• Title/Summary/Keyword: 수평 장치장

Search Result 46, Processing Time 0.023 seconds

Use of Electromagnetic Inductance for Salinity Measurement in Reclaimed Saline Land (전자장 유도 장치를 이용한 간척지 토양의 염농도 측정)

  • Jung, Yeong-Sang;Lee, Won-Ho;Joo, Jin-Ho;Yu, Il-Ho;Shin, Wan-Sik;Ahn, Yeol;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.2
    • /
    • pp.57-65
    • /
    • 2003
  • Mapping of salinity distribution in the reclaimed lands was attempted by using the electromagnetic inductance technique. Field study was conducted to monitor ground conductivity with an electromagnetic inductance, EM 38 (Geonics), and electrical conductivity of the saturated extract, ECe of the soils, at the Daeho reclaimed land. EM values of horizontal mode, EMh, and vertical mode, EMv, mode were recorded at the interval of $2m{\times}2m$ from the ground. Soil samples were taken through the profile down to 100cm for calibration. ECe of poor drained area of Daeho, were in the range of $19.50-91.50ds\;m^{-1}$, while ECe of well-drained area ranged from $1.10-34.40ds\;m^{-1}$. Multiple regression equations for the measured EMv, EMh, and ECe were highly significant. The EMh showed higher correlation with ECe than EMv. With the multiple equation, ECgM could be calculated. Correlation between ECe and ECgM was the highest ($r=0.753^{***}$), when EMI readings were taken on the ground. The relationships were highly significant below 30 cm height of measurement, With the EM38 measurement, the salinity distribution was effectively expressed for the experimental filed in Daeho reclaimed land.

Analysis of ELF Magnetic Field Reduction Ratio on Passive Loop Using Scale Down Model of Transmission Line (축소 모델을 이용한 수동 루프 송전선 자기장 저감율 분석)

  • Cho, Yeun-Gyu;Myung, Sung-Ho;Lee, Jae-Bok;Chang, Sug-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1231-1239
    • /
    • 2006
  • In this research magnetic field reduction effect of each passive loop was analyzed by using the scale down models of transmission lines. This paper examined magnetic field reduction effect of the passive loop that will be applied to actual facility through the experiment, which is about double vertical transmission line and horizontal transmission line. Consequently, by confirming the fact that magnetic field reduction effect can be obtained to 50 % by passive loop without reactive compensation, we insured technology about application of passive loop. And the case of 3 turns of loop showed two times reduction effect than that of 1 turns of loop in reducing magnetic field. Vertical passive loop is more efficient than horizontal passive loop in the aspect of reducing magnetic field on double vertical transmission lines. What is more, vertical passive loop showed good effect of reducing magnetic field in a far distance as well as in a short distance.

Performance and Manufacture of the Apparatus Generating Artificial Magnetic Field of 3-axis Type (3축형 인공자장발생장치의 제작과 성능에 관한 연구)

  • 이유원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.181-188
    • /
    • 2003
  • The objects of this study were to discuss the performance of its using magnetic compass and to do a trial manufacture of the apparatus generating artificial magnetic field of 3-axis type to assess the performance of compass using terrestrial magnetism in the various magnetic field. The results obtained were summarized as follows: The magnetic field of each axis showed the linearly increase in accordance with the increase of electrical current. Average range difference between measured and calculated values was 0.33∼1.93μT and there were no big difference. The magnitude and direction of magnetic field showed some change in the edge of Helmholtz coil, but it appeared to stabilize in the center. In the horizontal magnetic force of 0.30gauss and 0.40gauss, the measured and calculated values of the damping characteristic of magnetic compass showed a good agreement. However, the confidence level was low at the horizontal magnetic force of 0.50gauss.

Fabrication and Test Results of Superconducting Magnet for Crystal Growing System (실리콘 웨이퍼 성장용 초전도 마그네트의 제작 및 성능평가)

