• Title/Summary/Keyword: 쉬스

Search Result 53, Processing Time 0.023 seconds

Development of a Circuit Model for the Dynamic Plasma Load in a PSII Pulse System (PSII 펄스 시스템의 동적 플라즈마 부하 회로 모델 개발)

  • Chung, K.J.;Choe, J.M.;Hwang, H.D.;Kim, G.H.;Ko, K.C.;Hwang, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.246-258
    • /
    • 2006
  • A circuit model has been developed to analyze characteristics of the PSII(plasma source ion implantation) pulse system with dynamic plasma load. The plasma sheath in front of the immersed planar target biased with a negative-high voltage pulse is assumed to be governed by the dynamic Child-Langmuir sheath model. Target current is self-consistently varied with the applied voltage by using the voltage-controlled current source in the circuit model. Circuit simulations are conducted with Pspice circuit simulator, and simulated pulse currents and voltages on the target are compared and confirmed with experimental results for various voltage pulses and plasma conditions.

Seismic Performance of Hollow Rectangular Precast Segmental Piers (프리캐스트 중공 사각형 철근콘크리트 교각의 내진성능)

  • Lee, Jae-Hoon;Park, Dong-Kyu;Choi, Jin-Ho;Shin, Sung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.705-714
    • /
    • 2012
  • Precast reinforced concrete bridge columns with hollow rectangular section were tested under cyclic lateral load with constant axial force to investigate its seismic performance. After all the precast column segments were erected, longitudinal reinforcement was inserted in the sheath prefabricated in the segments, which were then mortar grouted. Main variables of the test series were column aspect ratio, longitudinal reinforcement ratio, amount of lateral reinforcement, and location of segment joints. The aspect ratios were 4.5 and 2.5, and the longitudinal steel ratios were 1.15% and 3.07%. The amount of lateral reinforcement were 95%, 55%, 50%, and 27% of the minimum amount for full ductility design requirements in the Korean Bridge Design Code. The locations of segment joints in plastic hinge region were 0.5 and 1.0 times of the section depth from the bottom column end. The test results of cracking and failure mode, axial-flexural strength, lateral load-displacement relationship, and displacement ductility are presented. Then, safety of the ductility demand based seismic design in the Korean Bridge Design Code is discussed. The column specimens showed larger ductility than expected, because buckling of longitudinal reinforcing bar was prevented due to confinement developed not only by transverse steel but also by sheath and infilling mortar.

Control of size uniformity of Cu nanoparticle array produced by plasma-induced dewetting

  • Gwon, Sun-Ho;Choe, Han-Ju;Lee, Jeong-Jung
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.205-205
    • /
    • 2013
  • 플라즈마 밀도, 전자 온도, 쉬스 전압이 플라즈마 디웨팅으로 나노 분말 어레이를 제작할 때에 끼치는 영향을 연구하였다. 플라즈마 변수를 조절하여 기판에 입사하는 이온 충돌 에너지가 높은 조건에서는 디웨팅 시에 홀이 상대적으로 많이 생성이 되어 균일한 구리 나노 분말이 생성되었고, 반대의 경우에는 디웨팅 시 홀이 적게 생성되어 크고 작은 나노분말이 혼재해 있는 불균일한 구리 나노 분말 어레이가 형성되었다. 따라서 이온 충돌 에너지를 조절하면 구리 나노 분말의 균일도를 조절할 수 있다.

  • PDF

Analysis of Collisional Sheath in an Argon dc Discharge (아르곤 직류방전의 충돌쉬스 구조해석)

  • Choi, Young-Wook;Lee, Hae-June
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1647-1649
    • /
    • 2003
  • The electric fields of the sheath region in an argon do discharge were measured using a laser optogalvanic spectroscopy in a pressure range from 0.88 to 10 Torr, where collisions are significant in the sheath region. The sheath width is estimated as the position where the electric field becomes zero, and the pressure dependence of the measured sheath width was obtained to be $(pressure)^{-1/3}$. The measured electric fields agree well with one-dimensional simulation results but are slightly different from collisional sheath theory in the mobility limited region.

