• Title/Summary/Keyword: 순환 Loop

Search Result 180, Processing Time 0.026 seconds

A Study on Improvement of 2-Dim Filtering Efficiency for Image (2차원 영상 필터링 효율 향상을 위한 기술연구)

  • Jeon, Joon-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.99-110
    • /
    • 2005
  • These days, many image processing techniques have been studied for effective image compression. Among those, The 2D image filtering is widely used for 2D image processing. The 2D image filtering can be implemented by performing the 1D linear filter separately in the horizontal and vertical direction. Efficiency of image compression depends on what filtering method is used. Generally, circular convolution is widely used in 2D image filtering for image processing. However it doesn't consider correlations at the boundary region of image, therefore effective filtering can not be performed. To solve this problem. I proposed new convolution technique using loop convolution which satisfies the 'alias-free' and 'error-free' requirement in the reconstructed image. This method could provide more effective compression performance than former methods because it used highly-correlated data when performed at the boundary region. In this paper, Sub-band Coding(SBC) was adopted to analyze efficiency of proposed filtering technique, and the simulator developed by Java-based language was used to examine the performance of proposed method.

Heat Transfer Characteristics of Supercritical $CO_2$ in Helical Coil Gas Coolers on the Change of Coil Diameters (코일직경변화에 따른 헬리컬 코일형 가스냉각기내 초임계 이산화탄소의 냉각열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.44-48
    • /
    • 2007
  • The cooling heat transfer characteristics of supercritical $CO_2$ in a helical coil gas cooler on the change of coil diameters are experimentally investigated. The main components of the refrigerant loop are a receiver, a variable speed pump, a mass flow-meter, a pre-heater and a helical coil gas cooler (test section). The test sections are made of a copper tube which the inner diameter is 4.55 mm and the helical coil diameters are done of 26.75 mm and 41.35 mm. The mass fluxes of refrigerant are varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler are 7.5 to 10.0 (MPa). A gas cooler with helical coil diameter of 26.75 mm has larger heat transfer coefficient than that of 41.35 mm. Also, when compared with experimental data and published correlations avaliable, most of correlations are under-predicted, but Pitla published correlations avaliable, most of correlations are under-predicted, but Pitla et al.'s correlation shows a relatively good coincidence with the experimental data except the region of pseudo critical temperature.

  • PDF

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF

Experimental Study for Evaporation Heat Transfer and Pressure Drop of R-22 and R-407C in an Inner Diameter of 4.3 mm and 6.4 mm (내경 4.3 mm와 6.4 mm관내 R-22와 R-407C의 증발 열전달과 압력강하에 관한 실험연구)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.43-49
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in horizontal copper tubes were investigated experimentally. The main components of therefrigerant loop are a receiver, a compressor, a mass flow meter, a condenser and a double pipe type evaporator (test section). The test section consists of a smooth copper tube of 4.3 mm and 6.4 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300[kg/m^2s]$ and the saturation temperature of evaporator were 5 [$^{\circ}C$]. The evaporation heat transfer coefficients of R-22 and R-407C rise with the increase in mass flux and vapor quality. The evaporation heat transfer coefficient of R-22 for inner diameter tube of 4.3 mm and 6.4 mm is about $7.3{\sim}47.1%$ and $5.68{\sim}46.6%$ higher than that of R-407C, respectively.

  • PDF

Design of Multivariable 2-DOF PID for Electrical Power of Flow System by Neural Network Tuning Method (신경망 튜우닝에 의한 유량계통 동력 제어용 다변수 2-자유도 PID의 제어기 설계)

  • 김동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 1998
  • The fluid system such as, the quantity control of raw water, chemicals control in the purification, the waste water system as well as in the feed water or circulation system of the power plant and the ventilation system is controlled with the valve and moter pump. The system's performance and the energy saving of the fluid systems depend on control of method and delicacy. Until, PI controller use in these system but it cannot control delicately because of the coupling in the system loop. In this paper we configure a single flow system to the multi variable system and suggest the application of 2-DOF PID controller and the tuning methods by the neural network to the electrical power of the flow control system. the 2-DOF controller follows to a setpoint has a robustness against the disturbance in the results of simulation. Keywords Title, Intelligent control, Neuro control, Flow control, 2 - DOF control., 2 - DOF control.

  • PDF

Performance Evaluation and Economic Estimation of Ground Source Heat Pump Cooling and Heating System (지열 냉난방 시스템의 성능 및 경제성 평가)

  • Lim Hyo Jae;Song Yoon Seok;Kong Hyoung Jin;Park Seong Koo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.296-300
    • /
    • 2004
  • Performance evaluation and economic estimation were conducted on the water to water GSHP (Ground Source Heat Pump) installed in existing building. Ground heat exchanger was a closed vertical loop type and sized to be 5 boreholes and 100m depth per borehole. Operation efficiency of the system shows that, COP increased from 3.0 to 4.2 with entering water temperature in heating operation, however, COP decreased from 5.0 to 3.7 in cooling operation. Economic estimation was analyzed by LCC (Life Cycle Cost) method and it showed that GSHP could save 68% of cost compare to the conventional oil source. Thus, despite of the large amount of initial cost, GSHP has a economic advantage to the other energy sources.

