• Title/Summary/Keyword: 숙련도실험

Search Result 64, Processing Time 0.023 seconds

A literature review on clinical/ laboratory misfit evaluation on implant-prosthesis (임플란트와 상부보철물의 임상적/실험적 부적합 평가에 관한 문헌고찰)

  • Kim, Jong-Hoi;Cho, Woong-Rae;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.56 no.9
    • /
    • pp.462-478
    • /
    • 2018
  • The presence of implant-prosthesis misfits can cause various complications. It is very important to detect misfits to prevent such complications. There are various evaluation methods for misfit assessment including clinical methods and laboratory in vitro methods. The clinical misfit evaluation includes radiographic analysis, visual observation, probing, Sheffield test, evaluation with disclosing materials, and screw resistance test. The laboratory in vitro evaluation method includes indirect modelling evaluation and direct metrological visualization. Of the indirect modelling methods, photoelastic stress analysis, finite element analysis, strain gauge analysis, and microbial colonization analysis were reviewed. Of the direct metrological visualization, microscopic analysis, 3-D photogrammetric analysis, coordinate measuring analysis, and radiographic analysis were reviewed. In this review, the characteristics, advantages and disadvantages of each method were evaluated.

  • PDF

A Study of Practical and Optimized Mineral Quantification (실용적이고 최적화된 광물정량분석법 연구)

  • Son, Byeong-Kook;An, Gi-O
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.4
    • /
    • pp.227-239
    • /
    • 2021
  • A practical and effective method of X-ray powder diffraction analysis was investigated for quantitative analysis of the mineral content of natural samples. Sample mounting experiments were conducted to select the best randomly oriented powder sample mount. A comparative experiment was also made between a reference intensity ratio (RIR) method, which compares a single peak intensity with standard material, and the Rietveld method, which calculates a full X-ray diffraction pattern, to search for the effective method of mineral quantification. In addition, samples containing amorphous minerals were quantitatively analyzed by the Rietveld method and the efficiency was reviewed. As a result of the study, the optimal random orientation could be reached by the side mounting method. The Rietveld method using the full pattern of X-ray diffraction was more suitable for mineral quantitative analysis, rather than the RIR method using a specific peak. However, either method could depend on the analyst's experience in addition to analytical technique. Moreover, amorphous minerals can be quantitatively analyzed by the Rietveld method, and the analysis results make the geological analysis possible.

A Comparative Study on Quantifying Uncertainty of Vitamin A Determination in Infant Formula by HPLC (HPLC에 의한 조제분유 중 비타민 A 함량 분석의 측정불확도 비교산정)

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.152-159
    • /
    • 2008
  • The purpose of this study was to determine the accurate quantification of vitamin A in infant formula by comparing two different standard stock solutions as well as various sample weights using high performance liquid chromatography. The sources of uncertainty in measurement, such as sample weight, final smaple vloume, and the instrumental results, were identified and used as parameters to determine the combined standard uncertainty based on GUM(guide to the expression of uncertainty in measurement) and the Draft EURACHEM/CITAC Guide. The uncertainty components in measuring were identified as standard weight, purity, molecular weight, dilution of the standard solution, calibration curve, recovery, reproducibility, sample weight, and final sample volume. Each uncertainty component was evaluated for type A and type B and included to calculate the combined uncertainty. The analytical results and combined standard uncertainties of vitamin A according to the two different methods of stock solution preparation were 627 ${\pm}$ 33 ${\mu}$g R.E./100 g for 1,000 mg/L of stock solution, and 627 ${\pm}$ 49 ${\mu}$g R.E./100 g for 100 mg/L of stock solution. The analytical results and combined standard uncertainties of vitamin A according to the various sample weighs were 622 ${\pm}$ 48 ${\mu}$g R.E./100 g, 627 ${\pm}$ 33 ${\mu}$g R.E./100 g, and 491 ${\pm}$ 23 ${\mu}$g R.E./100 g for 1 g, 2 g, and 5 g of sampling, respectively. These data indicate that the preparation method of standard stock solution and the smaple amount were main sources of uncertainty in the analysis results for vitamin A. Preparing 1,000 mg/L of stock solution for standard material sampling rather than 100 mg, and sampling not more than 2 g of infant formula, would be effective for reducing differences in the results as well as uncertainty.

Designing a quality inspection system using Deep SVDD

  • Jungjun Kim;Sung-Chul Jee;Seungwoo Kim;Kwang-Woo Jeon;Jeon-Sung Kang;Hyun-Joon Chung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.11
    • /
    • pp.21-28
    • /
    • 2023
  • In manufacturing companies that focus on small-scale production of multiple product varieties, defective products are manually selected by workers rather than relying on automated inspection. Consequently, there is a higher risk of incorrect sorting due to variations in selection criteria based on the workers' experience and expertise, without consistent standards. Moreover, for non-standardized flexible objects with varying sizes and shapes, there can be even greater deviations in the selection criteria. To address these issues, this paper designs a quality inspection system using artificial intelligence-based unsupervised learning methods and conducts research by experimenting with accuracy using a dataset obtained from real manufacturing environments.

