• Title/Summary/Keyword: 스펙트럼 패턴

Search Result 197, Processing Time 0.03 seconds

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Comparisons of 1-Hour-Averaged Surface Temperatures from High-Resolution Reanalysis Data and Surface Observations (고해상도 재분석자료와 관측소 1시간 평균 지상 온도 비교)

  • Song, Hyunggyu;Youn, Daeok
    • Journal of the Korean earth science society
    • /
    • v.41 no.2
    • /
    • pp.95-110
    • /
    • 2020
  • Comparisons between two different surface temperatures from high-resolution ECMWF ReAnalysis 5 (ERA5) and Automated Synoptic Observing System (ASOS) observations were performed to investigate the reliability of the new reanalysis data over South Korea. As ERA5 has been recently produced and provided to the public, it will be highly used in various research fields. The analysis period in this study is limited to 1999-2018 because regularly recorded hourly data have been provided for 61 ASOS stations since 1999. Topographic characteristics of the 61 ASOS locations are classified as inland, coastal, and mountain based on Digital Elevation Model (DEM) data. The spatial distributions of whole period time-averaged temperatures for ASOS and ERA5 were similar without significant differences in their values. Scatter plots between ASOS and ERA5 for three different periods of yearlong, summer, and winter confirmed the characteristics of seasonal variability, also shown in the time-series of monthly error probability density functions (PDFs). Statistical indices NMB, RMSE, R, and IOA were adopted to quantify the temperature differences, which showed no significant differences in all indices, as R and IOA were all close to 0.99. In particular, the daily mean temperature differences based on 1-hour-averaged temperature had a smaller error than the classical daily mean temperature differences, showing a higher correlation between the two data. To check if the complex topography inside one ERA5 grid cell is related to the temperature differences, the kurtosis and skewness values of 90-m DEM PDFs in a ERA5 grid cell were compared to the one-year period amplitude among those of the power spectrum in the time-series of monthly temperature error PDFs at each station, showing positive correlations. The results account for the topographic effect as one of the largest possible drivers of the difference between ASOS and ERA5.

Monitoring North Korea Nuclear Tests: Comparison of 1st and 2nd Tests (북한 핵실험 모니터링 : 1, 2차 비교)

  • Chi, Heon-Cheol;Park, Jung-Ho;Kim, Geun-Young;Che, Il-Young;Sheen, Dong-Hoon;Shin, Jin-Soo;Cho, Chang-Soo;Lee, Hee-Il
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.243-248
    • /
    • 2010
  • Two suspicious events, which were claimed as underground nuclear tests by North Korea, were detected in the northern Korean Peninsula on October 9, 2006 and May 25, 2009. The KIGAM and Korea-China Joint seismic stations are distributed uniformly along the boundaries between North Korea and adjacent countries. In this study, the data from broadband stations with the distance of 200 to 550 km from the test site are used to analyze and compare two nuclear tests of North Korea. By comparing the time differences of the Pn-wave arrival times of 1st and 2nd tests at multiple stations, the relative locations of two test sites could be calculated precisely. From the geometrical calculation with the velocity of Pn wave $V_{Pn}$ = 8 km/s, the 2nd test site is estimated to move in the WNW direction from 1st one with the distance of 2 km. Body wave magnitude, mb of the 2nd test, which was announced officially as the network average of 4.5, varies widely with the directional location of stations from 4.1 to 5.2. The magnitude obtained from Lg wave, $m_b$(Lg), shows less variation between 4.3 to 4.7 with the average of 4.6. The moving-window spectra of time traces of 1st and 2nd tests show very similar pattern with different scale level. In addition, the corner frequencies of P wave of 1st and 2nd tests at each station show no or negligible difference. This indicates the burial depths of two tests might be very similar. The relative yield amount of the 2nd test is estimated 8 times larger than that of the 1st from the weighted average of ground-velocity amplitude ratios.

A Study on the Identification of Animal Hair in Food (식품 중 동물 털 이물의 판별법 연구)

  • Lee, Jae-Hwang;Park, Young-Eun;Lim, Byung-Chul;Kim, Ju-Shin;Choi, Jong-Hyun;Kang, Tae Sun;Lee, Jin-Ha;Kwon, Kisung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.1
    • /
    • pp.57-63
    • /
    • 2017
  • Foreign materials with a variety of types and sizes are found in food; thus, extraordinary efforts and various analytical methods are required to identify the types of foreign materials and to find out accurate causes of how they unintentionally enter food. In this study, human, cow, pig, mouse, duck, goose, dog, and cat were chosen as various types of animal hairs because they can be frequently incorporated into food during its production or consumption step. We morphologically analyzed them using stereoscopic, optical, SUMP method, and scanning electron microscopes, showing differences in each type. In addition, X-ray fluorescence spectrometer (XRF) was used to analysis chemical compositions ($^{11}Na{\sim}^{92}U$, Mass%) of samples. As a result, we observed that mammalian hairs were mainly composed of sulfur. Organic compounds of samples were further analyzed by fourier transform infrared spectroscopy (FT-IR) that can compare spectra of given materials; however, this method did not show significant differences in each sample. In this study, we suggest a rapid method for the identification of the causes and types of foreign materials in food.

