Background: In cardiac surgery, hypothermia is associated with a number of major disadvantage, including its detrimental effects on enzymatic function, energy generation and cellular integrity. Warm cardioplegia with normothermic cardiopulmonary bypass cause three times more incidence of permanent neurologic deficits than the cold crystalloid cardioplegia with hypothermic cardiopulmonary bypass. Interruptions or inadequate distribution of warm cardioplegia may induce anaerobic metabolism and warm ischemic injury. To avoid these problems, tepid blood cardioplegia was recently introduced. Material and Method: To evaluate whether continuous tepid blood cardioplegia is beneficial in clinical practice during valvular surgery, we studied two groups of patients matched by numbers and clinical characteristics. Warm group(37$^{\circ}C$) consisted of 18 patients who underwent valvular surgery with continuous warm blood cardioplegia. Tepid group(32$^{\circ}C$) consisted of 17 patients who underwent valvular surgery with continuous tepid blood cardioplegia. Result: Heartbeat in 100% of the patients receiving continuous warm blood cardioplegia and 88.2% of the patients receiving continuous tepid blood cardioplegia converted to normal sinus rhythm spontaneously after removal of the aortic cross clamp. There were no differences between these two groups in CPB time, ACC time, the amount of crystalloid cardioplegia used and peak level of potassium. During the operation, the total amount of urine output was more in the warm group than the tepid group(2372${\pm}$243 ml versus 1535${\pm}$130 ml, p<0.01). There were no differences between the two groups in troponin T level measured 1hr and 12hrs after the operation. Conclusion: Continuous tepid blood cardioplegia is as safe and effective as continuous warm blood cardioplegia undergoing cardiac valve surgery in myocardial protection.
Journal of the korean academy of Pediatric Dentistry
/
v.35
no.4
/
pp.619-627
/
2008
The objective of this study was to compare the microleakage of five adhesive systems in the enamel and dentin of permanent teeth. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 25 extracted human molar teeth. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM), Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL) and G-Bond (GB). The results were as follows: 1. At the enamel margins, PL showed the highest leakage value(0.85), and others showed values of SB(0.55), GB(0.50), SM(0.35) and SE(0.25) in decreasing order. There were statistically significant differences in PL vs. SM and PL vs. SE(p<0.05). 2. At the dentin margins, GB showed the highest leakage value(2.10), and others showed values of SE(1.45), PL(1.40), SB(1.05), SM(0.70) in decreasing order. There were statistically significant differences in GB vs. SB and GB vs. SM(p<0.05). 3. Dentin margins showed high dye penetration rate than enamel margins in all material tested groups and there were statistically significant differences for SE, PL and GB.
Journal of the Korean Institute of Landscape Architecture
/
v.45
no.4
/
pp.11-22
/
2017
A plaza represents the identity of a city, and that reveals a plaza's importance. Gwanghwamun Plaza and Seoul Plaza are two representative plazas where the citizens can freely express their opinions. Many major plazas in the center of Seoul were built under the Japanese occupation. Among these, the plaza of Joseon Bank has different characteristics than Gwanghwamun Plaza and Seoul Plaza. Even though this plaza was built in the center of the commercial, administrational, and cultural district during the Japanese colonial period, the research on this plaza has been limited. This study was conducted to verify the features of this plaza by analyzing its construction and transformation during the Japanese colonial period. The study's results outline how the plaza was constructed by the Japanese administration. The intention of the government is shown by the fact that it purchased land parcels and held a design competition. In the 1910s, the government purchased seven parcels of land during the expansion of roads as the place for the plaza. During the late 1930s, the government accepted a traffic circle to regulate the traffic and eliminate the conflict between crossing movements. In 1939, a fountain was built in the plaza's center, and its design was selected through a design competition. It was planned as a square, but gradually turned into a rotary. Furthermore, the plaza was a landmark and symbol of the power and modernity of Japan. As the main modal point of public transportation, the plaza became surrounded with largescale Western-style buildings, commercial advertising, and neon signs. The plaza became a place where people could experience the modern city. These spectacular displays showed that Japanese imperialism was perceived as a strange and peculiar landscape to the majority of Korean citizens. This study investigates the history and characteristics of the plaza, focusing on its beginning as well as the transformation of its form. As to the limitations of the study, it does not consider political and economic contexts within the transformation of Seoul and in relation to this plaza. Instead, that research remains for a future study.
