• Title/Summary/Keyword: 스테인리스강 와이어

Search Result 27, Processing Time 0.02 seconds

Effect of load on the wear and friction characteristics of a carbon fiber composites (탄소 섬유 복합재의 마찰 및 마모 특성에 미치는 하중 효과)

  • Koh, Sung-Wi;Yang, Byeong-Chun;Kim, Hyung-Jin;Kim, Jae-Dong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.4
    • /
    • pp.344-350
    • /
    • 2004
  • This is the study on dry sliding wear behavior of unidirectional carbon fiber reinforced epoxy matrix composite at ambient temperature. The wear rates and friction coefficients against the stainless steel counterpart specularly processed were experimentally determined and the resulting wear mechanisms were microscopically observed. Three principal sliding directions relative to the dominant fiber orientation in the composite wear selected. When sliding took place against smooth and hard counterpart, the highest were resistance and the lowest friction coefficient were observed in the antiparallel direction. When the velocity between the composite and the counterpart went up, the wear rate increased. The fiber destruction and cracking caused fiber bending on the contact surface, which was discovered to be dominant wear mechanism.

Evaluation of Creep-Fatigue Integrity for High Temperature Pressure Vessel in a Sodium Test Loop (소듐 시험루프 내 고온 압력용기의 크리프-피로 건전성 평가)

  • Lee, Hyeong-Yeon;Lee, Dong-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.831-836
    • /
    • 2014
  • In this study, high temperature integrity evaluation on a pressure vessel of the expansion tank operating at elevated temperature of $510^{\circ}C$ in the sodium test facility of the SEFLA(Sodium Thermal-hydraulic Experiment Loop for Finned-tube Sodium-to-Air heat exchanger) to be constructed at KAERI has been performed. Evaluations of creep-fatigue damage based on a full 3D finite element analyses were conducted for the expansion tank according to the recent elevated temperature design codes of ASME Section III Subsection NH and French RCC-MRx. It was shown that the expansion tank maintains its integrity under the intended creep-fatigue loads. Quantitative code comparisons were conducted for the pressure vessel of austenitic stainless steel 316L.

Evaluation on the sensitization degree for Inconel 600 by double-loop electrochemical potentiokinetic reactivation method (Double-loop electrochemical potentiokinetic reactivation 방법에 의한 Inconel 600의 예민화도 평가)

  • Jeong, Gwang-Hu;Lee, Jeong-Hyeong;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.110-110
    • /
    • 2018
  • 여러 니켈합금 중 인코넬 600은 원전 가압경수로(PWR)의 튜브 재료로 널리 사용되는 재료이다. 스테인리스강과 비교하여 우수한 내식성과 기계적 특성으로 인해 화학설비, 발전설비, 그리고 해양설비 등과 같은 여러 산업분야에서도 널리 사용되고 있다. 그러나 가압경수로용 증기 발생기의 튜브 재료와 같은 특수 환경에서 예민화에 따른 입계부식 및 입계응력부식 등의 문제가 흔히 보고되고 있다. 이러한 내구성 문제는 설비 및 장비의 수명, 내구성 그리고 안정성 등의 치명적인 영향을 미친다. 따라서 용접, 열처리, 그리고 가공과정에서 발생하는 Inconel 600의 예민화 및 입계부식에 관한 연구가 활발히 진행되고 있다. 그러나 100시간 이상 장시간 열화된 시편에 대한 예민화 연구는 전무한 실정이다. 본 연구에서는 장시간 열화된 Inconel 600의 예민화를 평가하기 위해 최대 1,000시간까지 열화를 실시하였으며, 이에 대한 평가방법으로 Double-Loop Electrochemical Potentiokinetic Reactivation(DL-EPR) 시험법을 적용하였다. 본 실험에서 사용된 인코넬 600의 화학성분(wt, %)은 0.01 C, 0.05 Si, 0.14 Mn, 15.3 Cr, 0.5 Cu, 0.015 S, 그리고 나머지는 Ni 이다. 예민화 평가를 위한 등온 열화는 전기열처리로를 이용하여, $550^{\circ}C$$650^{\circ}C$에서 최대 1000시간까지 실시하였다. 열화에 따른 미세조직 변화는 scanning electron microscope와 energy dispersive x-ray spectroscopy를 이용하여 실시하였다. DL-EPR 실험은 $25^{\circ}C$의 0.1M $H_2SO_4$ + 0.001M KSCN(potasium thiocyanate) 수용액 하에서 실시하였으며, 분극은 OCP로부터 600 mV(SSE vs.)까지 1.67mV/s 주사속도로 forward scan을 실시 후, 동일한 속도로 OCP까지 reverse scan을 실시하였다. Degree Of Sensitization(DOS)값은 anodic scan peak($I_a$) 값과 reverse scan peak($I_r$) 값의 비로 산출하였다. $$i.e.\;DOS=I_r/I_a{\times}100$$. 그 결과, 온도 변수에 따른 Inconel 600강의 예민화 거동은 서로 상이한 경향을 나타내었다. $550^{\circ}C$의 경우, 열화가 진행됨에 따라 DOS값은 급격하게 증가하는 경향을 나타냈다. 반면, $650^{\circ}C$에서는 일정시간 이후부터 Cr 확산 현상에 의한 탈 예민화 현상이 관찰되었다.

