• Title/Summary/Keyword: 슬개건

Search Result 50, Processing Time 0.023 seconds

The Result of the Arthroscopic Reconstruction of Posterior Cruciate Ligament with Autogenous or Allogenous Graft (자가 또는 동종 이식물을 이용한 후방 십자 인대 재건술 후의 결과)

  • Chon Je-Gyun;Kim Eui-Soon;Choi Bo-Yeul;Yoon Chang-Hoon;Lee Jeong-Woung;Sun Doo-Hoon;Moon Myung-Sang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.74-79
    • /
    • 2001
  • Purpose : The purpose of this study is to evaluate the clinical results after arthroscopic PCL reconstruction and to compare the clinical results after arthroscopic PCL reconstruction using BPTB(bone patellar tendon bone) autograft(Group I : 11 cases), Achilles tendon allograft(Group II : 7 cases) and BPTB allograft(Group 111.6 cases). Materials and Methods : We reviewed the result of 24 patients who had been managed with arthroscopic reconstruction using different graft materials such as BPTB autograft, Achilles tendon allograft and BPTB allograft. Twenty-four patients(average age, 37 years) with PCL rupture were retrospectively evaluated more than one year(average, 31 months) after having arthroscopic posterior cruciate ligament reconstruction. The clinical results were evaluated by IKDC ligament standard evaluation form, using $KT-2000^{TM}$ knee ligament arthrometer and also evaluated Lysholm knee scoring scale. Results : The final evaluation was nearly normal in 11 patients($45\%$ in Group I, $43\%$ in Group II, $50\%$ in Group III). The corrected posterior sagging was abnormal(side to side difference more than 6mm) in 8 patients($36\%$ in Group I, $29\%$ in Group II, $33\%$ in Group III). We could not find significant difference among three groups by IKDC scale. Conclusion : Comparing with other reports, our overall results were not satisfactory. And also, we could not find any remarkable difference among the three groups. Further research is necessary to evaluate new surgical approaches as well as improved techniques for capsular and collateral ligament injuries.

  • PDF

Intraoperative and Postoperative Complications After Arthroscopic Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft (자가 골-슬개건-골을 이용한 관절경적 전방십자인대 재건술의 수술 중 및 수술 후 합병증)

  • Kim, Kyung-Tae;Lee, Song;Jeong, Soon-Young;Kim, Hyun-Soo;Park, Jun-Seong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • Purpose : Evaluation and analysis of the incidence and causes of intraoperative and postoperative complications after arthoscopic anterior cruciate ligament(ACL) reconstruction using bone-patella. tendon-bone (BPTB) auto graft. Materials and Methods : We reviewed 85 cases of arthroscopic ACL reconstruction using BPTB autograft which had been followed up for more than 1 year. Intraoperative complications had been recorded and corrected during the operation. Postoperative complications were analyzed and compared between 3 groups which were classified by the last follow-up period after the operation. Results : There were a few intraoperative complications including patellar fracture(1 case), contamination of harvested graft(1 case), impingement of graft(2 cases), blow-out of tile posterior wall of the femoral tunnel(1 case) and intraarticular retraction of the screw(1 case). The result of the comparison of postoperative complications among the groups shows that the incidence of anterior knee pain, donor site pain and patellofemoral crepitation were significantly decreased after 2 years. But there was no significant decrease in these complications after 3 years. Conclusion : Intraoperative complications after arthroscopic ACL reconstruction using BPTB autograft were due to incorrect technique and carelessness of the operation team, and can be prevented by improvement of surgical technique and accumulation of experience. Postoperative complication were somewhat unavoidable but gradually improved with time; hence, we should consider it for the selection of graft donor.