  • Sim, K.D;Choi, S.J.;Kim, K.H.;Han, H.H.;Kim, H.J.;Jin, H.B.;Lee, B.K.;Kwon, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.824-827
    • /
    • 2002
  • 12inch 이상의 웨이퍼 성장에는 실리콘 용탕의 대류를 억제하여 웨이퍼의 순도를 높이기 위해 자기장 특히, 웨이퍼의 성장방향에 수직인 '수평자장'을 인가하는 방법이 사용된다. 현재 '자기장인가 방식', 특히 초전도를 사용한 자장인가 방식이 직경 1600mm에 이르는 용탕의 용액을 제어하는 유일한 방법으로 받아들여지고 있다. 본 논문에서는 12inch 실리콘 웨이퍼 성장용 초전도 마그네트 개발의 전단계로 개발중인 8inch 웨이퍼 성장용 수평자장형 초전도마그네트의 제작과정과 성능평가 결과에 대해 다루었다. 본 연구를 통해 액체헬륨의 증발을 최소화하기 위한 재응축형 극저온 용기에 대한 기술이 개발 되었으며, diode를 이용한 ��치보호부, HTS 전류리드의 ��치 protection부 등의 부속기술이 개발되었다. 초전도 마그네트는 내경 1400mm의 saddle type으로 이의 제작에 있어 많은 기술적 난재들을 경험해야 했다. 전체 시스템에 대한 성능평가 결과, 극저온용기 및 부속장치에 대한 결과는 만족스러웠으나, 코일부의 성능은 계획한 목표에 미치지 못했다.

  • PDF

Designing a Horizontal Yard Layout in Port Container Terminals Using Simulation (시뮬레이션을 이용한 컨테이너 터미널의 수평배치 장치장의 배치도 설계)

  • Jeon, Su-Min;Kim, Kap-Hwan;Ryu, Kwang-Ryel
    • IE interfaces
    • /
    • v.20 no.1
    • /
    • pp.49-57
    • /
    • 2007
  • The design of the container stacking yard influences significantly the productivity of handling operations in port container terminals. This study proposes methods for determining specifications of the yard considering the travel distance of vehicles and the storage capacity of yards. For a given length and width of a yard, it is discussed how to determine the layout and the dimension of yard blocks. The alternatives of the yard layout are evaluated by using a simulation study.

A Study on the Detecting Accuracy of EM Induction Survey Data of Buried Utility (전자유도 탐사를 이용한 지하매설물 탐지 정확도 분석)

  • Kwon, Hyoung-Seok;Choi, Joonho;Hwang, Daejin;Kim, Munjae;Yoon, Jeoungseob
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.4
    • /
    • pp.73-81
    • /
    • 2008
  • Electromagnetic induction surveys are one of the useful methods to detect the location and buried depth of underground utilities by measuring horizontal and vertical magnetic fields. It can effectively detects single buried utility with the accuracy of within 20 cm. However when another utility is buried near to target one, the accuracy of utility location considerably decreases due to the distortion of magnetic fields caused from adjacent utility. This study shows the ways to verify the location and buried depth of target utility when magnetic fields does not show symmetric distribution due to adjacent another utility. Using Bluetooth wireless communication tools, we developed the way to records measured magnetic fields to handheld PDA. We investigated the criteria for minimum distance of two adjacent utilities to separate the individual responses through field model test.

  • PDF

Comparative Analysis of Track-Bridge Interaction of Sliding Slab Track and Rail Expansion Joint for Long-Span Railway Bridge (장경간 철도 교량에 적용된 슬라이딩 궤도와 레일신축이음장치의 궤도-교량 상호작용 비교)

  • Lee, Kyoung Chan;Jang, Seung Yup;Lee, Jungwhee;Choi, Hyun Sung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.169-177
    • /
    • 2016
  • Sliding slab track system, which consists of low friction sliding layer between track slab and bridge deck, is recently devised to reduce track-bridge interaction effect of continuously welded rail(CWR) without applying special devices such as rail expansion joint(REJ). In this study, a series of track-bridge interaction analyses of a long-span bridge with sliding slab track and REJ are performed respectively and the results are compared. The bridge model includes PSC box girder bridge with 9 continuous spans, and steel-concrete composite girder bridge with 2 continuous spans. The total length of the bridge model is 1,205m, and the maximum spacing between the two fixed supports is 825m. Analyses results showed that the sliding slab track system is highly effective on interaction reduction since lower rail additional axial stress is resulted than REJ application. Additionally, horizontal reaction forces in fixed supports were also reduced compared to the results of REJ application. However, higher slab axial forces were developed in the sliding slab track due to the temperature load. Therefore, track slab section of the sliding slab track system should be carefully designed against slab axial forces.

