• Title/Summary/Keyword: 숙련도시험

Search Result 49, Processing Time 0.023 seconds

Resilient Moduli of Sub-ballast and Subgrade Materials (강화노반 및 궤도하부노반 재료의 회복탄성계수)

  • Park, Chul-Soo;Choi, Chan-Yong;Choi, Choong-Lak;Mok, Young-Jin
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.54-60
    • /
    • 2008
  • In the trackbed design using elastic multilayer model, the stress-dependent resilient modulus $(E_R)$ is an important input parameter, that is, reflects substructure performance under repeated traffic loading. However, the evaluation method for resilient modulus using repeated loading triaxial test is not fully developed for practical purpose, because of costly equipment and the significantly fluctuated values depending on the testing equipment and laboratory personnel. The this study, the paper will present an indirect method to estimate the resilient modulus using dynamic properties. The resilient modulus of crushed stone, which is the typical material of sub-ballast, was calculated with the measured dynamic properties and the range of stress level of the sub-ballast, and approximated with the power model combined with bulk and deviatoric stresses. The resilient modulus of coarse grained material decreases with increasing deviatoric stress at a confining pressure, and increases with increasing bulk stress. Sandy soil (SM classified from Unified Soil Classification System) of subgrade was also evaluated and best fitted with the power model of deviatoric stress only.

Validation of urinary N-methylacetamide reference material for proficiency test (숙련도시험을 위한 소변 중 N-메틸아세트아미드 표준시료 검증)

  • Lee, Mi-Young
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.339-346
    • /
    • 2014
  • The author assessed the availability of urine reference material for proficiency test provided for laboratories in occupational health. N-methylacetamide is the biomarker of exposure to N,N-dimethyl acetamide, which was used as the substitute for hepatotoxic N,N-dimethylformamide (DMF). N-methylacetamide (NMAC) urine samples of 3 different levels covering the 0.2~2 times of the exposure limit were tested. Stability test up to 180 days (0, 7, 30, 60, 180 days) at 4 different temperatures (-60, -20, 5, $25^{\circ}C$) and homogeneity test were performed for these samples. New analytical condition by GC/MSD using SIM mode (m/z 58, 59) and DB-624 column was investigated for better selectivity, sensitivity and resolution. Urinary NMAC samples showed good homogeneity for 3 levels. These samples also showed good stability up to 180 days. The data of stability and homogeneity of urinary DMAC confirmed the basis of including this item into Korean proficiency test for occupational health laboratories since 2008.

A Study on the Actual Operation Conditions of the Private Security Guard Certification Exam and it's Improvement Plan (신변보호사 자격시험의 운영실태와 개선방안에 관한 연구)

  • Lee, Sanghun
    • Convergence Security Journal
    • /
    • v.14 no.6_2
    • /
    • pp.35-44
    • /
    • 2014
  • Private Security Guard Certification Exam that initiated as the eligibility of private in 2006, has been requested more fulfilling management because that becomes to be recognized at the national certified qualification system in 2013. The findings of this study were as follows: First, it is necessary to expand more exemptions, currently some are mainly police officers. Secondly, it is needed to make to announce the final successful candidates through the opposition proceedings by publishing assumptions answer of the problem and by improving the procedure for determining the successful candidates, and so forth.

A Study of the Application of Digital Photogrammetry to Railroad Rock Slope Investigation System (디지털 사진측량의 철도 암사면 조사시스템 적용에 관한 연구)

  • Ahn, Tae-Bong
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.4
    • /
    • pp.548-556
    • /
    • 2009
  • In order to evaluate applicability of rock cut-slope investigation system, typical clinometer and photogrammetry investigation system were used for rock slopes; first for 7 discontinuities, and secondly, 10 discontinuities, and the results were compared. The first verification was performed depending on discontinuity joint shapes and slope angles, and the second verification was performed depending on shot time and shot locations. The results showed that differences of dip direction $1^{\circ}{\sim}4^{\circ}$, dip $0^{\circ}{\sim}4^{\circ}$. In the second verification test, the differences of dip direction was $0^{\circ}{\sim}6^{\circ}$, and dip $0^{\circ}{\sim}6^{\circ}$. The photogrammetry method for rock slope survey system is quite reliable when clinometer generally shows ${\pm}10^{\circ}$ errors due to surface roughness and investigator.