  • PDF

Second-Look Arthroscopy after ACL Reconstruction with Autograft Tendons (자가건을 이용한 전방 십자 인대 재건술 후 이차 관절경 검사)

  • Fang, Zhen-Zhu;Yoo, Moon-Jib;Kim, Myung-Ho;Bahng, Seung-Chu;Kim, You-Jin;Park, Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.38-44
    • /
    • 2007
  • Purpose: To evaluate status of reconstructed ACL and changes around graft through second-look arthroscopy after arthroscopic reconstruction of the ACL with autograft tendons. Material and Methods: Between Jun. 2003 and Feb. 2007, the second look arthroscopy was performed on 22 cases. Second-look arthroscopy was conducted on average 15.1 $(7\sim31)$ months after reconstruction. 15 cases received hamstring tendon autograft, 7 cases received bone-patellar tendonbone autograft. We measured graft tension using displacement by probing, synovial coverage by visual analysis at second-look arthroscopy The assay in Lysholm score, Lachmann test and KT-2000 arthrometer were evaluated status of reconstructed ACL. Results: The hamstring tendon group showed normal tension in 11 cases and lax tension in 4 cases. The patellar tendon group showed normal tension in 3 cases, lax tension in 2 cases and partial tear in 2 cases. In the hamstring tendon group, synovial coverage was good in 11 cases, half in 3 cases and pale in 1 case, and the bone-patellar tendon-bone group was good in 4 cases and half in 3 cases. The patellar tendon group was superior to the hamstring tendon group in Lysholm score (p<0.05), but insignificance difference in KT-2000 arthrometer results statistically. Conclusion: The hamstring tendon group was superior to the bone-patellar tendon-bone group in second-look arthroscopy after ACL reconstruction with autograft tendons results, but long term follow up will be necessary to further evaluated.

  • PDF

슬개건을 이용한 전방 십자 인대 재건술

  • Lee Byung-Il;Choi Hyung-Suk
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.100-105
    • /
    • 2003
  • 자가 중간 1/3 슬개건골을 이용한 관절경적 전방 십자 인대 재건술은 슬관절의 안정성 회복 및 임상적 결과가 비교적 만족 할만 하나 슬개-대퇴간 동통 공여부 감각 소실 또는 저하 등의 슬개골 주위 합병증이 발생하므로 이러한 문제점을 가능한 줄이고 기능적 회복을 도모하는데 이식건 채취 방법에 있어서 분리된 절개를 이용하고 속이 빈 원형의 톱날 기구(Hollowsaw)를 사용함으로써 결과의 향상을 기대 할 수 있을 것으로 사료되나 추후 보다 면밀하고 장기적인 추시 관찰이 됫받침 되어야 할 것이다

  • PDF

Anterior Cruciate Ligament Reconstruction using Hamstring Tendons (슬괵건을 이용한 전방 십자 인대 재건술)

  • Kim, Hyoung-Soo;Kim, Joo-Hak;Ji, Jeong-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.123-131
    • /
    • 2005
  • The central third of the patellar tendon and hamstring tendons(semitendinosus and gracilis) are the most frequently used tissues for intra-articular replacement of the anterior cruciate ligament(ACL). At present, many surgeons consider the central third patellar ten don graft to be the gold standard for replacement of the ACL. Recent prospective studies by Marder et at and Aglietti et al, however, have failed to show any statistically significant differences in knee stability and functional outcome between central third patellar tendon grafts and hamstring tendon grafts. The review of this article is to (1) review the historical use of hamstring tendon grafts for ACL reconstruction; (2) discuss indications for use of hamstring tendon grafts for ACL reconstruction; (3) describe our present operative technique using a combined double-looped semitendinosus and gracilis graft with $RIGIDFIX^{circledR}$ and $INTRAFIX^{circledR}$ and (4) review the results of hamstring ACL reconstructions.

  • PDF

Treatment of Transverse Patella Fracture with Minimally Invasive Load-Sharing Patellar Tendon Suture and Cannulated Screws (최소 침습 기법 슬개건 부하 분산 봉합술과 유관 나사못을 이용한 슬개골 횡골절의 치료)

  • Lee, Beom-Seok;Park, Byeong-Mun;Yang, Bong-Seok;Kim, Kyu-Wan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.540-545
    • /
    • 2021
  • A transverse fracture is the most common type of displaced patella fracture requiring surgery. These fractures are commonly fixed with parallel Kirschner wires or screws that cross the fracture line, often with an additional tension band. Nevertheless, conventional fixation methods of patella fractures have prevalent complications caused by the protrusion of wires or pins. These complications necessitate additional surgery for hardware removal, increase medical cost, and can limit the function of the knee joint. This paper reports cases treated with a minimally invasive load-sharing percutaneous suture of the patella tendon. The procedure provides reliable fixation for transverse patella fractures, minimizes soft tissue injuries, preserves blood flow, and reduces postoperative pain. In addition, the procedure also reduces the irritation and pain caused by the internal fixture, thereby reducing the risk of restricted knee joint movement.

