• Title/Summary/Keyword: 순환 Loop

Search Result 180, Processing Time 0.027 seconds

Examining causal relationships between regulation and national competitiveness using system dynamics method (규제와 국가경쟁력간의 인과관계)

  • Choi, Young-Chool
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.137-147
    • /
    • 2018
  • Up until now, Korea has been recognized as one of the most severe and strict countries in terms of social regulation. As a result of that, it is generally accepted that economic activities in private sector have been contracted to some extent, weakening national competitiveness. Under this background, this paper examines the complex relationships among factors affecting national competitiveness and regulation and also seeks to discover feedback loops associated with its relationship. The research result shows that reinforcing feedback and balancing feedback loops are found in the system concerned with national competitiveness and regulation. Accordingly, it implies that we need to pay our attention to the management of those loops in order to discover the optimal point striking the balance between regulation and deregulation in terms of national competitiveness. It also implies that we need to conduct sensitivity analysis to forecast the potential results which the scenarios will bring about.

Decomposition of Ethylene by Using Dielectric Barrier Discharge Plasma (유전체 배리어 방전 플라즈마를 이용한 에틸렌의 분해)

  • Jang, Doo Il;Lim, Tae Hun;Lee, Sang Baek;Mok, Young Sun;Park, Hoeman
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.608-613
    • /
    • 2012
  • Dielectric barrier discharge plasma reactor was applied to the removal of ethylene from a simulated storage facility ($1.0m^3$) of fruits and vegetables. The system operated in a closed-loop mode by feeding the contaminated gas to the plasma reactor and recirculating the treated gas back to the storage facility. The experiments were carried out with parameters such as discharge power, circulation flow rate, initial ethylene concentration and treatment time. The rate of ethylene decomposition was mainly controlled by the discharge power and the treatment time. With the other conditions kept constant, the ethylene decomposition rate in the presence of the manganese oxide ozone control catalyst installed downstream from the plasma reactor was lower than that in the absence of it. The suggests that unreacted ozone from the plasma reactor accumulated in the storage facility where it additionally decomposed ethylene. On the basis of an initial ethylene concentration of 50 ppm, the energy requirement for completing the decomposition was about 60 kJ.

Basic Design and Sensitivity Analysis of 3 MWth Chemical Looping Combustion System for LNG Combustion and Steam Generation (LNG 연소 및 스팀생산을 위한 3 MWth 급 매체순환연소 시스템의 기본설계 및 민감도 분석)

  • RYU, HO-JUNG;NAM, HYUNGSEOK;HWANG, BYUNG WOOK;KIM, HANA;WON, YOOSEOB;KIM, DAEWOOK;KIM, DONG-WON;LEE, GYU-HWA;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.374-387
    • /
    • 2021
  • Basic design of 3 MWth chemical looping combustion system for LNG combustion and steam generation was conducted based on the mass and energy balance and the previous reactivity test results of oxygen carrier particles. Process configuration including fast fluidized bed (air reactor), loop seal and bubbling fluidized bed (fuel reactor) was confirmed and their dimensions were determined by mass balance. Then, the external fluidized bed heat exchanger (FBHE) was adopted based on the energy balance to extract heat from the system. The optimum reactor design and operating condition was confirmed with sensitivity analysis by modifying system configuration based on the mass and energy balance.

Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile (병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가)

  • Park, Sangwoo;Kim, Byeongyeon;Sung, Chihun;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.361-375
    • /
    • 2015
  • An energy pile is one of the novel ground heat exchangers (GHEX's) that is a economical alternative to the conventional closed-loop vertical GHEX. The combined system of both a structural foundation and a GHEX contains a heat exchange pipe inside the pile foundation and allows a working fluid circulating through the pipe, inducing heat exchange with the ground formation. In this paper, a group of energy piles equipped with parallel U-type (5, 8 and 10 pairs) heat exchange pipes was constructed in a test-bed by fabricating in large-diameter cast-in-place concrete piles. In addition, a closed-loop vertical GHEX with 30m depth was constructed nearby to conduct in-situ thermal response tests (TRTs) and to compare with the thermal performance of the cast-in-place energy piles. A series of thermal performance tests was carried out with application of an artificial cooling and heating load to evaluate the heat exchange rate of energy piles. The applicability of cast-in-place energy piles was evaluated by comparing the relative heat exchange efficiency and heat exchange rate with preceding studies. Finally, it is concluded that the cast-in-place energy piles constructed in the test-bed demonstrate effective and stable thermal performance compared with the other types of GHEX.

On the Bacterivory of Ciliates in the Estuarine System of the Mankyung and Dongjin rivers. (만경.동진강 염하수에서 섬모충류에 의한 박테리아 섭식에 관하여)

  • SHIM, JAE HYUNG;PARK, SOO YOUNG;CHO, BYUNG CHEOL;YIH, WONHO
    • 한국해양학회지
    • /
    • v.30 no.5
    • /
    • pp.426-435
    • /
    • 1995
  • In order to assess the significance of ciliate grazing on bacterial population in carbon flow of the estuarine pelagic ecosystem of the Mankyung and Dongjin river (MD estuary), abundance and biomass of ciliates and grazing rate on bacteria of small (<40 um) ciliates were measured. Saplings were carried out four times from October 1993 to March 1995 in the estuarine system. Ciliates smaller than 40 um occupied more than 49.5% of total ciliates abundance. Clearance rate of small ciliates ranged from 18.0 to 16.3 nl cell/SUP -1/ h/SUP -1/. As bacterial abundance increased, ciliate's clearance rate decreased, suggesting that bacterial abundance effects on ciliate's grazing rate. Ciliate grazing rate was equal to 0.1 to 12.2% of bacterial productivity, and the ratio of ciliate ingestion over bacterial production increased exponentially with the increase of bacterial abundance (r$^2$=0.62, p$\leq$0.001). It seems that the effect of ciliate grazing on bacteria would be small in coastal waters and large in more eutrophic waters of high bacterial abundance. Carbon supplied by ciliate grazing on bacteria was avg. 3.1% of carbon amount required for the ciliate maximum productivity. Thus, the ecological role of ciliate in microbial loop was probably more important as a final consumer than as a direct consumer of bacteria.