The correlation and Empirical Orthogonal Function (EOF) analyses over the globe have been applied to intercompare lower-stratospheric (${\sim}$70hPa) temperature obtained from satellite data and two model reanalyses. The data is the19 years (1980-98) Microwave Sounding Unit (MSU) channel 4 (Ch4) brightness temperature, and the reanalyses are GCM (NCEP, 1980-97; GEOS, 1981-94) outputs. In MSU monthly climatological anomaly, the temperature substantially decreases by ${\sim}$21k in winter over southern polar regions, and its annual cycle over tropics is weak. In October the temperature and total ozone over the area south of Australia remarkably increase together. High correlations (r${\ge}$0.95) between MSU and reanalyses occur in most global areas, but they are lower (r${\sim}$O.75) over the 20-3ON latitudes, northern America and southern Andes mountains. The first mode of MSU and reanalyses for monthly-mean Ch4 temperature shows annual cycle, and the lower-stratospheric warming due to volcanic eruptions. The analyses near the Korean peninsula show that lower-stratospheric temperature, out of phase with that for troposphere, increases in winter and decreases in summer. In the first mode for anomaly over the tropical Pacific, MSU and reanalyses indicate lower-stratospheric warming due to volcanic eruptions. In the second mode MSU and GEOS present Quasi-Biennial Oscillation (QBO) while NCEP, El Ni${\tilde{n}}$o. Volcanic eruption and QBO have more impact on lower-stratospheric thermal state than El Ni${\tilde{n}}$o. The EOF over the tropical Atlantic is similar to that over the Pacific, except a negligible effect of El Ni${\tilde{n}}$o. This study suggests that intercomparison of satellite data with model reanalyses may estimate relative accuracy of both data.
Park, Kyung-Ae;Lee, Jae Yon;Lee, Eun-Young;Kim, Young Ho;Byun, Do-Seong
Journal of the Korean earth science society
/
v.41
no.5
/
pp.490-503
/
2020
Oceanic current and circulation have played an important role as regulators of the earth's energy distribution. The science and earth science textbooks for secondary schools based on the 2015 revised curriculum included a misconception of the seasonal variation of the North Korea Cold Current (NKCC) among the currents around the Korean Peninsula. To analyze this, the contents related to the NKCC were collected in the textbooks of five middle and six high schools, and a questionnaire survey was conducted on 30 middle school science teachers. The survey consisted of questions about whether the textbook mentions the NKCC and whether there is an error in the concept of the temporal variation of the NKCC, and the teachers' free opinions related to the NKCC were collected. The textbooks suggest that the NKCC is strongest in winter, which is not consistent with scientific findings so far. In fact, there is scientific evidence that the NKCC is the strongest in the summer. In this study, the causes and processes of misconceptions were investigated. According to an analysis of the survey, most teachers had an knowledge that the NKCC is stronger in winter. These errors began with a misconception of the terms, which teachers had imprinted on their memory as firm knowledge. These misconceptions originated from the knowledge that teachers themselves acquired from their secondary school years and have long been transferred back to teachers and students without revising the misconceptions of textbooks. This situation is expected to have a seriously recurrent structure that produces students' serious misconceptions in the future. Therefore, this study summarizes existing results on the seasonal variability of the NKCC and suggests the necessity for re-education to improve teachers' professionalism and to eliminate the misconceptions of teachers and students.
