Study on the energy savings in the mobile communication repeater using a power factor correction circuit (역률보상회로를 이용한 이동통신 중계기의 에너지 절감에 관한 연구)

  • Lim, Byoung-Chul;Yoon, Wonsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1854-1860
    • /
    • 2014
  • In this paper, the energy saving on mobile communication repeater is studied. DB(Dual Band) small repeater, which is currently used in the field for indoor coverage, is adopted as a test unit. For reducing the power consumption, PFC (Power Factor Correction) is included on SMPS (Switching Mode Power Supply) of the DB small repeater. The test results show that approximately 38.9% of the power consumption is reduced comparing with the repeater without PFC. It means that approximately 230.43kWh per unit can be saved annually.

Design of Modular DC / DC Converter with Phase-Shifting Topology (위상천이 방식의 모듈형 DC/DC 컨버터 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • This paper is concerned with a system design that enables a the plurality of switching mode power supplies to be supplied with larger power through a parallel connection. For this purpose, a shunt resistor is placed in series at the output of the constant voltage regulator and the output voltage is sensed and controlled using an arduino. In this paper, two constant-voltage regulators were used for the experiment, but it is possible to generalize for more boards. By using the method that controls the system, the sum of the currents delivered by the two systems to the load was found to be 96% of the current drawn from each board. In case of efficiency, 92.4% efficiency is achieved in the unit board and the efficiency in parallel connection is about 90%.

Fault Prognostics of a SMPS based on PCA-SVM (PCA-SVM 기반의 SMPS 고장예지에 관한 연구)

  • Yoo, Yeon-Su;Kim, Dong-Hyeon;Kim, Seol;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.9
    • /
    • pp.47-52
    • /
    • 2020
  • With the 4th industrial revolution, condition monitoring using machine learning techniques has become popular among researchers. An overload due to complex operations causes several irregularities in MOSFETs. This study investigated the acquired voltage to analyze the overcurrent effects on MOSFETs using a failure mode effect analysis (FMEA). The results indicated that the voltage pattern changes greatly when the current is beyond the threshold value. Several features were extracted from the collected voltage signals that indicate the health state of a switched-mode power supply (SMPS). Then, the data were reduced to a smaller sample space by using a principal component analysis (PCA). A robust machine learning algorithm, the support vector machine (SVM), was used to classify different health states of an SMPS, and the classification results are presented for different parameters. An SVM approach assisted by a PCA algorithm provides a strong fault diagnosis framework for an SMPS.

The Ground Impedance Influence on Neutral Harmonic Currents (접지 임피던스가 중성선 고조파 전류에 미치는 영향)

  • Kim, Kyung-Chul;Paik, Seung-Hyun;Lee, Il-Moo;Kim, Jong-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.120-127
    • /
    • 2004
  • With the proliferation of nonlinear loads such as switching mode power supplies, high neurtral harmonic currents in three-phase four-wire distribution system have been observed. It has been known that the grounded impedance has an effect on the neutral current of a system which operates with harmonics present since the neutral conductor is grounded. On-site measurements of harmonic currents and voltages were made and the corresponding equivalent circuit was developed. The circuit model under study was simulated numerically and graphically through the use of the software MATLAB. Simulation results verifying the relationship between the neutral harmonic current and ground impedance are presented.

A Study on the Series Resonant Filler Application and Evaluation for Personal Computer Loads (컴퓨터부하의 직렬 동조필터 적용 및 평가에 관한 연구)

  • 김경철;강윤모;이일무;송영주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.40-48
    • /
    • 2003
  • Computer loads can be found in all of modem society. The switching mode power supplies used in personal computers are major sources of harmonic currents. Harmonic currents can cause lots of harmonic problems such as voltage waveform distortion, excessive neutral currents, errors in measurements, and disruption in computer performance. The purpose of this paper is to give an equivalent circuit modeling methodology for the harmonic currents generated by single-phase personal computer loads and to evaluate a commercially available series resonant filter for the harmonic currents compensation based on the IEEE 519-1992 and IEC1000-3-2 standards for limiting harmonic distortion.

A Study on the Harmonics and Voltage Sags Effect by the Series Resonant Filter Application for Personal Computer Loads (개인용 컴퓨터 부하의 직렬동조필터 적용에 의한 고조파 및 순간전압강하 영향에 관한 연구)

  • Seo, Beom-Gwan;Kim, Kyung-Chul;Lee, Il-Moo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.36-41
    • /
    • 2006
  • Computer Loads can be found in all of modern society. The switching mode power supplies used in personal computers are major sources of harmonic currents. Harmonic currents can cause lots of harmonic problems such as disruption in computer performance. A series resonant filter is very effective in harmonic reduction for personal computer loads. Voltage sags are short duration reductions in rms voltage. The main causes of voltage sags at faults, motor starting, and transformer energizing. Personal computers are another example of devices sensitive to voltage sags. A serious voltage sag at the terminals way lead mis-operation of the equipment. This paper presents an in depth analysis to evaluate the effect of harmonics reduction based on the IEC 61000-3-2 and the effect of voltage sag using ITI curve by applying a series resonant filter for personal computer loads.

A Comparative Study on Power System Harmonics for Offshore Plants (해양플랜트 전력시스템의 고조파 비교분석에 관한 연구)

  • Kim, Deok-Ki;Lee, Won-Ju;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.900-905
    • /
    • 2016
  • The field of power system harmonics has been receiving a great deal of attention recently. This is primarily due to the fact that non-linear (or harmonic-producing) loads comprise an ever-increasing portion of what is handled at a typical industrial plant. The incidence rate of harmonic-related problems is low, but awareness of harmonic issues can still help increase offshore power plant system reliability. On the rare occasion that harmonics become a problem, this is either due to the magnitude of harmonics produced or power system resonance. This harmonic study used an electrical configuration for the offloading scenario of a Floating LNG (FLNG) unit, considering power load. This electrical network configuration is visible in the electrical network load flow study part of the project. This study has been carried out to evaluate the performance of an electric power system, focusing on the harmonic efficiency of an electrically driven motor system to ensure offshore plant safety. In addition, the design part of this study analyzed the electric power system of an FLNG unit to improve the safety of operation and maintenance.