  • PDF

In-situ Methane Enrichment System Coupled with External $CO_2$ Stripper in Mesophilic Anaerobic Digestion (중온혐기성소화조에서 외부 $CO_2$ Stripping을 이용한 In-situ 고순도 메탄회수 공정 개발)

  • Kang, Ho;Jeong, Ji-Hyun;Lim, Seon-Ae;Lee, Hye-Mi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.155-161
    • /
    • 2012
  • A simple in-situ methane enrichment system in mesophilic anaerobic digestion was developed to take advantage of the differing solubilities of $CO_2$ and methane. The methane enhancement systems consisted of low solids plug-flow maize digester coupled with a leachate recycle loop to an external $CO_2$ stripper. The effects of leachate recycle rate (LRR) and reactor alkalinity on the resulting offgas $CH_4$ contents, biogas productivity and TVS removal efficiency were quantitively evaluated. The results showed that offgas $CH_4$ contents of over 94% was achieved at 3 volume of leachate recycle per volume of reactor per day (3 v/v-d) and at the reactor alkalinity of 4 g/L as $CaCO_3$, as the optimum operating conditions. The TVS removal efficiency of the methane enhancement system was 79% which corresponds to 94% of the control reactor and the methane productivity appeared to be 0.71 v/v-d. Offgas methane contents correlated well with LRR. However excessively high LRR led to the decrease in TVS removal efficiency.

A Study on the NOx Reduction of Flue Gas Using Un-divided Electrolysis of Seawater (무격막식 해수 전기분해 방식을 통한 배연 탈질에 관한 연구)

  • Kim, Tae-Woo;Choi, Su-Jin;Kim, Jong-Hwa;Song, Ju-Yeong
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.825-829
    • /
    • 2012
  • In this study, we investigated NO oxidation characteristic that depends on available chlorine concentration and temperature of seawater which is treated by un-divided electrolysis. Reactant gas passed through bubbling reactors which is filled with electrolyzed water and then NO concentration change was analyzed. In the closed-loop electrolysis system, concentration of available chlorine increased with electrolysis time. The higher oxidation rate of NO to $NO_2$ was obtained with the higher concentration of available chlorine. Oxidation of NO was fast when temperature of electrolyzed water was high, in the case of same concentration of available chlorine.

Design of Ground-Coupled Heat Pump (GCHP) System and Analysis of Ground Source Temperature Variation for School Building (학교 건물용 지열 히트펌프 시스템 설계와 지중 순환수 온도 변화 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Ground-coupled heat pump (GCHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. Although some experimental and simulation works related to performance analysis of GCHP systems for commercial buildings have been done, relatively little has been reported on the performance evaluation of GCHP systems for school buildings. The purpose of this simulation study is to evaluate the performance of a hypothetical GCHP system for a school building in Seoul. We collected various data of building specifications and construction materials for the building and then modeled to calculate hourly building loads with SketchuUp and TRNSYS V17. In addition, we used GLD (Ground Loop Design) V2016, a GCHP system design and simulation software, to design the GCHP system for the building and to simulate temperature of circulating water in ground heat exchanger. The variation of entering source temperature (EST) into the system was calculated with different prediction time and then each result was compared. For 20 years of prediction time, EST for baseline design (Case A) based on the hourly simulation results were outranged from the design criteria.

A fundamental Study on the Manufacturing and Operating Characteristics of a Small Scale CPL Heat Pipe (소형 CPL 히트파이프의 제작 및 작동 특성에 관한 기초연구)

  • 안영길;유성열;임광빈;김철주
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.17-22
    • /
    • 2003
  • The present study was conducted to obtain the fundamental knowledge on the manufacturing and operating characteristics of a small scale CPL (Capillary Pumped Loop) heat pipe. CPL heat pipes are able to transfer heat effectively at any orientation in a gravitational field over long distances. An experimental model with an evaporator of a circular plate shape was designed and manufactured and its operating performances were tested. A Bronze powder sintered metal plate of 3 mm thick and $\Psi$ 50 mm was used as wick and ethanol was used as working fluid. An experimental apparatus was set up to ascertain the operating conditions oi CPL at different heat load and an surrounding temperature at the condenser was maintained about 13$^{\circ}C$.

Characteristic Analysis of a Small ALIP for the Developing of the Liquid Sodium (액체 소듐 순환 구동용 소형 환단면 선형유도전자펌프의 특성 분석)

  • Kim, Hee-Reyoung;Kim, Jong-Man;Nam, Ho-Yun;Hwang, Jong-Sun;Seo, Jang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.1-3
    • /
    • 1999
  • EM (ElectroMagnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). (In the present study, pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.

  • PDF