Characteristics of Horizontal 2D Velocity Distribution in Meandering Channels (사행수로에서 수평 2차원 유속분포 특성)

  • Seo, Il-Won;Song, Chang-Geun;Park, Sung-Won;Shin, Jae-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.415-420
    • /
    • 2009
  • 공학 분야에 있어서 수치 해석적 연구가 많은 주목을 받고 있다. 경제적 측면을 비롯한 다양한 측면에 있어서 모의의 간편성으로 인해 하천에서의 수리학적 거동모의에 수치해석 모의 분석법이 쓰이고 있는데 모의결과의 비교 및 검증을 위해서는 현장 실험 혹은 모형실험이 선행되어야만 한다. 본 연구에서는 강재로 제작된 S자 형태의 만곡부를 두 개 갖고 있는 사행수로 실험 장치를 제작하여 두 가지 유량조건 (30, 60 ${\ell}$/sec.)과 두 가지 하류단 수위조건 (30, 40 cm)에 대하여 수평 2차원 유속분포 자료를 이용하였다. 유속장의 자료는 Sontek사에의 3차원 micro-ADV(Acoustic Doppler Velocimeter)를 이용하여 측정하였다. 주 흐름은 직선구간에서는 중앙에서 최대 유속을 나타내며, 좌우대칭적인 유속분포의 모습을 보이고, 만곡부에서는 수로안쪽을 따라 최대유속이 발생하였다. 이는 만곡부의 정점부분에서의 이차류 발생 및 소멸에 의한 연직방향 유속분포를 통해 발생되는 현상이라 사료된다. 또한 본 연구에서는 2차원 하천해석 상용프로그램인 RAMS (베타버젼)와 SMS를 이용하여 흐름해석을 수행하였다. 실험 자료와의 비교를 통하여 두 가지 상용프로그램의 경우 모두 다소 과대 산정되는 것을 알 수 있었고, 만곡부와 직선부의 유속분포에 대한 모의결과는 RAMS (RAM2)의 결과가 보다 실험결과와 잘 일치하는 것으로 분석되었다. 위와 같은 유속분포의 분석을 통하여 각각의 상용소프트웨어의 적용성을 비교해 보았으며 향후 오염물질 거동해석 모형을 실험수로에 적용하여 그 결과를 비교할 수 있을 것으로 예상한다.

  • PDF

Efficient generation of concentric mosaics using image-strip mosaicking (스트립 영상 배치를 이용한 동심원 모자익의 효율적인 생성)

  • Jang, Kyung Ho;Jung, Soon Ki
    • Journal of the Korea Computer Graphics Society
    • /
    • v.7 no.2
    • /
    • pp.29-35
    • /
    • 2001
  • In general, image-based virtual environment is represented by panoramic images created by image mosaic algorithm. The cylindrical panoramic image supports the fixed-viewpoint navigation due to the constraints of construction. Shum proposed concentric mosaics to allow users to navigate freely within a circular area[10]. It is constructed by a sequence of images which is acquired from a regularly rotating camera. Concentric mosaics technique, proposed by Shum, is considered as 3D plenoptic function which is defined three parameters : distance, height and angle. In this paper, we suggest an effective method for creating concentric mosaics, in which we first align a set of strip images on the cylinder plane and stitch the aligned strips to build a panoramic image. The proposed method has no constraints such as regular panning motion of camera. Furthermore, our proposed method minimizes the use of interpolation image to create a novel view images from the concentric mosaics. It allows the result image on a novel view to have better quality with respect to the number of input images.

  • PDF

Helmholtz Coil and Performance of Magnetic Compass (인공자장발생장치와 자기 컴퍼스의 성능)

  • Ahn, Young-wha;Jeong, Kong-heun;Ahn, Jang-young;Sin, Hyeong-il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.2
    • /
    • pp.111-116
    • /
    • 1983
  • In order to furnish the fundamental data for the domestic production of magnetic compass and the prescription of standardization about it in Korea, authors made the helmholtz coil and investigated the characteristics of them. Subsequently, the damping curves of T190 and T165 compasses in the helmholtz coil were measured and analyzed the performance of those compass. The results obtained are as follows; 1. The relation between electric current (I sub I) to flow in the helmholtz coils, that the thickness of coil is 1mm, diameter 1m, winding number 117, and intensity of magnetic field is presented as follows. Vertical magnetic force: Z(Gauss)=0.34+1.506 I sub(i) Horizontal magnetic force: H(Gauss)=0.183+1.506 I sub(i) 2. Period of T190 compass is longer than T165 compass in all horizontal magnetic force. In the amplitude, the former is larger than the latter above 0.08 Gauss, but this phenomenon is opposed to that below 0.08 Gauss. 3. As the porizontal magnetic force is intensive, period of magnetic compass is short, amplitude is large, and damping degree and damping factor are small. The time elapsed to the principal points of damping curve is proportional to the -0.65 power of the horizontal magnetic force.

  • PDF