Journal of the korean academy of Pediatric Dentistry
/
v.34
no.2
/
pp.204-214
/
2007
The aim of this study was to investigate whether differences in surface treatment prior to repair influenced the seal of a resin fissure sealant placed on the occlusal surfaces of permanent molar teeth. One hundred and twenty extracted human molars were selected and a light curing sealant was placed on their occlusal surface following cleaning by prophylaxis and acid etching. The teeth were deliberately damaged, and then stored in artificial saliva for four weeks. Sixty teeth with the desired morphology of sealant failure were randomly divided into four groups where one group was treated with only etching agent, another by only air-abrasion, another by applying an etching agent followed by a bonding agent, and the last by air-abrasion followed by a bonding agent each. After sealant application, the samples were thermocycled and the degree of microleakage was determined. The results were as follows : 1. In the sealant/sealant interface group 2(0.22), 4(0.23) using air-abrasion showed a significantly lower microleakage score than group 1(0.38), 3(0.35) using an etching agent(p<0.05). There were no statistically significant differences(p>0.05) between groups 1, 2 and groups 3, 4. 2. In the sealant/tooth interface, group 3(0.20), 4(0.20) which used a bonding agent showed a significantly lower microleakage score than group 1(0.35), 2(0.40) (p<0.05). There were no statistically significant differences(p>0.05) between groups 1, 3 and groups 2, 4. 3. In SEM examination, while sealant surfaces treated with etching did not result in highly rough surfaces, those treated with air-abrasion did show rough surfaces.
Kim, Hyeong-Jin;Yang, Hye-Jin;Kim, Mi-Hwan;Ryu, Gi-Hyung;Jung, Ji-Youn
Journal of the Korean Society of Food Science and Nutrition
/
v.38
no.9
/
pp.1179-1186
/
2009
This study was carried out to investigate the effect of saengmaec-san on the level of blood glucose and serum components in streptozocin (STZ)-induced diabetic rats. The experimental groups were divided into normal group (normal), diabetic control group (Dia-control), 10% saengmaec-san (white ginseng) group (DA), 10% saengmaec-san (fermented white ginseng) group (DB), 10% saengmaec-san (fermented red ginseng) group (DC), 5% saengmaec-san (extruded and fermented white ginseng) group (DDL), 10% saengmaec-san (extruded and fermented white ginseng) group (DDH). The body weight after induction of diabetes was 85.4% in the Dia-control group compared with the normal group. But in the DA group, the body weight showed clear sign of recovery almost normal level after administration of saengmaec-san for two weeks. The food efficiency ratios (FER) were 5.94% in the normal group. But it was significantly decreased in the Dia-control group (0.58%). All the treatment groups showed increase of FER compared with the Dia-control group. The level of blood glucose was significantly increased in the STZ-induced diabetes groups but it was decreased in all the treatment groups after administration for 2 weeks. Serum creatinine level were significantly higher in the STZ-induced diabetes groups and after administration of saengmaeg-san for 2 weeks while the level of serum creatinine was decreased 33.3% in the DB group. After administration of saengmaec-san for two weeks, serum total cholesterol level were significantly lower in all treatment groups than the first day of the total cholesterol level. The level of serum triglyceride was increased in all the treatment groups compared with the first day of triglyceride level. The level of serum HDL-cholesterol, after STZ-induced diabetes, was decreased in all treatment groups but particularly in the DDL and DDH groups increased HDL-cholesterol level compared with the first day of the saengmaec-san administration. Compared with the beginning of experiment, Atherogenic index (AI) were significantly decreased in all treatment groups than the Dia-control group and showed clear sign of recovery almost normal level. These results suggested that the saengmaec-san could be developed as an antidiabetic agent.
