• 제목/요약/키워드: 슬래브-기둥 접합부

검색결과 100건 처리시간 0.022초

고강도 재료를 사용한 외부 보-기둥-슬래브 접합부의 지진응답 (Seismic Response of Exterior Beam-Column-Slab connection using High-Strength Materials)

  • 장극관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.343-350
    • /
    • 1999
  • The purpose of this study is to compare the response of the high-strength concrete beam-column-slab subassembly with the response of a normal-strength concrete specimens. Four assemblies were designed 2/3 scale beam-column-slab joint(fc'=240kg/cm2 fc'=700kg/cm2) and tested to investigate seismic behaviour. From the test results 1) flexral cracks emerge to inside of bean deeply for high strength concrete member 2) the high-strength specimens represented stable hysteretic behaviour for the displacement ductility 5.5 but degradation in stiffness and strength and unstable hysteretic behaviors were observed owing to the brittleness of high-strength concrete beyond its range.

  • PDF

구조 실험과 SASW를 이용한 플랫 플레이트 기둥-슬래브접합부에서의 구조적 거동에 관한 연구 (Structural Behavior in Slab-Column Connections with Shear Plate Using Structural Experiment and Non-destructive Test, Spectral Analysis of Surface Waves)

  • 주현지;조영상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.48-51
    • /
    • 2004
  • This paper is to study the response of flat plate slab-column connections consisting of various types of shear reinforcement and steel plate subjected to gravity loadings, mainly punching shear forces using the non-destructive testing, spectral analysis of surface waves and structural experiments. The base specimen failed due to punching shear generated from the gravity. The three other types of slab shear reinforcement and steel plate showed effective in resisting punching shear for these types of connections under gravity loading. This study has focused in evaluating the velocity response of a Surface wave during the early age as the poured concrete specimens have been hardened, the possibility of damage detection in the slab-column connection and the relationship between the punching shear forces and the surface wave velocities under the condition that the punching shear forces had gradually increased until the flat plate slab in slab-column connection had been failed.

  • PDF

중력전단비에 따른 철근콘크리트 플랫 플레이트 골조의 내진 성능 평가 (Seismic Performance of Reinforced Concrete Flat Plate Frames according to Gravity Shear Ratio)

  • 황보진;한상환;박영미
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.3-10
    • /
    • 2010
  • 이 연구에서는 중력 전단비에 따른 철근콘크리트 플랫 플레이트 골조의 내진성능을 평가하였다. 이를 위하여, 이 연구에서는 3층, 7층 골조를 중력하중만 고려하여 설계하고, 대상 건물에 대한 비선형 정적 푸쉬 오버 해석과 비선형 동적 해석을 수행하였다. 그리고 이 연구는 그 비선형 해석에서 중력 전단비의 차이에 따른 뚫림 전단과 파괴 메커니즘을 예측할 수 있도록 제안한 슬래브-기둥 접합부 모델을 사용하였다. 이 연구 결과에 따르면 중력 전단비가 골조의 내진성능에 큰 영향을 미치는 것으로 나타났다. 특히 중력 전단비가 커짐에 따라 골조 접합부의 파괴가 취성적인 파괴를 나타내어 내진 성능이 떨어지는 것으로 나타났다.

RC 플랫 플레이트 골조의 비선형 해석모델 (Nonlinear Analytical Model for RC Flat Plate Frames)

  • 박영미;황보진;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.241-244
    • /
    • 2008
  • RC 플랫 플레이트 골조는 중력저항 시스템으로 설계하고, 횡력저항 시스템인 전단벽이나 모멘트 골조를 같이 사용하는 것이 일반적이다. 그러나 지진하중과 같은 횡하중은 횡력저항 시스템의 변형을 일으키며 일체로 연결된 중력저항 시스템도 예상치 않았던 횡변위가 발생하여, 접합부에서 큰 불균형 모멘트가 발행하게 된다. 따라서 횡하중에 의해 유발된 불균형모멘트의 고려가 필요하며, �躍꼭患� 파괴를 정확하게 예측할 수 있어야 한다. 본 연구는 RC 플랫 플레이트 골조의 내진성능평가를 위하여 슬래브-기둥 접합부의 비선형 거동을 예측하기 위한 해석모델을 개발하였다. 해석모델의 검증을 위하여 중력전단비가 다른 2개의 2경간 플랫 플레이트 구조물의 실험결과와 해석모델의 결과를 비교하였다. 그 결과 개발된 해석모델은 실험체의 뚤림전단파괴 및 파괴모드를 잘 예측하는 것으로 나타났다.