A Study on Comparison of Density Test Methods for Quality Control of Cement and Mineral Admixture (시멘트 및 혼화재의 품질관리를 위한 밀도 시험방법 비교 연구)

  • Jae-Seung, Lee;Sang-Kyun, Noh;Cheol, Park;Hong-Chul, Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.435-442
    • /
    • 2022
  • In this study, the density of KS L 5110 was compared with that of gas pycnometer and electronic densimeter for efficient density management of cement, blast furnace slag powder and fly ash. Correlation and usability according to the test method were reviewed, and based on the results of the experiment, the availability of alternative test methods was analyzed. As a result of the density test according to test methods, the density of cement, blast furnace slag powder and fly ash tended to decrease in the order of gas pycnometer, KS L 5110 and electronic densimeter. Because the volume range of the sample to be evaluated is different depending on test methods. The coefficient of determination R2 was in the range of 0.71 to 0.93, and the correlation according to test methods showed a relatively good correlation. If correction is applied through correlation, it is analyzed that alternative test methods can be used. As a result of the usability review considering the test procedure, measurement time and coefficient of variation, the gas pycnometer had the simplest test procedure and good reliability. In addition, it is expected that the reproducibility between the testers is relatively high because the skill is not greatly required.

A Study on the development of Test Report Information Service(TRIS) by User survey analysis (사용자 설문분석을 통한 군수품 시험성적서 정보서비스 고도화 방안에 대한 연구)

  • Park, Dongsoo;Lee, Donghun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.405-414
    • /
    • 2017
  • In this study, a survey for a satisfaction evaluation of the Test Report Information Service (TRIS) was conducted. A survey questionnaire on modified Information System Success Model(ISSM) of Delone and Mclean was carried out by 183 users in three groups, such as munition quality assurance agency, munition corporation, and test institute. As a survey result, training on the TRIS was in strong demand in all three groups. An understanding and proficiency of the overall system were different from the work process of each user group. In addition, the munition quality assurance agency needs to enhance the system function with its characteristics. Test institute has necessity of the linkage method with the TRIS depending on the authentication system. User groups are different in the operational method of TRIS between the contractor and cooperation. Accordingly, cooperation needs to be educated continually. This study can help in the construction of a Military Quality Integration Information System to secure the reliability of munitions.

Development of Pre-molded Joint for 230kV XLPE Power Cable (230kV XLPE 삽입형 고무몰드 접속함의 개발)

  • Kim, H.J.;Kim, H.J.;Kim, S.Y.;Song, J.H.;Han, J.H.;Lee, H.L.;Kim, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1564-1565
    • /
    • 2006
  • 현재 전세계적으로 170kV급 이하의 초고압 지중케이블 접속함으로 기존의 현장몰드방식의 TMJ(Tape Molded Joint)와 부품조립방식의 PJ(Prefabricated Joint)보다 조립시간이 짧고 작업자의 숙련도가 높지 않아 경제적이며, 유지보수에 장점을 가진 고무몰드 접속함(PMJ)이 채용되고 있으며, 이러한 추세는 적용 전압급이 점차 상승하면서 230kV급까지 그 비중이 늘어나고 있는 경향을 보이고 있다. 당사에서는 이러한 추세에 발맞추어 154kV급 고무몰드접속함의 개발 당시의 Silicone의 기초물성시험 DATA 획득, 고무몰드 UNIT 및 금형 설계 기술 확립과 접속 공법 개발의 경험을 바탕으로 230kV급 고무몰드접속함의 개발에 성공하였다.

