity, mechanical compression, pump pressure test in flexible pipe were conducted for understanding properties of the high strength concrete. Material properties were achieved by various experimental tests, such as slump, slump flow, air content, U-box, O-Lot, L-flow. In addition, mock-up tests were conducted to monitor concrete filling, hydration heat, compressive strength. From construction sites in Sang-am dong and University of Seo-kang, long-term behaviors could be effectively predicted in terms of ACI 209 material model considering elastic deformation, shrinkage and creep.

A Study on the Development of Light Emotion Friendly Concrete Block for Efficient Application of Titan-oxide Photocatalyst (이산화티탄 광촉매의 효율적 적용을 위한 LEFC 블록 제작에 관한 연구)

  • Kim, Byoung-Il;Oh, Sang-Keun;Seo, Seung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.120-131
    • /
    • 2019
  • Recently, the level of fine dust and ultrafine dust has reached its highest level, threatening the public's health. If the air purifier was not operated indoors, natural ventilation would not be possible. In this study, photocatalyst is applied to building materials to purify air in a passive manner. In order to use photocatalyst for LEFC(Light Emotion Friendly Concrete), it is necessary to secure self-consolidating capability. Therefore, self-consolidating performance was evaluated by slump test, J-ring test and L-box test with UHPC materials applied. Based on these results, the mixture proportion was determined, and the mechanical performance was evaluated by compressive and flexural tests. Concrete blocks were constructed with a fabrication method that improved the existing process of making LEFC. Also, the concrete block was emptied as a way to reduce the use of expensive photocatalyst. Finally, in order to identify the distribution of TiO2, an EDS analysis was performed.