• Title/Summary/Keyword: 수평 유지

Search Result 489, Processing Time 0.025 seconds

An Experiment of Structural Performance of Expansion Joint with Rotation Finger (가변형 핑거 조인트를 가지는 신축이음장치의 구조 성능 실험)

  • Yoo, Sung won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.170-175
    • /
    • 2018
  • For the seismic performance, it is necessary to prevent the destruction of the expansion joint device due to the appropriate deformation of the expansion joint device due to the seismic force. Recently, the hinge is installed on the fingering of the expansion joint device in Korea, New products are being developed. In this paper, we have experimentally evaluated the real scale resistance of the expansion joints with rotational finger joints against load at right angle to the bridge axis. Experimental results show that the maximum horizontal displacement is about 21.1mm for conventional stretch joints and 51.00mm for seismic stretch joints. It is presumed that the existing expansion joint test specimen is resistant to the load in a direction perpendicular to the throat axis, and then the bending and shear deformation of the finger are excessively generated and the fracture phenomenon is likely to occur. On the other hand, in the case of the seismic expansion joint, the deformation of the load due to the load is absorbed by the hinge of the finger with respect to the load in the direction perpendicular to the throat, so that only horizontal deformation in the direction of load action.

Estimation of Compressive Strength of Reinforced Concrete Vertical and Horizontal Members Using Ultrasonic Pulse Velocity Method (초음파속도법을 이용한 철근콘크리트 수직 및 수평부재의 압축강도 추정)

  • Hong, Seonguk;Lee, Yongtaeg;Kim, Seunghun;Kim, Jonghyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.197-205
    • /
    • 2018
  • Recently, remodeling is increasing due to aging of buildings. Therefore, the importance of quality control of structures has been raised, and interest in safety diagnosis and evaluation of structures has been increasing. In order to accurately diagnose old buildings, a diagnostic evaluation technique is needed to evaluate the defects of structures in advance. In addition, as the safety diagnostic criteria for reconstruction are improved and the weight of structural safety is increased, researches on safety diagnosis techniques of structures that are faster and more reliable are needed. In this study, we tried to estimate the compressive strength by examining the correlation between ultrasonic pulse velocity and compressive strength of a 1 story structure consisting of vertical and horizontal members of reinforced concrete using ultrasonic pulse velocity method, which is one of the nondestructive testing methods. The purpose of this study is to examine the applicability in the field. As a result, the estimated average error rate of the compressive strength of the structure using the ultrasonic pulse velocity method was 28.7%, which confirmed the applicability in the field. However, in order to increase the accuracy of the estimation, the necessity of the reliable diagnostic method using the composite nondestructive testing method was confirmed.

Behavior Evaluation of Thin Bonded Continuously Reinforced Concrete Overlay on Aged Jointed Concrete Pavement(2) (노후 줄눈 콘크리트 포장 보수를 위한 얇은 연속 철근 콘크리트 덧씌우기 포장의 거동 평가(2))

  • Ryu, Sung-Woo;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.101-110
    • /
    • 2010
  • In this paper, it has been studied about the CRCO to maintain or rehabilitate the aged JCP. The CRCO and JCO was constructed at useless section of Seo-Hae-Ahn express highway in South Korea. The performance evaluation was conducted. Especially, it was focused on the roll of longitudinal reinforced steels inserted into the CRCO. On crack survey results from field construction section, the reflection cracks at joint of the existing pavement occurred in CRCO. However, due to the constraints of longitudinal reinforced steels, crack width was small. Total crack length and quantity in the CRCO more than that in the JCO. And crack spacing in the CRCO was narrower than it in the CRCP. Through the bonding strength test results, if the cold milling and cleaning as well as surface treatment is applied, there will be no debonding problem at interlayer in the early age. From analysis of the horizontal behavior at the joint, the longitudinal reinforced steels constrained crack width which became wider than initial state over time. Also, that steel in the CRCO reduced the horizontal movement due to temperature variation(4 times than that in the JCO). But, if interface is debonded, the roll decreased. Vertical VWG data showed that CRCO did not occur debonding problem at steel location, but there was some problem in JCO. It was confirmed by field coring. The tensile strain appeared in the CRCO, But the compressive strain occurred in the JCO in early age. Through the FWD test result, deflection in the CRCO was less than that in the JCO. And K value in the CRCO was greater than it in the JCO.