Improvement of computer keyboard design through behavioral analysis (Focused on the characteristics of Korean Alphabet and its use) (사용행태 분석에 의한 컴퓨터 키보드 디자인 개선 -한글의 특성 및 사용행태를 중심으로-)

  • 변재형
    • Archives of design research
    • /
    • v.15 no.3
    • /
    • pp.241-248
    • /
    • 2002
  • Researches of Hangul automation have been focused mainly on the set of character system. But, practical problem of using the Korean standard keyboard system of two sets is increment of errors and fatigue due to frequent use of shift keys. The author formulate a hypothesis as follows to solve the problem. 'Changing location and design of shift keys can reduce errors in typing Korean by avoiding interferences with other keys when pressing shift keys.' This study verify the hypothesis by the analysis of experiments using improved keyboard prototypes which have changed layout and design of shift keys. On the result, change of shift key location causes confusion to experienced user. But, while keeping its location, removing other keys at the bottom row and magnifying size of shift keys decrease errors in typing by avoiding interferences. And, the efficiency of typing in Korean is increased, too, because there is not any influence on typing speed. This study focuses on layout and design of shift keys only, but further study for entire layout of keyboard including alternative location of other function keys is needed to improve general usability.

  • PDF

Mutation Analysis in β2-Adrenergic Receptor Gene by Single Strand Conformation Polymorphism (SSCP) and Denaturing High Performance Liquid Chromatography (DHPLC) (SSCP와 DHPLC에 의한 β2-교감신경수용체 유전자의 돌연변이 분석)

  • Park, Sang-Bum;Han, Sang-Man;Nam, Youn-Hyoung;Jang, Won-Cheoul
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2004
  • Up to now, methods for the detection of genetic alterations as single strand conformation polymorphism (SSCP) or denaturing gradient gel electrophoresis (DGGE) have been used. It is too labor-intensive and expensive to serve for routine analysis. Moreover, lower in its sensitivity and specificity being also strongly dependent on the experience of the investigater. To improve these problems, we analysed mutation of ${\beta}_2$-adrenergic receptor gene that controls bronchial asthma by denaturing high performance liquid chromatography (DHPLC) according to ion-pair reversed phase chromatography (IP-RPC). We extracted genomic DNA from 80 asthma patients and then amplified DNA using PCR and analysed PCR product by SSCP and DHPLC. As a result, we analysed mutation frequency is 19 (23.75%) on SSCP and 25 (31.25%) on DHPLC in ${\beta}_2$-adrenergic receptor gene. We conclude that DHPLC is a fast and simple screening method rather than SSCP analysis.

무심연삭공정의 진원도 형성해석

  • 주종남;김강
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.21-25
    • /
    • 2001
  • 기계부품의 소형화 , 고속화, 그리고 저공해, 저소음이 요구되는 세계적인 추세에서 정밀가공기술은 기계 및 전자산 업에서 중요한 위치를 차지하게 되었다. 특히, 무심연삭공정(Centerless Grinding)은 높은 생산성과 정확한 치수 형성의 능력이 있어서 원통형상을 가공하는 중요한 생산공정으로 사용되어 왔다. 예컨대 VCR의 소형 축. Computer Disk Drive, 초소형 모터, 연료분사기등은 쎈터레스 연삭공정을 통하여 높은 정밀도를 얻고 있다. 하지만 이 공정의 특수성과 측정의 어려움으로 인하여 이러한 정밀형상의 형성과정은 아직도 잘 밝혀져있지 않다. 무심연연삭 공정에서는 부품이 기계에 고정되어 있지 않고 공작물 받침날 위에 올려져 있으며 조절바퀴와 연삭바퀴 사이에 눌려져 있다. 조절바퀴가 마찰력으로 공작물을 돌려주며 연삭바퀴에서 연삭가공이 일어나게 된다. 조절바퀴와 연삭바퀴사이의 거리는 기계 자체의 탄성변형으로 인하여 항시 변화하게 되며 이 거리의 변화가 공작물의 정밀형상 형성에 결정적인 영향을 미치게 된다. 본 연구에서는 무심연삭공정중 공작물과 받침날, 조절바퀴, 연삭바퀴의 상대운동을 기하학적으로 해석하였다. 특히 간섭조건을 사용하여 실제 공작물의 운동을 해석하여 순간 명목 절삭깊이를 구하였다. 또한 연삭 특성실험식을 이용하여 수직 연삭력을 구하고 연삭기의 탄성변형을 구하여 순간 실제 절삭깊이를 계산하였다. 그로부터 진원도형성에 관한 기본식을 유도하였다. 본 연구에서 유도된 진원도 형성 식을 이용하여 실험과 동일한 조건으로 컴퓨터 시뮬레이션을 수행하였다. 그리고 원형중의 어떤 이상형상, 즉, 홈또는 돌기는 반복되어서 다른 돌기 또는 홈을 형성 하게되며 그 반복주기는 공작물이 조절바퀴와 연삭바퀴위에 떠있는 각도에 따라 결점 됨을 확인하였다.'유창성' 에 그 목표를 두고 있는 점을 감안한다면, 시작단계부터 반드시 정확한 발음을 지녀야 하는 가의 문제도 생각해 볼 필요가 있다. 경우에 따라서는, 정확한 발음은 그 언어에 대한 숙련도가 점차 높아짐에 따라 이와 병행하여 이루어지는 경우도 흔히 경험하는 일이기 때문이다. 결국 초등영어 교육과정에도 명시되어 있듯이 '...영어에 대한 친숙함과 자신감을 심어주고, 영어에 대한 흥미와 관심을 지속적으로 유지시키는 것이 중요하기' 때문에 무엇보다 중요한 측면은 흥미와 관심을 유지시키는 지적인 학습활동보다는 정의적인 학습활동의 전개가 필요하다고 하겠다. 유리된 AA의 세포독설과 관련된 세포내의 역할에 대해 의문이 제기되었다., PCL에 SOD-1도 경미하게 나타났으나, 경련이 나타난 쥐에서는 KA만을 투여한 흰쥐와 구별되지 않았다. 이상의 APT의 항산화 효과는 KA로 인한 뇌세포 변성 개선에 중요한 인자로 작용할 것으로 사료되나, 보다 명확한 APT의 기전을 검색하고 직접 임상에 응응하기 위하여는 보다 다양한 실험 조건이 보완되어야 찰 것으로 생각된다. 항우울약들의 항혈소판작용은 PKC-기질인 41-43 kD와 20 kD의 인산화를 억제함에 기인되는 것으로 사료된다.다. 것으로 사료된다.다.바와 같이 MCl에서 작은 Dv 값을 갖는데, 이것은 CdCl$_{4}$$^{2-}$ 착이온을 형성하거나 ZnCl$_{4}$$^{2-}$ , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어떠한 용리액에서던지 NH$_{4}$

