• 제목/요약/키워드: 스테레오 PIV

검색결과 31건 처리시간 0.021초

표준영상을 이용한 스테레오 PIV와 스테레오 PTV의 성능비교 (Performance Tests on Stereoscopic PIV and Stereoscopic PTV using Standard Images)

  • 도덕희;황태규;조용범;편용범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1772-1777
    • /
    • 2004
  • The performances of the newly constructed Stereoscopic PTV and Stereoscopic PIV which had been completed based on a 3D-PTV principle are tested using the Standard Images. Virtual images were produced for the benchmark tests of the constructed two Stereoscopic techniques. The arrangement of the two cameras was based on angular position. The calibration of cameras and the pair-matching of the three-dimensional velocity vectors were based on Genetic Algorithm based 3D-PTV technique. The Standard data of LES are on the impinged jet proposed by VSJ. It is shown that the results obtained by Stereoscopic PTV have better reliability than those by Stereoscopic PTV.

  • PDF

스테레오 PIV (Stereoscopic PIV)

  • 도덕희;이원제;조경래;편용범;김동혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.394-399
    • /
    • 2001
  • A new stereoscopic PIV is introduced. The system works with CCD cameras, stereoscopic photogrammetry, and a 3D-PTV principle. Virtual images are produced for the construction of a benchmark testing tool of PIV techniques. The arrangement of the two cameras is based on angular position. The calibration of cameras and the pair-matching of the three-dimensional velocity vectors are based on 3D-PTV technique.

  • PDF

스테레오 PTV와 스테레오 PIV에 의한 선박프로펠러 후류측정 (Measurements of a Ship's Propeller Wake with Stereoscopic-PIV and Stereoscopic-PTV)

  • 도덕희;황태규;이상준
    • 한국가시화정보학회지
    • /
    • 제5권2호
    • /
    • pp.26-32
    • /
    • 2007
  • Stereoscopic PTV and Stereoscopic-PIV measurements have been carried out for the studies of the wake of a ship's propeller. Stereoscopic photogrammetry based on a 3D-PTV principle was introduced using two high-definition cameras(1k x 1k, 30Hz). The arrangement of the two cameras was based on angular position. The pair-matching of the three-dimensional velocity vectors were based on Genetic Algorithm based 3D-PTV technique. The results obtained by both measurement systems have been compared at the advance ratio J=0.88(290 rpm, d=54 mm). Turbulent properties have also been compared each other at the same condition.

스테레오 PIV에 의한 원관내 선회유동중 실린더형 부유체 주위 유동 특성 해석 (Flow Analysis around a Floating Cylinder in a Swirl Flow with a Stereoscopic-PIV)

  • 도덕희;황태규;다나카 코지;타께이 마사
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2006
  • The flow characteristics around a floating cylinder in a swirling flow field in a vertical pipe with a length of 600mm and an inner diameter of 100mm is investigated by the use of the Stereoscopic-PIV system. The measurement system consists of two cameras, a Nd-Yag laser and a host computer. Optical sensors(LEDs) were used to detect the location of the floating cylinder and to activate the Stereoscopic-PIV system. A conditional sampling Stereoscopic-PIV system was developed in which the flow fields around the floating cylinder are measured at the events of the activations. It has been verified that the motion of the floating cylinder becomes stable when the azimuthal velocity component of the swirl flow is maintained at stable states.

  • PDF

스테레오PIV에 의한 원주후류 난류통계량 계측 (Measurement of Turbulent Properties of a Circular Cylinder with a New Stereoscopic PIV)

  • 도덕희;이원제;조용범;편용범;하승운
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.471-474
    • /
    • 2002
  • A new stereoscopic PIV has been constructed using two CCD cameras, stereoscopic photogrammetry, and 3D-PTV principle. The capability of the developed stereoscopic PIV was verified through a test on the Standard Images which are provided on the website of VSJ. The arrangement of the two cameras was based on angular position For the acquisition of 3D velocity vectors, 2D velocity vectors were obtained using the gray-level cross-correlation method from the two camera images and they were matched stereoscopically. The wake of a circular cylinder was measured and turbulent properties were presented.