From a Defecation Alert System to a Smart Bottle: Understanding Lean Startup Methodology from the Case of Startup "L" (배변알리미에서 스마트바틀 출시까지: 스타트업 L사 사례로 본 린 스타트업 실천방안)

  • Sunkyung Park;Ju-Young Park
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.18 no.5
    • /
    • pp.91-107
    • /
    • 2023
  • Lean startup is a concept that combines the words "lean," meaning an efficient way of running a business, and "startup," meaning a new business. It is often cited as a strategy for minimizing failure in early-stage businesses, especially in software-based startups. By scrutinizing the case of a startup L, this study suggests that lean startup methodology(LSM) can be useful for hardware and manufacturing companies and identifies ways for early startups to successfully implement LSM. To this end, the study explained the core of LSM including the concepts of hypothesis-driven approach, BML feedback loop, minimum viable product(MVP), and pivot. Five criteria to evaluate the successful implementation of LSM were derived from the core concepts and applied to evaluate the case of startup L . The early startup L pivoted its main business model from defecation alert system for patients with limited mobility to one for infants or toddlers, and finally to a smart bottle for infants. In developing the former two products, analyzed from LSM's perspective, company L neither established a specific customer value proposition for its startup idea and nor verified it through MVP experiment, thus failed to create a BML feedback loop. However, through two rounds of pivots, startup L discovered new target customers and customer needs, and was able to establish a successful business model by repeatedly experimenting with MVPs with minimal effort and time. In other words, Company L's case shows that it is essential to go through the customer-market validation stage at the beginning of the business, and that it should be done through an MVP method that does not waste the startup's time and resources. It also shows that it is necessary to abandon and pivot a product or service that customers do not want, even if it is technically superior and functionally complete. Lastly, the study proves that the lean startup methodology is not limited to the software industry, but can also be applied to technology-based hardware industry. The findings of this study can be used as guidelines and methodologies for early-stage companies to minimize failures and to accelerate the process of establishing a business model, scaling up, and going global.

  • PDF

Effect of Drainage Reusing Ratio on Growth and Yield of Summer-cultivated Paprika in Recycling Hydroponic Cultivation (순환식 수경재배에서 배액 재사용율이 여름작형 파프리카의 생육 및 수량에 미치는 영향)

  • Jang, Dong-cheol;Choi, Ki-Young;Kim, II-Seop
    • Journal of Bio-Environment Control
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • This experiment was conducted to analyze the effect of drainage reuse rate on the growth and fruiting of summer paprika in closed hydroponic cultivation. The experiment was carried out for 25 weeks from March to September 2015 with 0, 20, 30, 50% mixing ratio of waste nutrient solution using non - recycling hydroponic cultivation as a control. As a result, stem diameter of the test was different in the groups 1 and 2, but no difference showed as the group progressed more than 3 groups. L.A.I tended to decrease with increasing drainage mixing ratio. The number of nodes in the 50% reuse test group was 1.4 compared to the control group, but there was no significant difference. The number of harvested nodes was significantly different in the control group (11.1 nodes) and the 50% reuse test group (8.7 nodes), and the harvested nodes tended to decrease as the drainage was reused. The ratio of harvest was also the same as that of the harvesting node, and the control was the highest at 33.2% and the lowest at the 50% reuse test at 27.6%. Relative yields were reduced by 30%, 35% and 45% in the control group in the first group, and this tendency was also observed in the second and fourth groups. However, in the 3 and 5 groups, the production of 50% test group increased by 13% and 5%. The ratio of unmarketable fruit was increased 2%, 4%, 4%, and 7% in 0%, 20%, 30% and 50% reuse test, respectively. In conclusion, if the decrease in yield due to the decline in early growth is carefully managed, even if the imbalance of inorganic ions occurs after the mid-term growth, the growth of the crop will enter into a stable period and the re-use will not be worried about the growth and the yield decrease.

Age Dependent Behaviors of Composite Girders Subjected to Concrete Shrinkage and Creep (건조수축과 크리프에 의한 합성형 거더의 재령종속적 거동)

  • Ahn, Sung-Soo;Sung, Won-Jin;Kang, Byeong-Su;Lee, Yong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.109-116
    • /
    • 2006
  • An incremental approach to predict the time dependent flexural behavior of composite girder is presented in the framework of incremental finite element method. Age dependent nature of creep, shrinkage, and maturing of elastic modulus of concrete is prescribed in the incremental tangent description of constitutive relation derived based on the first order Taylor series expansion applying to the total from of stress-strain relation. The loop phenomenon in which age dependent nature of concrete causes stress redistribution and it causes creep in turn is taken into account in the formulation through the incremental representation of constitutive relation. The developed algorithm predicts the time dependent deflections of 4.8m long two span double composite box girder subjected to shrinkage, maturing of elastic modulus, and creep initially induced by self weight. Comparison shows a good agreement between the predicted and measured results.

Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System (항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구)

  • Kang, Hoon;Jung, Jongho;Jung, Minwoo;Chi, Yongnam;Yoo, Yongseon;Choi, Heeju;Byeon, Youngman;Kim, Youngjin;Oh, Kwangyoon;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.431-439
    • /
    • 2013
  • A cooling system is adopted to control the thermal load from the avionic equipments in an aircraft for stable operation. In this study, an avionic cooling system was designed and manufactured by adopting a vapor compression cycle with a closed-loop air-circulation system to investigate the operating characteristics of an alternative refrigerant. The performance characteristics of a cooling system adopting R236fa as an alternative refrigerant were experimentally determined by varying the refrigerant charging amount, expansion valve opening, and compressor rotation speed. The experimental results were analyzed and compared with those of a cooling system adopting R124 as a refrigerant. The possibility of the adoption of R236fa as an alternative refrigerant was verified, and design solutions were suggested to improve the system efficiency.