  • PDF

Numerical modeling of ICP with pulsed dc bias using CFD-ACE+ (CFD-ACE+를 이용한 ICP + pulsed dc bias system의 수치 모델링)

  • Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.127-127
    • /
    • 2009
  • 고밀도 유도 결합 플라즈마와 함께 -1 kV의 높은 펄스 직류 바이어스를 이용한 플라즈마 공정 장치를 CFD-ACE+를 이용하여 시변 모델로 해석하였다. 수 kHz의 낮은 펄스주파수와 $5{\mu}s$의 빠른 펄스 상승 시간의 효과에 의한 플라즈마 특성을 모사한 결과 전자 온도의 상승과 그에 의한 플라즈마 가열은 펄스 상승 시간 보다 수 ${\mu}s$늦게 발생하였으며 쉬스의 팽창은 Ar 10 mTorr에서 약 20 mm정도이며 계산된 전자 온도는 최고 20 eV에 이른다.

  • PDF

Experimental investigation on the dependence of the difference between plasma potential and floating potential on plasma density in cylindrical Langmuir probes (원통형 량뮤어 프로브에서의 플라즈마 전위와 부유 전위의 플라즈마 밀도 의존성 연구)

  • Chung, Chin-Wook;Lee, Won-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1967-1968
    • /
    • 2004
  • 최근 F. F. Chen 에 의하면 [F.F. Chen and D. Arnush, Phys. Plasmas, 8, 5051(2001)], 원통형 량뮤어 탐침의 경우 플라즈마 전위와 부유 전위의 차(${\triangle}V_{pf}$) 가 상수가 아니며 플라즈마 밀도에 따라 달라지고 밀도가 아주 높은 경우 즉 쉬스가 탐침의 반경보다 아주 얇은 경우에는 ${\triangle}V_{pf}$ 는 평면 탐침과 같이 상수가 된다는 것을 이론적으로 보였다. 이에 본 연구에서는 아르곤 유도 결합 플라즈마에서 원통형 량뮤어 탐침을 사용하여 F. F. Chen의 이론적인 결과를 실험으로 검증하였으며 F.F. Chen 의 이론적인 결과와 잘 일치하였다.

  • PDF

Vacuum / Plasma Lab Cart Design (진공 / 플라즈마 실험 카트 설계)

  • Gang, Chung-Hyeon;Gang, Dae-Hyeon;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.187-187
    • /
    • 2016
  • 진공 압력에 따른 플라즈마 발생의 관계, 전압에 따른 방전 밝기, gas와 방전 전극에 따른 플라즈마 색의 변화 등 실험을 통하여 학부생들에게 진공 시스템과 플라즈마의 이해도를 높이기 위해 Geissler tube cart를 제작하였다. Pump는 TMP station (PFEIFFER Vacuum Hi Cube ECO 80)을 사용하였으며 reducer를 이용하여 CF-4.5"에서 CF-2.75" adaptor를 설치, gate valve를 연결하여 진공도를 조절 할 수 있게 하였으며, 5-way를 이용하여 왼쪽은 gas line, 정면 view port, 상단 geissler tube, 후면 compact full range gauge를 설치하였고, cart 제작 결과를 Fig. 1에 나타내었다. Geissler tube의 수치모델은 Fig. 2에 나타내었다. 저진공(<10-3 Torr) 영역부터 고진공(<10-4 Torr) 영역까지 진공도에 따른 방전을 관찰 할 수 있으며, 표면과 플라즈마 사이의 전위 변화에 따른 쉬스(sheath) 관찰, trans 와 slidacs를 이용하여 전압 조정이 가능하기 때문에 전압에 따른 방전 관찰과 gas line을 통한 gas 주입에 따른 색의 변화를 관찰이 가능하도록 설계하였다.

  • PDF

Analysis on the Effects of the Induced Noise Voltage with the Grounded or Non-grounded Cable Sheath in the Power Inducting Situation (전력 유도 발생 시 케이블 쉬스 접지 여부에 따른 유도 잡음 전압 영향 분석)

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.285-288
    • /
    • 2007
  • This article presents the change characteristics of induced noise whether the sheath layer of the cable is grounded or not. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. The sheath ground is basicaly predicted to have the effects of alleviation on the power influence. But practically the effects may not happen in the case of common cable's sheath layer. Rather there are cases that the ground of sheath affects so that the noise level could increase. So we need to scrutinize the effects of the sheath gorund in the measures for the protection against electromagnetic induction by powerline or traction line system. And the evaluation of using the designated shielding purpose cable is needed.

  • PDF