• Title/Summary/Keyword: 슬래브 기둥 접합부

Search Result 100, Processing Time 0.022 seconds

Deformability of Flat Plate Subjected to Unbalanced Moment (불균형 휨모멘트를 받는 플랫 플레이트의 변형능력)

  • Choi, Kyoung-Kyu;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.482-493
    • /
    • 2003
  • Flat plate structures subjected to lateral load have less deformability than conventional moment frames, due to the brittle failure of plate-column connection. In the present study, parametric study using nonlinear finite element analysis was performed to investigate the deformability of flat plates. The numerical results show that as number of continuous spans increases, the deformability of flat plates considerably decreases. Therefore, existing experiments using sub-assemblages with 1 or 2 spans may overestimate the deformability of flat plates, and current design provisions based on the experiments may not be accurate in estimating the deformability. A design method estimating the deformability was developed on the basis of numerical results, and verified by comparison with existing experiment. In the proposed method, the effects of primary design parameters such as direct shear force, punching shear capacity, aspect ratio of connection, number of spans, and initial stiffness of plate can be considered.

Strut-Tie Model Approach Associated with 3-Dimensional Grid Elements for Design of Structural Concrete - (II) Validity Evaluation (3차원 격자요소를 활용한 콘크리트 구조부재의 스트럿-타이 모델 설계 방법 - (II) 타당성 평가)

  • Kim, Byung Hun;Yun, Young Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.437-446
    • /
    • 2014
  • In this study, the ultimate strengths of 13 slab-column joints and 51 torsional beams were evaluated to verify the validity of the strut-tie model approach presented in the companion paper. In addition, the design of the bridge pier subjected to multiple load combinations with longitudinal and lateral loads was conducted. The analysis results were compared with those by the provisions of BS 8110, ACI 318, and AASHTO-LRFD. The design results of the bridge pier were also compared with those by the provisions of ACI 318's sectional design method and AASHTO-LRFD's strut-tie model method.

Analytical Study on Relationship Between Moment Transfer Efficiency of a Beam Web and Strain Concentration at Steel Moment Connections (철골 모멘트 접합부에서 웨브의 모멘트 전달효율과 변형도 집중과의 관계에 관한 해석적 연구)

  • Kim, Young Ju;Oh, Sang Hoon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.695-703
    • /
    • 2004
  • In this paper, the results of monotonic loading analysis with four steel models and one composite model were shown. The effect that moment transfer efficiency of a web and strain concentration at a steel beam-to-column connections was investigated. Analysis results showed that the moment transfer efficiency of the analytical model with box-column was poor when comparing to model with H-column due to out-of-plane deformation of the box-column flange. The presence of scallop, thin plate of box column and floor slabs was also a reason of the decrease of moment transfer efficiency, which would result in a potential fracture of the steel beam-to-column connections. Analytical results were compared with experimental results based on previous test. As a result, the deformation capacity of connections with a box-column or a floor slab decreased due to the poor moment transfer efficiency and the strain concentration of beam flange in the vicinity of the steel beam-to-column connections based on the experimental data.

Structural Characteristic of Beam-to-Column Connections in Rectangular CFT Structures Considering Concrete Filling (충전성을 개선한 각형CFT 기둥-보 접합부의 구조 특성)

  • Park, Je Young;Lee, Myung Jea
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • CFT structures require a diaphragm to prevent buckling of steel at connections. An outer diaphragm has better concrete filling than a through diaphragm due to a large bore, but due to the larger size than the through diaphragm, it has poorer constructability and cooperation with building equipment. The building structure has a floor slab that was unified with the upper diaphragm, so the outer diaphragm was placed at the upper bound. Moreover, the through diaphragmwas placed at the lower connection to avoid obstruction of the building equipment. The CFT structure with the improved concrete filling showed the same structural behavior as the CFT structure with the use of the same type of diaphragms at the upper and lower connections.

