• Title/Summary/Keyword: 수평 변위

Search Result 732, Processing Time 0.023 seconds

Experimental Study on Seismic Performance Evaluation of Lake Dike Structures under Earthquake Loading (지진하중에 의한 방수제 구조물의 내진성능 평가를 위한 실험적 연구)

  • Shin, Eun-Chul;Kang, Hyeon-Hoe;Kim, Tae-Jin;Chae, Young-Su;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.3
    • /
    • pp.53-62
    • /
    • 2011
  • This paper presents the characteristics behavior of dike structure and foundation ground through the shaking table model test. The vibration loadings of design earthquake acceleration of 0.154g was applied to this laboratory model test regarding on dike structure and foundation ground under the structure. The model was formulated with 1/100 design of representative cross section for evaluating the effectiveness of vibration. Based on the test results, we can analysis the behavior of lateral displacement and settlement characteristics of structure under the earthquake loading. The pore water pressure was also monitored in the upper, middle and lower layers of ground. Finally, the actual displacements and pore water pressure of the structure can be predicted by using the results of the laboratory shaking table test.

A Study on the Effects of Chemical Grout on the Shear Strength of Fresh Granite Joints (신선한 화강암 절리면에서 약액에 의한 전단강도의 변화에 대한 연구)

  • Chung, Hyung Sik;Lee, Seung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.99-106
    • /
    • 1990
  • This study was aimed to see the effect of chemical grout on fresh granite joint shear strength. The grouting chemical used in this study was composed of 25% water glass. Direct shear tests were performed on the chemical filled joints, which had been made artificially with granite. The test results show that chemical grouted rock jonts have markedly reduced shear strength comparing with the ungrouted fresh joints and they sheared within chemical grout before the rock to rock contact had been established, while the ungrouted joint sheared between rock surfaces from the beginning of shear deformation. With chemical grouted joints the shear stress slowly reached its maximum without showing distinct peak shear strength. Therefore the shear stiffness of joints were decreased with increasing thickness of grout. but the shear strain at failure was increased with it.

  • PDF

A validity study on SSI analysis by comparing the complete system model and the underground structure fixed-end model (연속체 모델과 지하구조물 고정단 모델의 비교를 통한 SSI 해석의 타당성 연구)

  • You, Kwang-Ho;Kim, Seung-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.757-772
    • /
    • 2018
  • Recently, earthquakes have occurred in large cities such as Gyeongju and Pohang, and seismic analysis studies have been actively conducted in various fields. However, since most of the previous seismic analyses have dealt with ground structures and the ground separately, there is a lack of a study on the complete soil-structure dynamic interaction. Therefore, in this study, a sensitivity analysis is conducted with MIDAS GEN and MIDAS GTS NX to apply the underground structure fixed-end model considering only the building and the complete system model considering both the building and the ground, respectively and the validity of dynamic analysis considering SSI is examined. As a result of the study, in most conditions it is found that the maximum horizontal displacement of the tall building in case of the underground structure fixed-end model is estimated to be smaller, the bending stress is larger, and the range of the weak part is smaller than that of the complete system model. Therefore, it is expected to be more reasonable to use the complete system model considering soil-structure interaction in seismic analysis.

Volumetric Image System for High Efficiency Video Coding (고효율 비디오코딩을 위한 입체영상시스템)

  • Kim, Sang Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.515-520
    • /
    • 2016
  • Volumetric image system has many applications recently in education, 3D movie, medical images but these applications have several problems that need to be overcome. Volumetric display may process a amount of visual data and design the high efficient vision system for realtime display. In case of stereo system for volumetric display motion vectors, disparity vectors from the stereoscopic sequences and residual images with the reference images has been transmitted, and the stereoscopic sequences have been reconstructed at the receiver for volumetric display. So central issue for the design of efficient volumetric image system lies in selecting an appropriate stereo matching and robust vision system. In this paper, we proposed high efficient vision system, which design vision stage with rotating and moving horizontally, and match the successive stereo image efficiently. In experimental results with volumetric image system, the proposed method represents high efficiency with minimizing error and low computational load for volumetric display.

A Study on the Numerical Modeling Criteria for Underground Openings (지하공동굴착의 수치해석방법 적용기준 설정연구)

  • 이경진
    • The Journal of Engineering Geology
    • /
    • v.5 no.1
    • /
    • pp.31-44
    • /
    • 1995
  • The puppose of this study is to propose the numerical modelling criteria for underground opening, rock mass continuum is regarded as homogeneous rock behaved linear elastic. The results of this study are summarized as follows: - Boundaries of the finite element mesh should be located at least 6 radii away from the center of the opening. - For circular openings, tension only developed when $K_0$ was less than one-fourAs the ratio of initial horiwntal to vertical stress increased, the inward springline movement increased and the inward crown movement decreased. - The displacement patterns developing for opening I shaped horse-shoe and opening II shaped powerstation are similar to those for circular openings. For both type opening I and opening II, stress concentrations develop at the intersection of the wall and floor. Greater stress concentrations are found for the type opening II.