  • PDF

The reliability analysis of Acoustic Emission(AE) testing for crack detectivity by sensors and materials (AE(음향방출) 검사 시 센서 및 재료에 따른 균열 검출능에 대한 신뢰성 분석)

  • Nam, Jun-Young;Lee, Sang-Yun;Hwang, Woong-Gi;Lee, Bo-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.419-423
    • /
    • 2011
  • Unlike other non-destructive inspection method, AE Structural defects that are likely to grow in the operation status can be detected, and the advantage of being due to the continuous monitoring of large structures has been widely used to evaluate the stability. AE sensor used to detect sound wave that occurs between 20kHz to 20MHz. and Sound wave result may vary depending on sensor's sensitivity. In this paper, Tensile test conducted on STS 304 and SS400, and tries to detect the crack signal. In tensile test, specimens were conducted using different sensor sensitivity to the same tensile test condition. The crack signal parameters divided into 4 types of communities by conducting cluster analysis. It was demonstrated that crack signal of two sensor is not different by statistical analysis of null hypotheses. Based on the results, waveform of this tension test is crack signal.

  • PDF

Evaluation of Tensile Property of Austenitic Alloys Exposed to High-Temperature S-CO2 Environment (고온 S-CO2 환경에 노출된 오스테나이트계 합금의 인장특성 평가)

  • Kim, Hyunmyung;Lee, Ho Jung;Jang, Changheui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1415-1420
    • /
    • 2014
  • Super-critical $CO_2$ ($S-CO_2$) Brayton cycle has been considered to replace the current steam Rankine cycle in Sodium-cooled Fast Reactor (SFR) in order to improve the inherent safety and thermal efficiency. Several austenitic alloys are considered as the structural materials for high temperature $S-CO_2$ environment.. Microstructural change after long-term exposure to high temperature $S-CO_2$ environment could affect to the mechanical properties. In this study, candidate materials (austenitic stainless steels and Alloy 800HT) were exposed to $S-CO_2$ to assess oxidation resistance and the change in tensile properties. Loss of ductility was observed for some austenitic stainless steels even after 250 h exposure. The contribution of $S-CO_2$ environment on such changes was analyzed based on the characterization of the surface oxide and carburization of the materials in which 316H and 800H showed different oxidation behaviors.