  • PDF

공기부양 물체의 유동-구조 연동운동 해석을 위한 능동형 스테레오-PIV 시스템 (Adaptive Stereoscopic-PIV System for the Analyses of the Flow-Structure-Interactions (FSI) of Air-Lifted Bodies)

  • 도덕희;황태규;조효제
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.420-425
    • /
    • 2006
  • Measurements results of flow-structure-interactions (FSI) of an air-lifted body are introduced. An adaptive stereoscopic-PIV system has been constructed for the measurements of the air-lifted body. The measurement system consists of two cameras and optical sensors. The flow characteristics around a lifted cylinder body(length=60mmm, diameter =10mm, polystyrene) in the swirling flow field in a vertical pipe (length=600mm, inner diameter=) are investigated by the use of the constructed adaptive stereoscopic-PIV system. The images of the two cameras were used for the analysis of the flow fields around the floated cylinder body. The images of the cylinder body captured by the two cameras were used for the analyses of its motions. Four optical sensors (LED) were used for the detection of the postures of the freely-lifted cylinder body. The FSI analyses have been carried out to find the physical conditions at which the floating body is stabilized with its upright postures.

  • PDF

호모지니어스 좌표계를 이용한 3차원 스테레오 PIV 알고리듬의 개발 (Development of 3-D Stereo PIV by Homogeneous Coordinate System)

  • 김미영;최장운;남구만;이영호
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.736-743
    • /
    • 2003
  • A process of 3-D particle image velocimetry, called here, as '3-D stereo PIV' was developed for the measurement of an illuminated slied section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transfromation of the oblique-angled image to the right-angled image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system, removal of error vectors by a statistical method followed by a continuity equation criterior, and finally 3-D animation as the post processing. An experimental system was also used for the application of the proposed method. Three analog CCD cameras and an Argon-Ion Laser(300mW) for illumination were adopted to capture the wake flow behind a bluff obstacle.

3차원 스테레오 PIV 개발 (Development of 3-D Stereo PIV)

  • 김미영;최장운;남구만;이영호
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.19-22
    • /
    • 2002
  • A process of 3-D particle image velocimetry, called here, as '3-D stereo PIV' was developed for the measurement of a section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transfromation of oblique-angled image to transformed image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system and finally 3-D animation as the post processing. In principle, as two frame images only are necessary for the single instantaneous analysis of a section field of 3-D flow, more effective vectors are obtainable contrary to the previous multi-frame vector algorithm. An experimental system was also used for the application of the proposed method. Three analog CCD cameras and an Argon-Ion Laser(300mW) for illumination were adopted to capture the wake flow behind a bluff obstacle.

  • PDF

Stereoscopic PTV 기법의 개발과 성능비교 연구 (Development of Stereoscopic PTV Technique and Performance Tests)

  • 이상준;윤전환
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.215-221
    • /
    • 2006
  • A stereoscopic particle tracking velocimetry (SPTV) technique based on the 2-frame hybrid particle tracking velocimetry (PTV) method was developed. The expansion of 2D PTV to SPTV is facilitated by the fact that the PTV method tracks individual particle centroids. To evaluate the performance and measurement accuracy of the present SPTV technique, it was applied to flow images of rigid body translation and synthetic standard images of jet shear flow and impinging jet flow. The data processing routine and measurement uncertainty of the SPTV technique are compared with those of conventional stereoscopic particle image velecimet.y (SPBV). In addition, the centroid translation effect of 2D particle image velocimetry (PIV) is defined and its effect on SPIV measurements is discussed. Compared to the SPIV method, the SPTV technique has inherited merits of concise and precise velocity evaluation procedures and provides better spatial resolution and measurement accuracy.