• 제목/요약/키워드: 스터링 냉동기

검색결과 40건 처리시간 0.031초

회전압축기형 스털링 냉동기의 열환경 성능시험에 관한 연구 (A Study on Thermal Environmental Performance Test of the Rotary Compressor Stirling Cryocooler)

  • 박성제;홍용주;김효봉;김대웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1953-1958
    • /
    • 2007
  • This paper presents the results of a series of performance tests for the integral Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Integral Stirling cryocooler for thermal imaging system have matured to the stage of undergoing formal qualification test program. The thermal environmental test of the Stirling cryocooler is presented in this paper. We performed that low and high temperature keeping test from $-40^{\circ}C$ to $+71^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooldown time to 80K and steady state input power at 80K were determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooldown time to 80K of less than 5 minutes 24seconds for $71^{\circ}C$ ambient temperature with input power of 11W

  • PDF

스터링 냉동기의 선철압축기 운전특성에 관한 연구 (Study of the Linear Compressor Characteristics of The Stirring Refrigerator)

  • 홍용주;박성제;김효봉;고득용;김종학;유병건
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.49-54
    • /
    • 2001
  • The purpose of this study is to analyze the characteristics of the linear compressor for Stirling refrigerator. To ensure high performance and long life of the FPFD(Free Piston. Free Displacer) type Stirling refrigerator, the operating parameters of the linear compressor should be optimized. The experimental results show that the operating frequency of the linear compressor has significant effect on the input power characteristics. and that the compressor with higher charging pressure of working fluid has high pressure ratio. For the high performance of the linear compressor. compressor should be operated at the resonance frequency with respect to the given charging pressure.

  • PDF

스터링 냉동기의 선헝압축기 운전특성에 관한 수치해석적 연구 (Numerical Analysis of Performance of Linear Compressor for the Stilting Cryocooler)

  • 홍용주;박성제;김효봉;염한길;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.58-62
    • /
    • 2002
  • The purpose of this study is to analyze the charging gas effect on the resonance and performance characteristics of the linear compressor for small scale FPFD Stirling refrigerator. To ensure high performance of FPFD type Stirling refrigerator, the operating frequency of the refrigerator should be around the natural frequency of compressor. The gas spring effect which is induced from Pressure change in cylinder due to motion of pistons has significant effect on the natural frequency of the compressor. The numerical results show the linear compressor has high natural frequency when the charging pressure of working fluid is high and the stroke of compressor, current, input power and efficiency of compressor were shown with different operating conditions.

선형압축기형 스터링 냉동기의 운전특성에 관한 수치해석적 연구 (The Numerical Analysis of Performance of the Stirling Cryocooler)

  • 홍용주;박성제;김효봉;염한길
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.181-184
    • /
    • 2002
  • The purpose of this study is to analysis the charging gas effect on the resonance and performance characteristics of the linear compressor for small scale FPFD Stirling refrigerator. To ensure high performance of FPFD type Stirling refrigerator, the operating frequency of the refrigerator should be around the natural frequency of compressor. The gas spring effect which is induced from pressure change in cylinder due to motion of pistons has significant effect on the natural frequency of the compressor. The numerical results show the linear compressor has high natural frequency when the charging pressure of working fluid is high.

  • PDF

질소냉매 스터링 냉동기의 성능에 관한 실험적 연구 (Experimental Study on the Performance of the Stirling Cryocooler with Nitrogen Refrigerant)

  • 김효봉;박성제;홍용주;염한길;고득용;김양훈;박종호
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.67-70
    • /
    • 2002
  • The Stirling cryocooler with helium refrigerant has been widely used for the cooling of the infrared detector, and the alternatives of the helium in the Stirling cryocooler are nitrogen and hydrogen gas. In this study, the performance experiment of the small FPFD(Free Piston and Free Piston) type Stirling cooler and the moving coil type, dual acting linear compressor was performed when the nitrogen and helium is used for the working fluid The results show that the nitrogen refrigerant has small cooling capacity compared with the helium, but the performance characteristics of the linear compressor does not greatly changed.

  • PDF

스터링 극저온 냉동기의 운전주파수 의존성에 관한 연구 (Study of the Dependency on Operating Frequency of the Stirling Cryocooler)

  • 홍용주;박성제;고득용;김효봉;김양훈;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stilting cryocooler for the cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, the dynamic characteristics of the displacer in the expansion space of the Stirling cooler was investigated by experiment. The experimental results show that the Stirling cryocooler has maximum cooling capacity at the certain relation between operating frequency and natural frequency of the displacer and the operating frequency of the Stirling crycooler should be determined by natural frequency of the linear compressor and displacer.

  • PDF

작동주파수에 따른 스터링 극저온 냉동기의 특성에 관한 연구 (Study of Stirling Cryocooler Performance with Different Operating Frequency)

  • 박성제;홍용주;고득용;김효봉;오군섭;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.159-162
    • /
    • 2001
  • A Stirling cryocooler is relatively compact, reliable, commercially available, and uses helium as a working fluid. The FPFD stirling cryocooler consists of two compressor pistons driven by linear motors which makes pressure waves and a pneumatically driven displacer piston with regenerator. It is the most suitable design for a mechanical cryocooler utilized in night vision environment. In order to get optimum operating frequency, natural frequency of piston and displacer, optimum phase angle between piston and displacer, cooling capacity, performance tests of the Stirling cryocooler by the frequency characteristics were performed.

  • PDF

작동주파수와 연결관 길이 변화가 스터링 냉동기의 성능에 미치는 영향 (The effect of the operating frequency and the length of the split tube on the performance for the Stirling cryocooler)

  • 김효봉;박성제;홍용주;고득용;김종학;유병건;박종호
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.55-61
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at korea Institute of Machinery & Materials. The FPFD Stirling cryocooler consists of two compressor pistons driven by linear motors which make pressure waves and a pneumatically driven displacer piston with regenerator. It is the most suitable design for a mechanical cryocooler utilized in night vision environment In this study, performance test of the Stirling cryocooler with different length of the split tube and operating frequency were performed to get characteristics of the cryocooler.

  • PDF

충전압력 및 작동주파수 특성 연구에 의한 스터링 냉동기 개발 (The effect of the charging pressure and operating frequency in the Stirling Cryocooler)

  • 박성제;홍용주;김효봉;고득용;김양훈;유병건;이기백
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.62-68
    • /
    • 2001
  • This paper presents manufacturing process and test results in the optimum pressure and operating frequency for the free piston free displacer(FPFD) Stirling cryocooler designed and manufactured by Korea Institute of Machinery &Materials (KIMM). FPFD Stirling cryocooler is currently under development uses opposed linear motors to drive opposed pistons . The performance of FPFD Stirling cryocooler is evaluated as a function fo charging pressure and operating frequency. In general as the operating frequency of the compressor is increaed but natural frequency of the displacer is almost constant. The prototype has achieved no load temperature of 49K and cooling capacity of 0.5W at 7.2K.

  • PDF