  • PDF

슬래브가 있는 고강도 철근 콘크리트 넓은 보-기둥 접합부의 거동 (Behavior of High Strength Reinforced Concrete Wide Beam-Column Joint with Slab)

  • 최종인;안종문;신성우;박성식;이범식;양지수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.493-498
    • /
    • 2002
  • An experimental investigation was conducted to study the behavior of high-strength RC wide beam-column joints with slab subjected to reversed cyclic loads under constant axial load. Six half scale interior wide beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including three specimens without slab and three specimens with slab. The primary variables were compressive strength of concrete( $f_{ck}$ =240, 500kgf/c $m^2$), the ratio of the column-to-beam flexural capacity( $M_{r}$=2$\Sigma$ $M_{c}$$\Sigma$ $M_{b}$ ; 0.77-2.26), extended length of the column concrete($\ell$$_{d}$ ; 0, 9.6, 30cm), ratio of the column-to-beam width(b/H ; 1.54, 1.67). Test results are shown that (1) the behavior of specimen using high-strength concrete satisfied the required minimum ductile capacity according to increase the compressive strength, (2). In the design of the wide beam-column joints, one should be consider the effects of slab stiffness which is ignored in the current design code and practice.ice.e.e.

  • PDF

파괴 메커니즘을 고려한 내부 포스트텐션 플랫 플레이트 슬래브-기둥 접합부의 강도식 평가 (Strength of Interior Post-Tensioned Flat Plate Slab-Column Connection based on Failure Mechanism)

  • 김민남;하상수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.126-129
    • /
    • 2006
  • A bending moment $M_u$ transferred at slab-column connection is resisted at the slab critical section by flexure and shear. The ACI 318-05 Building Code(1) gives an empirical equation for the fraction ${\gamma}_{\upsilon}$ of the moment $M_u$ to be transferred by shear at the slab critical section at d/2 from the column face and also the effective wide(c+3h). The equation is based on tests of interior slab-column connections without shear reinforcement. In order to investigate the data eight test specimens were examined. The test shows that increased slab load substantially reduces both the unbalanced moment capacity and the lateral drift capacity of the connection. Especially, the specimens with the bottom reinforcement existence and nonexistence, appears remarkable differences. Studies also show that the code equation for ${\gamma}_{\upsilon}$ does not apply to all cases. The purpose of this study is to compare the test results with present ACI 318-05 Building Code provisions for design of slab-column connections and with the analysis of the experimental data for a new limitation of strength equation without shear reinforcement and bottom reinforcement.

  • PDF

한계상태모델을 이용한 철근콘크리트와 포스트텐션 무량판의 통합해석 (Generalized Analysis of RC and PT Flat Plates Using Limit State Model)

  • 강현구;나창순
    • 콘크리트학회논문집
    • /
    • 제21권5호
    • /
    • pp.599-609
    • /
    • 2009
  • 2층 규모의 철근콘트리트조 및 포스트텐션조 무량판구조를 1/3 스케일로 축소하여 제작한 실험체의 진동대 실험 결과를 바탕으로 무량판구조의 모델링 기법을 향상하고자 하는 연구를 수행하였다. 이 연구에서 적용한 모델링 방법은 슬래브의 휨모멘트에 의한 휨파괴, 불균형모멘트의 전달에 의한 휨파괴 및 펀칭전단파괴에 의한 슬래브-기둥 접합부의 모멘트 전달능력 상실등의 영향을 반영하는 매우 포괄적인 구조해석 방식이다. 펀칭전단파괴에 대해서는 중력비와 층간변위각에 기초한 한계상태 모델이 적용되었다. 이 논문에서 제안된 비선형 모델은 무량판구조의 진동대 실험 결과와 잘 부합하는 것으로 나타났다.

이동 평균법을 이용한 고층 건물의 부등축소량 보정 기법 (Average Correction for Compensation of Differential Column Shortening in High-rise Buildings)

