Treatability Study for the Nightsoil and Septic Tank Sludge by Anaerobic Digestion (혐기성(嫌氣性) 소화방식(消化方式)에 의한 분뇨(糞尿)와 정화조(淨化槽)슬러지의 혼합처리(混合處理) 실험(實驗)에 관한 연구(硏究))

  • Lee, Kwang Ho;Shin, Eung Bai;Ham, Kun Yeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.69-80
    • /
    • 1982
  • This study was performed to increase the treatment efficiency of the existing anaerobic digestion facilities of the nightsoil treatment plants. Bench-scale anaerobic digesters were operated to evaluate the effect of the ratio (7:3 and 9:1) of the mixture of nightsoil and septic tank sludge on treatment efficiency. The laboratory experiments have demonstrated that the ratio of the mixture does have an effect on the organic removal efficiency. The nightsoil to septage ratio of 7 to 3 appears to yield a higher efficiency than the ratio of 9 to 1. The percent removals of 7 to 3 ratio are 87 % BOD, 82 % COD, 66 % TS, and 78 %. VS whereas those of 9 to 1 ratio are 80 % BOD, 80 % COD, 63 % TS, and 76 % VS. This study also showed that the mixed treatment of the nightsoil and septic tank sludge will be possible at the nightsoil treatment plant.

  • PDF

The Study of Advanced Treatment of Sewage Wastewater by the Electro Coagulation and Oxidation System (전기응집산화를 이용한 하수처리장의 고도처리방안 연구)

  • Lim, Jin-Hwan
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.556-562
    • /
    • 2018
  • Due to the enforcement of effluent water regulation the advance sewage treatment system is needed to retrofit and remodelling. In this case the most important issue is the effluent concentrations of TP and there are a lot of system to reduce its concentration. But biological treatment processes have many restrictions to enhance the removal efficiency of TP. In this study the efficient ECO operating condition to improve and retrofit biological sewage wastewater treatment system is as follow; 1) The treatment efficiency of BOD, TN and TP at the current density of $15mA/cm^2$ was higher than the treatment efficiency at $5mA/cm^2$ in the electrodes arranged with Al-SUS(Stainless Steel) regardless of the reaction time, The TP concentration was 0.1 mg/L or less. Especially, when the reaction time was maintained at 10 min, the TP concentration was 0.06 mg/L or less irrespective of the current density. 2) The change of TP concentration is not influenced by the change of current density and rather the concentration of treated water changes according to the reaction time. In the case of electro coagulation reaction, a few seconds to several minutes are required. However, the reaction time of electro coagulation and oxidation was studied to be more than 10 minutes. 3) As a result, it has been studied that the economical current density of the electro coagulation oxidation process for TN and TP treatment of domestic wastewater is $15mA/cm^2$ or less and the reaction time is 10 minutes.

Immobilization of Earthworm Casts to Treat the Waste Sludge Produced from Pulp & Paper Plants as a Biocarrier (제지공정 페슬러지처리용 지렁이 분변토의 담체화 기술)

  • Cho, Wook Sang;Lee, Eun Young;Cho, Nam Hyeuk
    • Clean Technology
    • /
    • v.8 no.3
    • /
    • pp.167-172
    • /
    • 2002
  • The adaptability of earthworm casts produced form the waste sludge of pulp and paper plants for a biocarrier used in the advanced wastewater treatment was investigated. Removal efficiencies of nutrients in the activated sludge technology without carrier were compared with those treated with carrier made of casts under the different conditions such as the composition of the input and kinds of carrier. When the waste water was treated in the activated sludge technology without carriers, removal efficiencies of T-P and T-N were average values of 31% and 52%, respectively. On the contrary, pellet type carrier and pack type carrier increased the removal efficiencies of T-P and T-N by 1.3~1.4 and 1.9~2.0 times, respectively. At the same time, the high removal of T-P and T-N were observed irrespective of the types of carrier in which many kinds of microorganisms were grown. The difference in the removal efficiencies of BOD and COD between the treatment with and without carrier was negligible. According to this research, the carrier made of casts was thought to be highly applicable in the advanced wastewater treatment.