Strength of Interior Plat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부의 강도산정모델)

  • 최경규;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.961-972
    • /
    • 2002
  • Flat plate structures under lateral load are susceptible to the brittle shear failure of plate-column connection. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, according to previous studies, current design methods do not accurately estimate the strength of plate-column connection. In the present study, parametric study using nonlinear finite element analysis was performed for interior connections. Based on the numerical results, a design method for the connection was developed. At the critical sections around the connection coexist flexural moment and shear developed by lateral and gravity loads, and maximum allowable eccentric shear stresses were proposed based on the interactions between the flexural moment and shear, The proposed method can precisely predict the strength of the connection, compared with the current design provisions. The predictability of the proposed method was verified by the comparisons with existing experiments and nonlinear numerical analyses.

Effective Compressive Strength of Corner Columns with Intervening Normal Strength Slabs (일반강도 슬래브로 간섭받은 모서리 기둥의 유효압축강도)

  • Lee, Joo-Ha
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.122-129
    • /
    • 2015
  • In this study, a prediction model for the effective compressive strength of corner columns with intervening normal strength concrete slabs was developed. A structural analogy between high-strength concrete column-normal strength concrete slab joint and brick masonry was used to develop the prediction model. In addition, the aspect ratio of slab thickness to column dimension was considered in the models. The reliability of the new prediction model was evaluated by comparison with experimental results and its superiority was demonstrated by comparison with previous models proposed by design codes and other researchers. As a result, with average test-to-predicted ratios of 1.09, a standard deviation of 0.15, the newly developed equation provided superior predictions in terms of accuracy and consistency over all of the existing effective strength prediction approaches including KCI structural concrete design code (2012).

An Experimental Study on Structural Performance of H-Steel or SRC Column and Flat Plate Slab Connection (플랫 플레이트 슬래브와 H형강 기둥 접합부의 구조 성능에 관한 실험적 연구)

  • Yoon, Myung-Ho;Lee, Yoon-Hee;Ryu, Hong-Sik;Kim, Jin-Won
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. We carried out to evaluate the punching shear performance of H-steel or SRC column + RC slab system for vertical load and lateral load. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities ect. - are obtained and evaluated. In this paper as a shear reinforcement for supporting region of plate closed stirrup type and shear band are used, and their test results are compared.

An Experimental Research on the Shear Friction Behavior of Beam-Column Joints of Partial Precast Concrete Structures (부분PC 보-기둥 접합부의 전단 마찰 거동에 관한 실험 연구)

  • Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • An experimental program was initiated to investigate the structural capacity of PC (Precast Concrete) beam-column joints used for the underground parking structure. Static testing of 4 typical PC beam-column joints specimens was conducted. Specimens were designed to span a range of parameters typically encountered for such members, based on findings from the survey of existing PC joint details used in the construction fields in Korea. The specimens were four by their joint types and testing parameters. The specific structural behavior germane to each specimen, and general observations on overall member behavior as a function of the considered parameters, are reported. From the results of tests on four PC joints specimens, the beam-column joints of PC structure used for the underground parking building was found to have similar structural capacities when comparing to the cast-in-place concrete system.

Structural Behaviour of Beam-to-Concrete Filled Steel Tube Column Pin Connections (콘크리트충전 각형강관기둥-보 핀접합부의 거동에 관한 실험적 연구)

  • Kim, Cheol-Hwan;Lee, Eun-Taik;Kim, Seong-Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.4 s.47
    • /
    • pp.437-443
    • /
    • 2000
  • In order to clarify the behavior of beam-to-concrete filled steel tube column under cyclic loading condition, experimental studies were carried out on shear connections. Test parameters of this study are the width-to-thickness ratio and the effect on beams with or without slab and diaphragm. Test results show that the moment-rotation relationships of connections without slab are in the range of AISC regulation of pinned connections and the rotation capacity of connection is dependent upon the width-to-thickness ratio of the column.

  • PDF

Development for Connection Details between Flat Plate Slab and H-Steel Column (무량판 슬래브와 H형강 기둥 접합부 상세 개발)

  • Yoon, Myung-Ho;Lee, Yoon-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.22-27
    • /
    • 2014
  • The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.