• Title/Summary/Keyword: 숫자시표

Search Result 5, Processing Time 0.024 seconds

A Study of The Refraction at Video Display Terminal (VDT를 이용한 굴절검사에 대한 연구)

  • Lee, Hak Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.49-53
    • /
    • 2000
  • Comparing to an Image test chart which printed from computer. Hahn's standard test chart and Chart project test chart propose to make the program of an image test chart in computer. Test type of the test chart should be programed by difference size which was examined Hangul program of Hangul & Computer Co. An image test of visual acuity most decreased among 3 kinds of testing. Testing of Fixation disparity was same between Diplopia test and chart project test chart, so that. Design of test chart could be programed diverse by Hangul program of Hangul & Computer Co.

  • PDF

The Effects of the Relative Legibility of Optotypes on Corrected Visual Acuity (시표의 유형에 따른 상대가독성이 교정시력에 미치는 영향)

  • Ha, Na-Ri;Choi, Jang-Ho;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.177-186
    • /
    • 2015
  • Purpose: The Purpose of this study is to investigate if the relative legibility of optotypes affects the corrected visual acuity in visual acuity test. Methods: After measuring the relative legibility of 'Landolt ring target', 'arabic number target', 'alphabet target' by showing as a single-letter-target in 24 subjects without specific ocular diseases and ocular surgery experience, the relative legibility of 0.8, 1.0, 1.25 row of vision according to type of target in 7 types of chart were compared. After then we compared by measuring the corrected visual acuity according to type of target by using binocular MPMVA test (#7A) in 60 myopic subjects. Results: In 3 types of target the worst relative legibility target was 'Landolt ring target' with legible distance of $98.97{\pm}4.57cm$ and the best relative legibility target was 'alphabet target' with legible distance of $108.42{\pm}3.46cm$. There was no difference of the relative legibility according to type of chart or visual acuity level in the row of vision if other conditions are the same. In 1.0 and 1.25 row of vision the difference of relative legibility according to type of target was shown the statistically significant difference between 'Landolt ring target' and 'alphabet target' as $-0.07{\pm}0.06$ (p=0.02) and $-0.06{\pm}0.06$ (p=0.04) respectively. In myopia the difference of corrected visual acuity according to type of target was statistically significant difference between 'Landolt ring target' and 'arabic number target' as $-0.04{\pm}0.02$ (p=0.02) and it was especially remarkable in the low myopia. Conclusions: Measuring visual acuity with different optotypes could cause the errors in best vision measurement value because there was difference of the relative legibility according to type of target even though visual acuity level is same in the row of vision.

A Study of the Relationship between Visual Charts and Illumination (시표와 조명 사이의 상호관계에 대한 연구)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.91-96
    • /
    • 1999
  • This study involves the research about relationship between visual charts and illumination. The subjects were both males and females in their teens and twenties. The examination instrument used was a B-VAT II BVS(Mentol) which was produced in the USA, and the illumination used was a low illumination of 100LUX and a high illumination of 1500LUX in the clinical examination room. The results were as follows: 1. Different types of illumination resulted in similar values of visual acuity. 2. In the male teen subjects, the Snellen visual acuity was better than the numerical visual acuity when using low illumination. But the Landolt visual acuity presented similar results when using both low and high illumination. 3. In male subjects in their twenties, the Numerical visual acuity was better than the Landolt and Snellen visual acuity under low illumination. 4. In the female teen subjects, The Snellen visual acuity was better than the Landolt and Numerical visual acuity under low illumination. 5. In the female subjects in their twenties, The Snellen, Landolt and numerical visual acuities were high under low illumination. 6. Different types of illumination resulted in 0.3 or 0.4 variation of visual acuity. 7. The males and females was similar to the visual acuity.

  • PDF

A study on the accuracy of optotypes test chart (자동 시력표 정확도에 관한 연구)

  • Song, Kyung-Sek;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.111-118
    • /
    • 2005
  • The optotypes widely used as a necessity in the course of optometry are the world authorized versions which contain items such as the Landolt's rings, Snellen's chart and also Arabian numbers, Korean letters, Pictures and so on. In Korea, the Hahn-chun-suk test chart has been In use generally alolng with Chung-san test chart and Jin-yong-han test chart also in use on the wall. But these sort of test charts hung on the wall have some problems such as the difference in test results owing to the rate of illumination and so a more accurate method is required. To solve the problem of inaccuracy in optometry, the projected type of charts with digital instrument such as the beam projector has been developed lately. This chart projector with consistent high resolution and the ability to provide various charts can help eye examiner perform effective examination and thus is looked positively upon as the automated total optometry system. So in this study our purpose is to examine the accuracy of the projected chart. It was done by comparing it with the frequently used test chart. The results of experiment are as follow. When the projected chart was used, cases that subject read charts one step higher were 10%, two step higher 2% than perfectly corrected vision. When Han-chun-suk test chart was used, cases that subject read charts one step higher were 12%, and two step higher were 4%.

  • PDF

A Study on Comparision of the Quantity of Phoria as Way to Separation of Binocular Fusion (양안융합의 분리 시간에 따른 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.331-337
    • /
    • 2014
  • Purpose: This is a comparative experimental study on the amount of phoria by the removal time of binocular fusion. In this study, three tests were used for phoria test like Howell test, Thorington test and developed 3D polarizing test. Methods: In this study, it was considered the removal time of binocular fusion for measuring phoria. The three methods were used for measuring quantity of phoria: Howell test, Thorington test and developed 3D Polarizing test. The measurements progressed quickly to avoid eye-strain. So we designed the test charts for marking 3D display modules and the apparatus inserted lenses, like Maddox lens and prism, which are compatible with three phoria tests. The phoria at the moment separation was measured when the binocular fusion was broken through the apparatus and the that at the stable separation was measured when activity of the separated two images like indicated box and figure on horizontal axis stopped. Results: There were statistically significant difference between quantity of phoria at moment separation and that at stable separation. Amount of phoria at moment separation was relatively larger than amount of that at stable separation. In result in exophoria, the quantity of phoria at moment separation was higher than that at stable separation, and in phoria measured by developed 3D polarizing test, it shows the similar results at two condition. Conclusions: For exophoria, the amount of phoria at moment separation of binocular fusion was relatively larger than that at stable separation. The amount of difference between phoria values at moment separation and that at stable separation was alike among three phoria tests. Usually in working, there is no distinction between moment separation and stable separation. But there were definitely the difference between two ways to separate binocular fusion. Therefore, it is need for writing on prescription test name for measuring phoria and condition of separation of binocular fusion.