  • PDF

Advanced Treatment of Shipboard Sewage by SBR Process with BM (BM 미생물제제를 이용한 크루즈선 오·폐수 고도처리)

  • Kim, In-Soo;Chang, Jae-Soo;Lee, Eon-Sung;Koh, Sung-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.36 no.8
    • /
    • pp.643-649
    • /
    • 2012
  • Lab scale experiment study was carried out for biological treatment process development in cruise. SBR(Sequence Batch Reactor) process with BM(Beneficial Microorganisms) was investigated for practical application on shipboard sewage treatment. From the results it was suggested that SBR process with BM might be a suitable process for advanced cruise sewage treatment in terms of decrease in T-N and T-P, maintenance of useful microorganisms and control of sludge bulking. By adding BM to SBR system, about 40% of EPS in sludge was increased, about 74% of total nitrogen was reduced and the total phosphorus reduction averaged 75%.

Development of the On-Site Vermicomposting Unit for Sewage Sludge (하수슬러지 지렁이 퇴비화 장치개발에 관한 연구)

  • Kim, Jong-Oh;Lee, Chang-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.1
    • /
    • pp.92-96
    • /
    • 2003
  • The on-site sewage sludge vermicomposting equipment was designed and evaluated on the batch and continuous tests. The vermicomposting equipment was designed to consider the mechanization as well as automation. In terms of performance evaluation of equipment with continuous experiments, the highest treatment rate was found in the condition of 5mm in particle size and 10mm in e feeding height. Also, 20~25kg of earthworm per 50kg of sewage sludge was the most appropriate density of earthworm. In addition, the most effective separation of cast was found when the earthworm breeding box height was 80cm. The performance evaluation on equipment allowed the establishment of earthworm composting capacity of 2ton per a day with a size of $5{\times}3{\times}1m$ and the automatic control devices.

  • PDF

The Effects of Phenol on Biokinetic Coefficient of Multiple Phenol Derivatives of 2,4-Dichlorophenol and 2,4-Dinitrophenol in Activated Sludge Process (활성슬러지공정에서 페놀이 2,4-디클로로페놀과 2,4-디니트로페놀을 함유한 복합페놀폐수의 미생물분해계수에 미치는 영향)

  • Lim, Gye-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.349-353
    • /
    • 1999
  • A study was carried out to see the effects of phenol on the biological degradation of a wastewater containing 2,4-dichlorophenol and 2,4-dinitrophenol and the biodegradation kinetic coefficients of Eckenfelder's modified model for the activated sludge process. The system containing base mix (BM) which was formulated with essential energy sources and nutrients was run down and washed out when 2,4-dichlorophenol and 2,4-dinitrophenol was introduced into the base mix unit without acclimation to phenol. Whereas for the system acclimated to phenol, the treatment efficiency was 91.9% in terms of $BOD_5$ and treatability for each chemical of phenol, 2,4-dichlorophenol, and 2,4-dinitrophenol was 99.8%, 43.3% and 62.5% based on concentration, respectively. Additional BM was added into the combined unit containing phenol, 2,4-dichlorophenol, 2,4-dinitrophenol so that the better treatment efficiency was achieved for each compound. The biokinetic coefficient of Eckenfelder's modified model without phenol acclimation was not estimated because the system did not reach the steady state. Thc coefficient for the phenol acclimation was 12.44 /day, however it was changed as 46.91 /day in addition of both of phenol acclimation and 47 mg/l of BM. The results presented above could be useful for the process design and further study in the field of biodegradation of benzene derivatives.