Characteristics of Material Function Related to Permeability and Compressibility for Soft Clay Ground (투수 및 압축에 대한 연약 점토지반의 물질함수 특성)

  • Lee, Song;Jeon, Je-Sung;Yi, Chang-Tok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.183-194
    • /
    • 2004
  • It's essential process to study non-linear material function related to characteristics of compressibility and permeability when we predict the consolidation behavior of soft clay ground. In this study, laboratory tests were conducted to find out the material function using marine clay. Standard oedometer test and Rowe cell test were performed with conditions, which were classified into vertical drainage only, radial drainage only and vertical-radial drainage case. Modified oedometer test equipment was developed to find out the material function and special extrusion device was originated to minimize the sample disturbance effect. Reliability of the results in modified oedometer test could be confirmed by comparing with the Rowe cell's one. Effective stress - void ratio - permeability relations were analyzed using all testing results. As a result, void ratio with effective stress level could be expressed by the power function and permeability with void ratio could be expressed by exponential function. In soft clay with high initial water content and low shear strength, non-linear characteristics related to compressibility and permeability varied with wide range by the effective stress levels. It's important to note that non-linearity of the material function should be considered at prediction of the consolidation behavior.

Image-based Water Level Measurement Method Adapting to Ruler's Surface Condition (목자판 표면 상태에 적응적인 영상 기반 수위 계측 기법)

  • Kim, Jae-Do;Han, Young-Joon;Hahn, Hern-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.9
    • /
    • pp.67-76
    • /
    • 2010
  • This paper proposes a image-based water level measurement method, which adapt to the ruler's surface condition. When the surface of a ruler is deteriorated by mud, drifts, or strong light reflection, the proposed method judges the pollution of ruler by comparing distance between two levels: the first one is the end position of horizontal edge region which keeps the pattern of ruler's marking, and the second one is the position where the sharpest drop occurs in the histogram which is construct using image density based on the axis of image height. If the ruler is polluted, the water level is a position of local valley of the section having a maximum difference between the local peak and valley around the second level. If the ruler is not polluted, the water level is detected as the position having horizontal edges more than 30% of histogram's maximum value around the first level. The detected water level is converted to the actual water level by using the mapping table which is construct based on the making of ruler in the image. The proposed method is compared to the ultrasonic based method to evaluate its accuracy and efficiency on the real situation.

Experimental Study on Loading Capacity of SY Corrugated Steel Form for RC Beam and Girder (SY 비탈형 보거푸집의 내하성능에 관한 실험적 연구)

  • Bae, Kyu-Woong;Boo, Yoon-Seob;Hwhang, Yoon-Koog;Shin, Sang-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.32-39
    • /
    • 2021
  • Recently, necessities of steel form for reinforced concrete beam and girder have been emphasized in building structures for the reduction of the construction period and the labor cost. SY Beam was developed for the these purposes and is roll-formed using thin steel plate. On this research, we tried to evaluate and verify the performance and behavior of SY Beam under construction loading stage as like pouring in situ concrete. For the standard shape of SY beam, structural modelling with various steel thicknesses has carried out using MIDAS GEN program. From results of modelling, the width and height of SY Beam were determined 600mm and 400mm respectively. For 3 SY Beams, the loading experiment was performed to measure vertical and horizontal displacement under stacking sand, concrete block, and bundle of rebar. As a result, the vertical deflection showed a tendency to decrease as the thickness increased. In the horizontal displacement, the trend according to the thickness was not clearly observed. From the evaluation on the loading experiment, it is considered that the SY Beam can secure both workability and structural safety. In particular, the SY Beam(1.2mm) hardly generates horizontal displacement, so it has excellent load-bearing capacity. So, we judged that the SY Beam with 1.2mm steel plate has excellent performance and consider to be immediately commercially available.