Evaluation Technique of Ground Densification on Sand Deposit using SASW and Resonant Column Tests (표면파시험과 공진주시험을 이용한 사질토지반 개량평가 시스템의 개발)

  • 김동수;박형춘;김성인
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.41-52
    • /
    • 1999
  • In order to assess the quality and depth of ground densification by compaction, SPT and/or CPT are performed before and after compaction. Both methods are intrusive and one point tests, require a substantial time to evaluate a large area, and their results are quite dependent on the operation technique and soil type. In this paper, the quality and extent of ground densification by compaction was evaluated by using in situ SASW test and laboratory resonant column (RC) test results. SASW test was used to determine the shear wave velocity profiles before and after compaction, and RC test was adopted to determine the correlation between the normalized shear wave velocity and the density of the site, which is almost uniquely independent of confinement. Testing and data reduction procedures of both tests were discussed, and a simplified evaluation procedure of ground densification was proposed. Finally, the feasibility of the proposed method was verified by performing field study at Inchon International Airport Project. Field densities determined by the proposed method matched well with those determined by sand cone tests.

  • PDF

A Diagnosis system of misalignments of linear motion robots using transfer learning (전이 학습을 이용한 선형 이송 로봇의 정렬 이상진단 시스템)

  • Su-bin Hong;Young-dae Lee;Arum Park;Chanwoo Moon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.801-807
    • /
    • 2024
  • Linear motion robots are devices that perform functions such as transferring parts or positioning devices, and require high precision. In companies that develop linear robot application systems, human workers are in charge of quality control and fault diagnosis of linear robots, and the result and accuracy of a fault diagnosis varies depending on the skill level of the person in charge. Recently, there have been many attempts to utilize artificial intelligence to diagnose faults in industrial devices. In this paper, we present a system that automatically diagnoses linear rail and ball screw misalignment of a linear robot using transfer learning. In industrial systems, it is difficult to obtain a lot of learning data, and this causes a data imbalance problem. In this case, a transfer learning model configured by retraining an established model is widely used. The information obtained by using an acceleration sensor and torque sensor was used, and its usefulness was evaluated for each case. After converting the signal obtained from the sensor into a spectrogram image, the type of abnormality was diagnosed using an image recognition artificial intelligence classifier. It is expected that the proposed method can be used not only for linear robots but also for diagnosing other industrial robots.

Evaluation of Mix Design for Asphalt Mixtures by Bailey Method (Bailey Method를 이용한 아스팔트 혼합물 최적배합설계 평가)

  • Lee, Dong-Hang;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4832-4836
    • /
    • 2012
  • In general, there are needed lots of time and experiments for determination of optimum asphalt content and mix design. The experimental results are highly depended on the skill of testers. Bailey suggested the proper aggregate gradation of hot mix asphalt are a function of special size and passing percent of the specified aggregate to reduce the test errors. In this paper, the asphalt mix designs of 19mm dense graded mix and PA-20mm for FHWA were carried out, using Bailey's method. The use of Bailey method can cut down the testing times to get the proper aggregate gradation for asphalt mix design. In case of 19mm dense graded asphalt mixture, the measured values of CA, $FA_c$, $FA_f$ are 0.724, 0.440, and 0.455, which are within the suggested values by Bailey. Also, in case of PA-20 graded asphalt mixture, the measured values of CA, $FA_c$, $FA_f$ are 0.646, 0.476, and 0.450, respectively.