  • PDF

Estimation of Fatigue Life of Reinforced Asphalt Pavement Overlay against Reflection Cracking due to Flexural Fracture (보강 덧씌우기 아스팔트 포장의 휨파괴에 의한 반사균열 피로수명 추정)

  • Doh, Young-Soo;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.2 no.4 s.6
    • /
    • pp.101-109
    • /
    • 2000
  • This study was performed to estimate fatigue life of polymer-modified and reinforced overlay asphalt mixtures with respect to reflection cracking in asphalt overlay pavement. In order to achieve the goal, the expedited reflection cracking test method was developed and applied to various mixtures and the results were compared one another with respect to the resistant characteristics of reflection cracking. The theoretical prediction equation of fatigue life for each mixture was suggested based on statistical analysis of experimental test results in the flexural failure mode. Since coefficients of correlation between estimated values and measured values were very high ($r^2=0.95$ or higher), the prediction model can be used for relative comparison of various pavement overlay choices to be used in the field.

  • PDF

Advanced analysis and optimal design of space steel frames accounting for nonlinear behavior of connections (접합부의 비선형 거동을 고려한 공간 강뼈대 구조물의 고등해석과 최적설계)

  • Choi, Se Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.683-694
    • /
    • 2004
  • Advanced analysis and optimal design of semi-rigid space steel frames were presented. The advanced analysis can predict the combined nonlinear effects of connection, geometry, and material on the behavior and strength of semi-rigid frames. The Kishi-Chen power model was used to describe the nonlinear behavior of semi-rigid connections. Geometric nonlinearity was determined using stability functions. Material nonlinearity was determined using the Column Research Council (CRC) tangent modulus and the parabolic function. The direct search method proposed by Choi and Kim was used as optimization technique. One by one, the member with the largest unit value evaluated using the LRFD interaction equation were placed adjacent to a larger member selected from the database. The objective function was assumed to be the weight of steel frame, while the constraint functions were load-carrying capacities, deflections, inter-story drifts, and the ductility requirements. The member sizes determined using the proposed method were compared to those derived from the conventional LRFD method.

Passive Force Acting on the Kicker Block Used to Support a Raker in Soft and Weathered Soil (연약지반과 풍화토지반에서 경사고임대 지지블록의 수동토압 산정)

  • Kim, Tae Hyung;Park, Lee Keun;Kim, Tae O;Jin, Hyun Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.801-813
    • /
    • 2017
  • Passive force acting on the kicker block used to support a raker is different dependent on soil's type. The passive force incorporating a factor of safety is considered for design of the retaining wall. However, an actual passive force developing on the kicker block is overestimated and it may lead to an unsafe design. In this study, the actual passive forces acting on the kicker block in soil ground are evaluated using 3-D Finite Element Program, PLAXIS. Soft and weathered soils are selected as a soil ground. The relation curves between horizontal displacement and actual passive force of the kicker block for each soil ground are obtained through numerical analyses. From the curves, the actual passive forces are determined as a yielding point, which are about 55.5% and 66% of Rankine's passive forces in soft and weathered soils, respectively.

Seismic Isolation Effects Due to the Difference Between the Center of Mass of the Building and the Center of Stiffness of Isolation Layer (건물의 질량중심과 면진층의 강성중심 차이에 따른 면진효과)

  • Hur, Moo-Won;Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.107-115
    • /
    • 2014
  • In this study, we examined the seismic isolation effects due to the difference between the center of mass of the building and the center of stiffness of isolation layer. Because the base isolation technique is a technique that is highly dependent on the performance of seismic isolation devices installed on the seismic isolation layer, we have to examine the horizontal stiffness of seismic isolation devices after making them. If difference between the design stiffness and the actual stiffness of the seismic isolation device occurred, a big problem may be generated in the upper members on the seismic isolation layer. The analytical results show that the more eccentricity increases, the more maximum response acceleration, story shear and the member forces of the upper part of the structure increases, and the damage is expected to be in excess. Therefore, it is recommended that if possible, isolation devices have to be designed to coincide the center of mass of the building with the center of stiffness of isolation layer. If not after making isolation devices, they need to be relocated to prevent the eccentricity.

Investigation of Optimal Outrigger Location of High-rise Offset Outrigger System (초고층 오프셋 아웃리거 구조시스템의 최적 아웃리거 위치에 대한 탐색)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.16-24
    • /
    • 2017
  • The purpose of this paper is to search the optimal location of offset outrigger system in high-rise building after a structural schematic design of 80 stories building was conducted, making use of MIDAS-Gen. In this research, the key factors of analysis study were column stiffness, outrigger position in plan and outrigger location in height. For the aim of finding out the optimum position of offset outrigger system in tall building, we studied the lateral displacement in top floor which is the very essential variables in the structural design of high-rise building. The results of study showed that the column stiffness, the outrigger location in plan and outrigger location in height had an effect on the optimal position of outrigger system. Also, it is indicated that the research results can be useful in acquiring the structural design materials for seeking the optimum position of offset outrigger system in tall building.