Effect of Interlayer on TiN and CrN Thin Films of STS 420 Hybrid-Deposited by AlP and DC Magnetron Sputtering (AIP 와 스퍼터링으로 복합증착된 420 스테인리스강의 TiN과 CrN 박막에 미치는 중간층의 영향)

  • Choi, Woong-Sub;Kim, Hyun-Seung;Park, Burm-Su;Lee, Kyung-Ku;Lee, Doh-Jae;Lee, Kwang-Min
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.256-262
    • /
    • 2007
  • Effects of interlayer and the combination of different coating methods on the mechanical and corrosion behaviors of TiN and CrN coated on 420 stainless steel have been studied. STS 420 specimen were tempered at $300^{\circ}C$ for 1 hr in vacuum furnace. The TiN and CrN thin film with 2 ${\mu}m$ thickness were coated by arc ion plating and DC magnetron sputtering following the formation of interlayer for pure titanium and chromium with 0.2 ${\mu}m$ thickness. The microstructure and surface analysis of the specimen were conducted by using SEM, XRD and roughness tester. Mechanical properties such as hardness and adhesion also were examined. XRD patterns of TiN thin films showed that preferred TiN (111) orientation was observed. The peaks of CrN (111) and $Cr_2N$ (300) were only observed in CrN thin films deposited by arc ion plating. Both TiN and CrN deposited by arc ion plating had the higher adhesion and hardness compared to those formed by magnetron sputtering. The specimen of TiN and CrN on which interlayer deposited by magnetron sputtering and thin film deposited by arc ion plating had the highest adhesion with 22.2 N and 19.2 N. respectively. TiN and CrN samples shown the most noble corrosion potentials when the interlayers were deposited by using magnetron sputtering and the metal nitrides were deposited by using arc ion plating. The most noble corrosion potentials of TiN and CrN were found to be approximately -170 and -70 mV, respectively.

Correction of Single Thoracic Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation: Comparison of Stainless Steel to Titanium Alloy Instruments (척추경 나사못 고정술을 이용한 단일 흉추 청소년기 특발성 척추 측만증의 치료: 스테인리스강과 티타늄 합금 기기의 비교)

  • Kim, Sung-Soo;Lim, Dong-Ju;Kim, Jung-Hoon;Choi, Byung-Wan;Kim, Hwi-Young;Lee, Jun-Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.141-149
    • /
    • 2019
  • Purpose: To compare the results of two different instruments made of stainless steel and titanium alloy for correction of single thoracic adolescent idiopathic scoliosis (AIS) using pedicle screw instrumentation. Materials and Methods: A total of 141 patients with single thoracic AIS treated with pedicle screw instrumentation and selective thoracic fusion were retrospectively reviewed after a follow-up of 2 years. The patients had a main thoracic curve of 40° to 75° and were divided into two groups based on instrument materials; S group (stainless steel, n=90) and T group (titanium alloy, n=51). The diameter of the stainless steel rod used was 7.0 mm while that of the titanium alloy rod was 6.35 mm or 6.0 mm. Standing long-cassette radiographic measurements including various coronal and sagittal parameters for the preoperative, early postoperative and 2-year postoperative followup were analyzed. There were no significant differences in the preoperative curve characteristics between the two groups. Results: In the S group, the preoperative main thoracic curve of 51.3°±8.4° was improved to 19.0°±7.6° (63.1% correction) and the lumbar curve of 32.3°±8.4° spontaneously decreased to 12.7°±8.2° (62.9% correction) at 2 years postoperatively. In the T group, the preoperative main thoracic curve of 49.5°±8.4° and the lumbar curve of 30.3°±8.9° was improved to 18.8°±7.4° (62.2% correction) and 11.3°±5.4° (63.3% correction), respectively. The corrections of coronal curves were not statistically different between the two groups (p>0.05). The thoracic kyphosis was changed from 16.8°±8.5° to 24.3°±6.1° in the S group and from 19.6°±11.2° to 26.6°±8.5° in the T group. There were no significant differences in the changes of sagittal curves, coronal and sagittal balances at the 2-year follow-up and the number of fused segments and used screws between the two groups (p>0.05). Conclusion: When conducting surgery for single thoracic AIS using pedicles screw instrumentation, two different instruments made of stainless steel and titanium alloy showed similar corrections for coronal and sagittal curves.