The Analysis of Spectral characteristics of Water Quality Factors Uisng Airborne MSS Data (Airborne MSS 자료를 이용한 수질인자의 분광특성 분석)

  • Dong-Ho Jang;Gi-Ho Jo;Kwang-Hoon Chi
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.296-306
    • /
    • 1998
  • Airborne MSS data is regarded as a potentially effective data source for the measurement of water quality and for the environmental change of water bodies. In this study, we measured the radiance reflectance by using multi-spectral image of low resolution camera(LRC) which will be reached in the multi-purpose satellite(KOMPSAT) to use the data in analyzing water pollution. We also investigated the possibility of extraction of water quality factors in water bodies by using high resolution remote sensing data such as Airborne MSS. Especially, we tried to extract environmental factors related with eutrophication such as chlorophyll-a, suspended sediments and turbidity, and also tried to develop the process technique and the radiance feature of reflectance related with eutrophication. Although it was difficult to explicitly correlate Airborne MSS data with water quality factors due to the insufficient number of ground truth data. The results were summarized as follows: First, the spectrum of sun's rays which reaches the surface of the earth was consistent with visible bands of 0.4${\mu}{\textrm}{m}$~0.7${\mu}{\textrm}{m}$ and about 50% of total quantity of radiation could be found. The spectrum was reached highest at around 0.5${\mu}{\textrm}{m}$ of green spectral band in visible bands. Second, as a result of the radiance reflectance Chlorophyll-a represented high mainly around 0.52${\mu}{\textrm}{m}$ of green spectral band, and suspended sediments and turbidity represented high at 0.8${\mu}{\textrm}{m}$ and at 0.57${\mu}{\textrm}{m}$, respectively. Finally, as a result of the water quality analysis by using Airborne MSS, Chlorophyll-a could have a distribution image after carrying out ratio of B3 and B5 to B7. Band 7 was useful for making the distribution image of suspended sediments. When we carried out PCA, suspended sediments and turbidity had distributions at PC 1 and PC 4 which are similar to the ground data. Above results can be changed according to the change of season and time. Therefore, in order to analyze the environmental factors of water quality by using LRC data more exactly, we need to investigate the ground data and the radiance feature of reflectance of water bodies constantly. For further studies, we will constantly analyze the radiance feature of the surface of water in wafter bodies by measuring the on-the-spot radiance reflectance and using low resolution satellite image(SeaWiFS). We will also gather the data of water quality analysis in water bodies and analyze the pattern of water pollution.

Influences of the Composition on Spectroscopic Characteristics of AlxGa1-xN Thin Films (AlxGa1-xN 박막의 조성이 분광학적 특성에 미치는 영향)

  • Kim, Dae Jung;Kim, Bong Jin;Kim, Duk Hyeon;Lee, Jong Won
    • New Physics: Sae Mulli
    • /
    • v.68 no.12
    • /
    • pp.1281-1287
    • /
    • 2018
  • In this study, $Al_xGa_{1-x}N$ films were grown on (0001) sapphire substrates by using metal-organic chemical vapor deposition (MOCVD). The crystallinity of the grown films was examined with X-ray diffraction (XRD) patterns. The surfaces and the chemical properties of the $Al_xGa_{1-x}N$ films were investigated using atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS), respectively. The optical properties of the $Al_xGa_{1-x}N$ film were studied in a wide photon energy range between 2.0 ~ 8.7 eV by using spectroscopic ellipsometry (SE) at room temperature. The data obtained by using SE were analyzed to find the critical points of the pseudodielectric function spectra, $<{\varepsilon}(E)>=<{\varepsilon}_1(E)>+i<{\varepsilon}_2(E)>$. In addition, the second derivative spectra, $d^2<{\varepsilon}(E)>/dE^2$, of the pseudodielectric function for the $Al_xGa_{1-x}N$ films were numerically calculated to determine the critical points (CPs), such as the $E_0$, $E_1$, and $E_2$ structure. For the four samples (x = 0.18, 0.21, 0.25, 0.29) between a composition of x = 0.18 and x = 0.29, changes in the critical points (blue-shifts) with increasing Al composition at 300 K for the $Al_xGa_{1-x}N$ film were observed via ellipsometric measurements for the first time.

Acoustic characteristics of speech-language pathologists related to their subjective vocal fatigue (언어재활사의 주관적 음성피로도와 관련된 음향적 특성)

  • Jeon, Hyewon;Kim, Jiyoun;Seong, Cheoljae
    • Phonetics and Speech Sciences
    • /
    • v.14 no.3
    • /
    • pp.87-101
    • /
    • 2022
  • In addition to administering a questionnaire (J-survey), which questions individuals on subjective vocal fatigue, voice samples were collected before and after speech-language pathology sessions from 50 female speech-language pathologists in their 20s and 30s in the Daejeon and Chungnam areas. We identified significant differences in Korean Vocal Fatigue Index scores between the fatigue and non-fatigue groups, with the most prominent differences in sections one and two. Regarding acoustic phonetic characteristics, both groups showed a pattern in which low-frequency band energy was relatively low, and high-frequency band energy was increased after the treatment sessions. This trend was well reflected in the low-to-high ratio of vowels, slope LTAS, energy in the third formant, and energy in the 4,000-8,000 Hz range. A difference between the groups was observed only in the vowel energy of the low-frequency band (0-4,000 Hz) before treatment, with the non-fatigue group having a higher value than the fatigue group. This characteristic could be interpreted as a result of voice abuse and higher muscle tonus caused by long-term voice work. The perturbation parameter and shimmer local was lowered in the non-fatigue group after treatment, and the noise-to-harmonics ratio (NHR) was lowered in both groups following treatment. The decrease in NHR and the fall of shimmer local could be attributed to vocal cord hypertension, but it could be concluded that the effective voice use of speech-language pathologists also contributed to this effect, especially in the non-fatigue group. In the case of the non-fatigue group, the rhamonics-to-noise ratio increased significantly after treatment, indicating that the harmonic structure was more stable after treatment.