• Title/Summary/Keyword: 스텐레스 강

Search Result 15, Processing Time 0.016 seconds

A study on the effect of ultrasonic beam skewing based on theoretical model approach in CCSS (원심 주조 스텐레스 강에서의 이론적 모델을 통한 Beam Skewing 영향 고찰)

  • Lee, S.L.;Lim, H.T.;Lee, Y.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.24-28
    • /
    • 1990
  • Centrifugally Cast Stainless Steel generally shows similar structure to the weld in austenitic stainless steel in the point of casting. When examining this material ultrasonically, the beam does not generally propagate straightforward but rather deviates from its original direction and this phenomenon called skewing is originally caused by anisotropic material. In order to calculate the beam skewing effect theoretically, work has been performed based on a model approach which has regarded material itself as having been composed of multi-layered columnar dendrite structure and the result was compared with the one from experiment. The result from both theory and experiment showed good correlation and ultrasonic beam showed the least skewing with around 45 degree incident angle.

  • PDF

Image Technique of Surface Defects by Using Photoacoustic Signal Processing (광음향 신호처리를 이용한 표면결함의 영상 기술)

  • Yi, Chong-Ho;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.45-49
    • /
    • 1994
  • In this paper, photoacoustic image processing system was constructed by using 2W CW $CO_{2}$ laser of $10.6{\mu}m$ wavelength and PZT 5A acoustic transducer. Stainless steel of 5mm thickness was used as a sample in experiment. Three line cracks of $50{\mu}m$ in each width and depth were made by using plasma on the surface of the sample. Also, each gap among their lines was $200{\mu}m$ and $300{\mu}m$ in width. In the scan range of $2.2mm\times2mm$ including surface defects, a good image of $50{\mu}m$ resolution had been shown when modulation frequency of CW laser was 100Hz.

  • PDF

Ultrasonic Testing Simulation in Austenitie Stainless Steel Weld by Ray Tracing Technique (선추적기법을 활용한 오스테나이트계 스텐레스강 용접부 초음파탐상 모의)

  • Lee, S.L.;Lim, H.T.;Park, C.S.;Kim, B.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.1
    • /
    • pp.310-317
    • /
    • 1995
  • Crack detection technique by ultrasonics in structures and components made of austenitic stainless steel often loses its reliability due to the material characteristics during inservice inspection of nuclear power plants, especially in the area of detection and sizing in centrifugally cast stainless steel pipings. In order to understand and overcome this problem, computer program for tracing the ultrasonic rays within material has been developed to simulate the process of defect detection within weld. The program simulates through transmission and reflection technique in crack detection of austenitic stainless steel as well as ultrasonic beam propagation through multiple media including stainless steel cladding interface.

  • PDF

The measurement of the internal strain of a concrete specimen using optical fiber interferometric sensors (광섬유 간섭계 센서를 이용한 콘크리트 구조물의 내부 스트레인 측정)

  • Lee, Kyung-Jin;Park, Jae-Hee;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.304-309
    • /
    • 2001
  • A Fiber optic strain sensor for the measurement of the internal strain of a concrete specimen was developed. This sensor was a 11 mm Fiber-optic Fabry-Perot interferometer attached inside a stainless steel pipe of 2 mm diameter. The fabricated strain sensors were embedded in a reinforced concrete structure of $100{\times}100{\times}500\;mm^3$ size and were measured the internal strain of a concrete structure when the external pressure was applied to the structure. For a field application, the strain sensors were attached on the bottom of a real bridge and dynamic loading test were executed. In the test, they showed good sensitivity as a deformation sensor and capability of remote monitoring.

  • PDF

Liquid Film Thickness Measurement by An Ultrasonic Pulse Echo Method (초음파 Pulse-echo 방법에 의한 액체막 두께 측정)

  • Jong Ryul Park;Jong-Ryul Park;Se Kyung Lee
    • Nuclear Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.25-33
    • /
    • 1985
  • The main purpose of this work is to investigate the effects of the wall thickness, the ultrasonic frequency, and the acoustic impedance of wall material on the liquid-film thickness measurement by an ultrasonic pulse echo method. A series of liquid-film thickness measurements in a horizontal air-water stratified system was performed employing a plate-type and a tube-type test sections. Measurements were repeated changing (1) the wall thickness of the test section and (2) the transducer frequency. Also, in an effort to improve the accuracy of the measurement and to exam me the effect of acoustic impedance of wall material on the measurement by an ultrasonic technique, two different stand-off rods, one made of stainless steel and the other polyacrylate, were used in the liquid-film thickness measurement. These experimental results are discussed and compared with the actual film thicknesses.

  • PDF