Lim, Byung Sung;Sohn, Jang Won;Yang, Seok Chul;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
Tuberculosis and Respiratory Diseases
/
v.52
no.4
/
pp.395-404
/
2002
Background : Surfactant protein A (SP-A) is important for regulating surfactant secretion, synthesis and recycling. However, It's regulation in vivo is unclear. SP-A has important roles in regulating surfactant metabolism as well as determining its physical properties. Glucocorticoid accelerates the morphologic differentiation of epithelial cells into type II cells and increase the rate of phosphatidylcholine synthesis. Methods : The authors investigated the effects of glucocorticoid on the accumulation of mRNA encoding SP-A and SP-A protein content. Adult rats were given various doses of subcutaneous dexamethasone and sacrificed after 24 hours and one week. SP-A mRNA was measured using a filter hybridization method. The lung SP-A protein content was determined using a double sandwich ELISA assay with polyclonal antiserum raised in rabbits against purified rat SP-A. Results : 1) The accumulation of SP-A mRNA in the dexamethasone treated group 24 hours after 0.2 mg/kg dexamethasone treatment was increased 38.8% compared to the control group. 2) The accumulation of SP-A mRNA in the dexamethasone treated group 1 week after 2 mg/kg dexamethasone treatment was 49.7% higher than the control group(P<0.01). 3) The total lung SP-A level was not altered after 24 hours by the 0.2mg/kg treatment. The total lung SP-A content one week after 2mg/kg dexamethasone administration was 373.7% higher than the control group(P<0.005). Conclusion : Dexamethasone treatment results in an increase in the SP-A mRNA and SP-A protein levels, suggesting that the pretranslational events in vivo may in part contribute to this process.
This study was conducted to investigate the situation of ICT apply to plastic greenhouse, and the results be apply to design of new one. A CFD analysis were conducted to monitering the ventilation and energy saving of the single span greenhouse newly designed. The causes of delay to apply ICT to plastic greenhouse are the high cost for installation(24%), insufficiency of after services(19%), often disorder(16%), unskillful management of soft ware(15%), insufficient ICT efficiency(13%) and unsatisfying of income increase(12%). The parts of problem occurred in ICT plastic greenhouse are the structure, actuator, environmental control system and sensor(approximate 14%, respectively), remote control technique(13%), plant management technique(12%), energy saving technique(10%) and utilization of software(8%). In the condition of lateral window closed, the average wind speed changed to slow, but it was faster in the condition of leeward side window opened than in the condition of lee and winward side window opened. The air movement in the condition of lateral window closed occur by air moving fan not by out air. It is not affect the room temperature but effective the uniformity of room temperature. The average temperature of low height greenhouse was uniform than high height one. The average temperature in condition of 3rd curtain opened become same with outside temperature after 2 hours, but take more 5 hours in condition of 3rd curtain closed.
Lee, Eun Mo;Park, Sang Kyu;Kim, Gyoung Je;Lee, Bong Chun;Lee, Hee Chul;Yun, Yeo Uk;Park, Soo Bok;Choi, Jong Myoung
Journal of Bio-Environment Control
/
v.26
no.4
/
pp.361-367
/
2017
Production cost as well as environmental contamination can be reduced by reuse of drained nutrient solution in hydroponic. This research was conducted to obtain the information in changes in inorganic elements concentration of supplied and drained nutrient solution as well as of plant leaves. To achieve the objective, the samples of supplied and drained solution and cherry tomato leaf tissues were periodically collected and analyzed during the hydroponic cultivation. The electrical conductivity (EC) of supplied and drained nutrient solution in early growth stage of cherry tomato were measured as around $2.0dS{\cdot}m^{-1}$, but those values move up with the passage of time reaching to $2.0dS{\cdot}m^{-1}$ at flowering stage of 9th fruiting node. The pHs of drained solution in early growth stage were 6.4 to 6.7, however those showed a tendency to get lowered to 5.9 to 6.1 as time passed during the crop cultivation. The concentration differences of $NO_3-N$, P, K, Ca, and Mg between supplied and drained solution were not distinctive until flowering stages of 4th fruiting nodes, while those in drained solution moved up after the stage. The tissue N contents of leaves decrease gradually and those of K and Ca increased as crops grew. However, Tissue P and Mg contents were maintained similarly from transplant to end-crop. The above results would be used in correction of drained nutrient solution when element compositions are varied compared to supplied solution in hydroponic cultivation of tomatoes.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.