교류형 플라즈마 방전 표시기 방전유지 전압의 전압 상승 시간의 변화에 따른 방전 현상의 변화

  • 김중균;양진호;윤차근;황기웅
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.229-229
    • /
    • 1999
  • 교류형 플라즈마 방전 표시기(AC Plasma Display Panel, AC PDP)의 구동에서의 방전 현상은 기입방전, 유지방전, 소거 방전이 있다. 이중 유지 방전은 표시장치로서의 휘도와 계조의 표현을 위한 방전으로 표시기로서의 효율을 결정하게 된다. 본 연구에서는 유지 방전 전압의 상승 시간의 변화에 따른 방전현상과 휘도, 효율의 변화를 살펴 보았다. 방전 현상에서의 가장 큰 변화는 교류형 플라즈마 방전 표시기의 방전 개시 전압과 방전 유지 전압의 변화이다. 유지 전압의 상승시간이 증가할수록 방전 개시 전압과 방전 유지 전압의 변화이다. 유지 전압의 상승 시간이 증가할수록 방전 개시 전압과 방전 유지 전압의 차(sustain margin)는 감소하여 상승 시간이 1$\mu$s/100V 이상의 영역에서는 방전 개시 전압과 방전 유지 전압이 차이가 없어지게 된다. 이는 방전 유지 전극 위의 유전체에 쌓이게 되는 벽전하(wall charge) 양의 감소에 의한 방전 약화의 영향을 보여질 수 있다. 그러나 방전 유지 전압의 형태와 전류의 시간적인 변화를 살펴보면 이러한 약한 방전은 벽전하의 감소에 의한 방전 시의 전계 감소보다는 방전 전류의 발생 시간이 방전 전압이 증가하여 최고점에 이르지 못한 시간에 위치하여 방전이 형성될 때의 전계가 강하지 못하기 때문인 것을 알 수 있다. 방전 전류를 측정한 결과에 의하면 방전 전류의 시작은 변위 전류가 흐르고 난 후부터 시작되며 그 결과 방전 전류가 최고점에 도달하는 시간은 방전 전압 상승 시간이 길어질수록 낮은 전압에서 형성되게 된다. 또한 방전 유지 전압의 상승 시간이 길어질수록 플라즈마 방전표시기의 휘도와 효율은 낮아지고 이 결과 또한 약한 전계에서의 방전에 의한 결과로 생각되어진다.플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인 모양을 가지는 성장의 경우도 cluster 밀도, cluster 모양, cluster의 양 축 방향 길이 비, 양 축 방향의 평균 팔 넓이로부터 각 축 방향의 분산 장벽을 얻어낼 수 있을 것으로 보인다. 기대할 수 있는 여러 장점들을 보고하고자 한다.성이 우수한 시

  • PDF

Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system) (개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례)

  • Hong, Tae-Young;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.423-430
    • /
    • 2016
  • The implant prosthesis can be divided into the screw retained prosthesis and cement retained prosthesis. Each type has advantages as well as disadvantages which is unfavorable to maintain the implants. To overcome these drawbacks, T-screw system was developed. T-screw system which utilizes a lingual direction of the screw to retain the implant prosthesis, has advantages of retrievability of the prosthesis, passive fit, and possibility to form esthetic and functional occlusal surface. The prior prosthesis which utilized horizontal screws had difficulty in fabrication especially in the case of multiple units, and also limited use with all-ceramic prosthesis. In this case, fabricating the implant prosthesis by using the T-screw system showed superior results in easy maintenance, esthetics, and also functions. In addition, we are to report the method of using the T-screw system in implant prosthesis, such as multiple units of implant prosthesis and all ceramic prosthesis.

Mandibular implant-natural tooth retained overdenture using magnetic attachment with stress breaker (하악에서 완압형 자성 어태치먼트를 부착한 임플란트-자연치 피개 의치: 10년 증례보고)

  • Park, Eun-Chul;Lee, Su-Yeon;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.378-386
    • /
    • 2015
  • Overdenture has the advantage of improving the stability and retention of the denture but the abutment may be easily affected by caries or periodontal disease and the thin denture can be easily broken. The magnetic attachment overdenture has a high vertical retention but a low horizontal retention, thus, exerting a less disruptive force to the abutment or implant and shows less abrasion or damage compared to other mechanical retainers. Denture fractures in overdenture is caused by the thin denture base as the attachment is inserted, but it may also be caused by the difference in detrusion between soft tissue and hard tissue, and between an implant and a natural tooth. To compensate this shortcoming, a magnetic attachment with a silicone ball inserted in the magnet was developed as we report a successful case using this specific type of magnetic attachment overdenture.

Maintenance and Dynamic Behavior of Advanced Spherical Bearings under Railway Open-Steel-Plate-Girder Bridges (판형교에서 개량된 스페리칼받침의 유지보수 및 동적 거동)

  • Choi, Eun-Soo;Lee, Hee-Up;Lee, Seung-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.165-175
    • /
    • 2008
  • Line type rigid bearings for Open-Steel-Plate-Girder railway bridges have several problems in service, and they are unstable structurally. A series of lateral resistance tests were performed for a retrieved line type bearing. A spherical bearing with advanced maintenance-capability and a device to resist the up-lift was developed and replaced the existing ones. An experiment of maintenance for a new spherical bearing under real Open-Steel-Plate-Girder bridge was conducted and their good maintenance performance was proved. Also, a test against up-lift was performed for the bearing. The dynamic behavior of the bridge was measured and analyzed for the two cases of the existing and replaced bearings. Therefore, the suitability of the new spherical bearings on the railway bridge was improved.