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF

Postoperative Complications After Arthroscopic Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft (자가 슬개건을 이용한 전방 십자 인대 재건술의 수술 후 합병증)

  • Zhu, Fang Zhen;Yoo, Moon-Jib;Kim, Myung-Ho;Park, Hee-Gon;Bahng, Seung-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.122-127
    • /
    • 2008
  • Purpose: Evaluation and analysis of the incidence of postoperative complications after arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. Materials and Methods: We reviewed 172 cases of arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft in anterior cruciate ligament tear without meniscal injury. We performed Lysholm knee score and KT-2000 testing, simple radiograph, physical examination as evaluation factor. Also, around knee pain, swelling, limitation of motion, patellofemoral crepitation, paresthesia and pain on kneeling were evaluated. Results: The average follow up period was 49.8 months. In 172 patients, 148 males and 26 femlaes were evaluated. The average age was 34.4 years. The Lysholm knee score improved from 51.9 points preoperatively to 90.8 points at final follow up. Clinical outcome was excellent in 83%, good in 11%, fair in 4% and poor in 2%. There were many cases of complications, 24 cases (14%) of around knee pain, 12 cases (7%) of swelling, 45 cases (26.2%) of patellofemoral crepitation, 52 cases (30%) of donor site paresthesia, 65 cases (38%) of pain on kneeling, 10 cases (5.8%) of limitation of motion at extension, 13 cases (8%) of limitation of motion at flexion and 2cases (1.2%) of patellar fracture. Conclusion: Although arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone had good clinical results, many complications were noted. Some factors in surgical technique were suspected to be related to the complications and long term follow up will be necessary to further evaluated.

  • PDF

A Comparison of the Results of BPTB and Hamstring ACL Autograft - Function, Stability & Tunnel Expansion - (골-슬개건-골 및 슬괵건을 이용한 전방 십자 인대 재건술의 비교 - 술후 슬관절의 기능, 안정성 및 대퇴, 경골터널 확장정도에 대하여 -)

  • Jung Young Bok;Tae Suk-Kee;Lim Jung Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • Purpose : The purpose of this study was to compare the results of ACL reconstruction using bone-patellar tendon-bone to hamstring. Materials and Methods : Thirty-two ACL reconstructions with autogenous BPTB and eighteen reconstructions with hamstring were compared in terms of functional outcome, stability and tunnel expansion. Results : The functional score of BPTB group was higher than hamstring group in OAK(Orthopadishe Arbeitsguppe Knie) and IKDC(International Knee Documentation Committee) system. In BPTB group, OAK scores were 71.6$({\pm}10.0)$ preoperatively and 88.5$({\pm}7.9)$ finally. In hamstring group, OAK scores were 73.9$({\pm}11.5)$ and 82.5$({\pm}12.9)$ respectively. There was no difference in stability checked by either $KT-1000^{TM}$ or stress view. Anterior tibial translation measured by $KT-1000^{TM}$ were 2.4$({\pm}1.8)$mm in BPTB and 2.3$({\pm}2.4)$mm in hamstring group. Anterior tibial translation in stress view were 2.8$({\pm}3.4)$mm in BPTB and 2.8$({\pm}2.5)$mm in hamstring group. There was no difference in tibial tunnel expansion but femoral tunnel was more enlarged in hamstring group than BPTB (P=0.03). Conclusion : As there was no difference in stability between two groups, it seems prudent to select either graft defend on such factors as anterior knee pain, skeletal maturity and cosmetic concern. Tunnel expansion seems not to affect stability, but further study is needed to confirm that decrease of which might improve stability.

  • PDF