  • PDF

Removal of Ammonia Nitrogen and Organics from Piggery Wastewater Using BACC Process-I. Comparison of Activated Sludge Process (BACC를 이용한 축산폐수의 암모니아성 질소 및 유기물의 제거 I. 활성슬러지 공정과의 비교)

  • 성기달;류원률;김인환;조무환
    • KSBB Journal
    • /
    • v.16 no.2
    • /
    • pp.133-139
    • /
    • 2001
  • To treat piggery wastewaters containing refractory compounds including nitrogen, biological treatments were investigated. In biological treatment, the removal efficiencies of organics and nitrogen by the activated sludge process and bioreactor using a BACC (Biological Activated Carbon Cartridge) media filled with granular activated carbon were examined. The results were as follows; in the biological process, when the approximate influent BOD concentration of 620 mg/L, through dilution, was treated by the activated sludge process, the process should be operated at a HRT of over 8 days to maintain an effluent BOD concentration of lower than 100 mg/L. In the treatment of piggery wastewater using a BACC bioreactor, when the HRT was 200 hours, the BOD, COD(sub)cr, and TKN removal efficiency of the effluent were 94, 75 and 64.3%, respectively. Comparing the BACC bioreactor with the activated sludge process, when the volumetric loading rate was 0.3 g BOD/L.day, the specific substrate removal rate of BOD was 0.14 g BOD removed/L.day in the activated sludge process which compared with 0.27 g BOD removed/L$.$day in the BACC bioreactor. The BACC bioreactor showed on average a 2-fold higher removal rate and was superior to the activated sludge process in wastewater treatment in terms of variations of loading time and high loading time. Therefore, the BACC process can effectively treat piggery wastewater containing high concentrations of nitrogen and organic compounds.

  • PDF

Degradation of Phenol by Activated Sludge Immobilized with Photo-crosslinked Resin (광경화성 수지에 고정화된 활성슬러지에 의한 페놀 분해)

  • 김선일;윤영재정경훈
    • KSBB Journal
    • /
    • v.11 no.5
    • /
    • pp.577-585
    • /
    • 1996
  • Effects of various factors on the phenol degradation by activated sludge immobilized with the photo-crosslinked resin were investigated. The optimum pH on the degradation of phenol in both free and immobilized activated sludge was 7. When the pH of the reaction was varied from 5 to 10, the relative activity of the phenol degradation by the immobilized activated sludge was higher than that by the free activated sludge. A higher rate of phenol degradation was observed when a bead size was smaller. The phenol degradation in the free activated sludge was inhibited at the 3000 mg/L of phenol, while that in the immobilized activated sludge was maintained at the same concentration for 28 hrs without an inhibition. The degradation rates of phenol were not directly proportional to the increasing amount of immobilized beads dosage, but the phenol degradation was made in a rather short time than that for a free sludge system. The relative activities of the immobilized activated sludge after 7 runs of repeated reactions increased about 8 times as that of the first reaction. The activities for the phenol degradation remained stable for at least 80 days when the immobilized activated sludge was stored at an aerobic condition in the wastewater containing phenol. The loading rate as high as 5.59 kg-pheno1/㎥.d could have been achieved during the continuous treatment of phenol by the immobilized activated sludge.

  • PDF

Development of Ultrasonic Multi-Beam Sludge Meter For Effluent Facilities Automation (정수장에서 배출수 공정 자동화를 위한 초음파 다중빔 슬러지 농도계 개발)

  • Jang, Sang-Bok;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2313-2321
    • /
    • 2014
  • A concentration meter is widely used at purification plants, sewage treatment plants and waste water treatment plants to sort and transfer high concentration sludge and to control the amount of chemical input. This study has been prepared for improving efficiency of operation on sludge processes and to establish a basic for factory automation by accuracy improvement and problem solution of sludge concentration meter. The concentration meter's accuracy and stability is improved by applying multi-beam sensors and minimum deviation linear average filtering. Furthermore maintenance without cut-off of water in sludge operation is possible by detachable sensors. The performance of multi-beam concentration meter has been variously verified by the pilot plant experiment.