  • 박성우;최세운;박효선
    • 한국전산구조공학회논문집
    • /
    • 제23권4호
    • /
    • pp.395-401
    • /
    • 2010
  • 시간이 지남에 따라 건물의 수직부재가 수축하는 것을 기둥축소라고 한다. 건물의 고층화 및 비정형화 추세 때문에 수직부재들에 작용하는 축하중 크기 간의 차이를 피할 수 없게 되며, 이의 영향으로 인접 수직부재 간의 축방향 축소량이 차이가 나게 된다. 이러한 부등축소량은 수직부재와 수평부재의 접합부에 추가적인 응력을 유발시키거나 슬래브의 기울어짐 또는 간벽이나 창호 등 비구조재의 사용성에 문제를 초래하게 된다. 이러한 부등축소량의 영향을 감소시키기 위하여 시공 중 수직부재의 설치 시 예측된 보정을 하게 된다. 보정의 합리성은 각 부재별 축소량의 정확한 예측과 예측된 축소량을 이용한 각 부재들의 합리적 보정량 산정에 있다. 부등축소량의 예측은 점점 더 정확해지고 있으나 보정 기법에 관한 연구는 거의 없다. 따라서 본 논문에서는 이동 평균법을 사용한 보정 기법과 보정하면서 발생하는 오차에 대한 합리적인 제한조건을 제시하였으며, 제한조건의 변화와 보정 그룹 수의 관계를 살펴봄으로써 제한조건 설정의 객관적인 판단 기준이 되었다. 그리고 이전에 연구되어진 SA 알고리즘을 사용한 최적 보정 기법과 결과를 비교해 봄으로써 이동 평균법 보정 기법의 효과를 검증하였다.

단부 보강한 합성보(에코거더)시스템의 구조성능에 관한 실험적 연구 (Experimental Study on Structural Performance of End-reinforced Steel-beam system(Eco-girder))

  • 채흥석;류재용;정경수;문영민;최성모
    • 한국강구조학회 논문집
    • /
    • 제22권6호
    • /
    • pp.533-541
    • /
    • 2010
  • H형강 보는 기둥 사이에 설치되어 건물의 각 층 바닥인 슬래브를 지지하기 위해 널리 사용되고 있다. 그러나, H형강 보의 경우 접합부가 고정단이면서 등분포하중 작용시 양 단부에 발생하는 휨 모멘트는 중앙부에 발생하는 모멘트에 비해 약 2배가량 크다. 보는 최대 모멘트에 의해 설계가 이루어지기 때문에 보 춤이 커지게 되고, 이로 인하여 각 층의 가용 공간이 줄어드는 문제점이 있다. 이를 개선하기 위해, 최대 휨 모멘트가 발생하는 H형강 보 양 단부만을 별도로 보강하면, 보 중앙부에서 발생하는 휨 모멘트로 보를 설계할 수 있다. 따라서, 단부 보강한 철골보(Eco-girder)의 구조적 성능을 분석하기 위해, 단부 보강 강판의 용도, 철근 보강, 하중전달방법 등을 변수로 하여 4개의 실험체를 제작하여 구조성능실험을 수행하였다.

U-형 복합보의 춤 변화에 따른 구조성능에 관한 실험적 연구 (An Experimental study on the Structural Performance by the Depth Variation of Capacity of U-shaped composite Beam)

  • 하상수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.111-118
    • /
    • 2020
  • 본 연구에 사용된 U-형 복합보는 슬래브는 철근콘크리트구조로 되어 있고, 슬래브를 지지해 주는 보는 철골구조와 철근콘크리트구조, 그리고 U-형 강판으로 이루어져 있다. U-형 복합보는 시공성이 우수하고 낮은 층고와 장경간이 가능하기 때문에 공작물 주차장으로 사용하기 위한 목적으로 개발되었다. 시공성 향상을 위해 U-형 복합보 단부는 규격화된 H형강으로 계획하여 기둥에 직접 접합시키고, 강재 물량을 감소시키기 위해 U-형 복합보의 중간 부분에는 H형강 대신 얇은 강판(t=6)을 사용하여 U자형 형태로 접은 U-형 강판으로 구성되어 있다. U형 강판이 위치하는 복합보 중앙부에는 보의 춤을 작게 계획함으로서 공작물 주차장의 제한 높이에 만족하도록 계획할 수 있다. 낮은 보의 춤은 층고 단축에는 유리하지만 휨성능에는 저해 요인이 되기 때문에 춤 변화에 따른 구조성능을 파악하는 것이 중요하다. 또한, U-형 복합보는 철골구조와 철근콘크리트구조 및 U-형 강판이 혼합되어 있기 때문에 일체성 확보가 구조성능을 확보하는데 큰 영향을 준다. 따라서 본 연구에서는 U-형 복합보의 춤을 변화에 따른 구조성능을 파악하기 위한 구조실험을 실시하였다. 실험체는 일반주차장용으로 계획된 실험체를 기준실험체로 하여 춤을 변화시킨 2개의 실험체를 포함하여 총 3개를 계획하였다. 실험결과 춤을 크게 계획한 실험체가 기준실험체보다 항복강도, 최대강도, 에너지 등 구조성능이 우수하게 나타났다.