  • PDF

The Research of Improvement and Present Conditions about Qualification System in Private Security (한국 민간경비 자격제도의 현황과 개선방안 연구 - 경비지도사 및 경비원 자격을 중심으로 -)

  • Park, Jang Gyu;Kim, Nam Joong
    • Convergence Security Journal
    • /
    • v.13 no.5
    • /
    • pp.117-127
    • /
    • 2013
  • Even though, the Korean private Security Guard's industry is developing, it did not reached at the expected quality services because of the below cost tendering from flooded small security companies, consequently low pays and fragile benefits occur therefore, the skill level and morale decreased. Also, the private security guards field's education, training and development of expert certification system is not enough. One of the plans to solve these problems can be invigorate the certification system. The improving ways are suggested after the research and the analysis of the certification system as below. First, the qualification system to become a security leader will need to add directly related subject, skill examination and continuous refresh training. Moreover, it needs accurate needed the number of the securities and the reduction of the 1st examination exemption object. Second, the qualified system to be become securities will need to strengthen on standard of qualification and focus on skill evaluation, the job education need to state by the law, also exemption for applicant who approached requirements.

Development and Validation of Analytical Method for Determination of Biphenyl Analysis in Foods (식품 중 비페닐 분석법 개발 및 유효성 검증)

  • Kim, Jung-Bok;Kim, Myung-Chul;Song, Sung-Woan;Shin, Jae-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.4
    • /
    • pp.459-464
    • /
    • 2017
  • Biphenyl is used as an intermediate in the production of crop protection products, a solvent in pharmaceutical production, and as a component in the preservation of citrus fruits in many countries. Biphenyl is not authorized for use and also does not have standards or specifications as a food additive in Korea. National and imported food products are likely to contain biphenyl. Therefore, control and management of these products is required. In this study, a simple analytical method was developed and validated using HPLC to determine biphenyl in food. These methods are validated by assessing certain performance parameters: linearity, accuracy, precision, recovery, limit of detection (LOD), and limit of quantitation (LOQ). The calibration curve was obtained from 1.0 to $100.0{\mu}g/mL$ with satisfactory relative standard deviations (RSD) of 0.999 in the representative sample (orange). In the measurement of quality control (QC) samples, accuracy was in the range of 95.8~104.0% within normal values. The inter-day and inter-day precision values were less than 2.4% RSD in the measurement of QC samples. Recoveries of biphenyl from spiked orange samples ranged from 92.7 to 99.4% with RSD between 0.7 and 1.7% at levels of 10, 50, and $100{\mu}g/mL$. The LOD and LOQ were determined to be 0.04 and $0.13{\mu}g/mL$, respectively. These results show that the developed method is appropriate for biphenyl identification and can be used to examine the safety of citrus fruits and surface treatments containing biphenyl residues.

Folate retention in Namul according to various heating methods (다양한 열 처리방법에 대한 나물류의 엽산 잔존율)

  • Jung, Jae Eun;Jeong, Hea-Jeong;Hyun, Taisun;Park, Su-Jin;Chun, Jiyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.425-431
    • /
    • 2019
  • Selected leafy vegetables, widely used for Korean Namul dishes, were heat-treated in different ways and their folate retention was investigated. The Lactobacillus casei method was applied for folate estimation and validated to ensure reliability of analytical data. The folate content in Namul highly varied, from 29.7 to $293.4{\mu}g/100g$, depending on the heating methods and the types of vegetables. Most of the Namul variants showed increased folate content on heat treatment. Frying yielded higher folate retention than the other cooking methods (blanching, steaming, baking, and panfrying), and pig weed showed the highest folate retention (3.3 times, $293.4{\mu}g/100g$). L. casei assay for folate estimation showed 95.7% recovery and relative standard deviations less than 2% for both reproducibility and repeatability, indicating good accuracy and precision. Quality of the folate assay was assured by monitoring a quality control chart and a proficiency test (z-score= -0.1) during the entire of study.