• 제목/요약/키워드: 수평평활관

검색결과 14건 처리시간 0.018초

수평 평활관에서 관직경 및 표면 과냉도가 R1234ze(E) 및 R1233zd(E) 막응축 열전달에 미치는 영향 (Effects of Tube Diameter and Surface Sub-Cooling Temperature on R1234ze(E) and R1233zd(E) Film Condensation Heat Transfer Characteristics in Smooth Horizontal Laboratory Tubes)

  • 전동순;고지운;김선창
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.231-238
    • /
    • 2017
  • HFO refrigerants have recently come to be regarded as promising alternatives to R134a for use in turbo chillers. This study provides results from experiments evaluating the film condensation heat transfer characteristics of HFO refrigerants R1234ze(E) and R1233zd(E) on smooth horizontal laboratory tubes. The experiments were conducted at a saturation vapor temperature of $38.0^{\circ}C$ with surface sub-cooling temperatures in the range of $3{\sim}15^{\circ}C$. We observe that the film condensation heat transfer coefficient decreases as surface sub-cooling temperatures increase. In the case of laboratory tubes with a diameter of 19.05 mm, the film condensation heat transfer coefficients of R1234ze(E) and R1233zd(E) were approximately 11% and 20% lower than those of R134a, respectively. Furthermore, our investigation of the effect of tube diameter on film condensation heat transfer coefficients, demonstrates an inverse relationship where the film condensation heat transfer coefficient increases as laboratory tube diameter decreases. We propose experimental correlations of Nusselt number for R1234ze(E) and R1233zd(E), which yield a ${\pm}20%$ error band.

주물사 재생 유동층내 폐열회수 증진에 관한 실험적 연구 (An Experimental Study on the Promotion of the Waste-Heat Recovery in the Fluidized Beds used in Reclamation of Foundry Sand)

  • 백고길;박종순;이은표;최승일;최국광;전성택
    • 태양에너지
    • /
    • 제18권2호
    • /
    • pp.145-152
    • /
    • 1998
  • 본 연구는 furan 주물사의 재생시 냉각효율을 크게 높이며 폐열의 회수를 증진하는 데 활용할 수 있는 자료들을 얻기 위하여, 재생된 Furan foundry sand를 유동입자로 사용한 유동층에서 평활관(smooth tube), 나선관(spiral tube) 및 핀관(finned tube)을 수평으로 설치하여, 유동층 내 온도를 $50{\sim}200^{\circ}C$로 유지하면서 전열 관에 대한 열 전달계수를 실험적으로 구하였다. 유동층의 내경은 210mm이고, 전열관의 외경은 모두 12.7mm인 동관을 각각 사용하였다. 본 실험은 관내 냉각수의 Reynolds수 $4,000{\sim}18,000$범위이고, 유동층내 유동입자 Reynolds수 $0.8{\sim}7.5$의 범위에서 수행하여 다음과 같은 결과들을 얻었다. 1. 유동층내 온도가 높으면 모든 전열관에서 열 전달계수는 커진다. 2. 최대 열 전달계수는 평활관에서는 $Re_p$$3.5{\sim}5.5$, 나선관에서는 $Re_p$$4.4{\sim}5.2$, 핀관에서는 $Re_p$$3.5{\sim}4.8$의 범위에서 각각 얻을 수 있다. 3. 유동층내의 온도에 따라 약간 다르지만 평활관, 나선관 및 핀관에서의 최대 Nu수들은 각각 대략 1:1.5:3.0의 비를 얻는다.

  • PDF

수평원관 내 CO2 R-22 및 R-134a의 증발열전달 특성에 관한 실험적 연구 (Evaporation Heat Transfer Characteristics of CO2 R-22 and R-134a in a Horizontal Smooth Tube)

  • 윤린;황준현;최영돈;김용찬
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.911-918
    • /
    • 2002
  • Evaporation heat transfer coefficients of carbon dioxide($CO_2$), R-22, and R-134a in a horizontal smooth tube were measured and analyzed as a function of heat flux, mass flux, and evaporating temperature. The experiments were carried out by varying heat flux from 10 to 20 $kW/m^2$, mass flux from 170 to 340 $kg/m^2s$, and saturation temperatures of 5 and $10^{\circ}C$. It was found that the heat transfer coefficient of $CO_2$ decreased with a rise of quality due to an earlier liquid-film dryout as compared to R-22 and R-134a. Averaged heat transfer coefficients of $CO_2$ were 22-63% higher than those of R-22 and R-134a at all test conditions. The effects of mass flux and heat flux on averaged heat transfer coefficients were much greater in $CO_2$ than in R-22 and R-134a. When comparing $CO_2$ test results with the correlations in the literature, the existing models yielded large deviations at medium and high qualities. Therefore, a generalized correlation for $CO_2$evaporation heat transfer needs to be developed by including the effects of dryout phenomenon.

평활관에서 이산화탄소의 증발열전달 특성에 관한 실험연구 (Experimental Study on Characteristics of Evaporation Heat Transfer of CO2 in a Smooth Tube)

  • 이상재;최준영;이재헌;권영철
    • 에너지공학
    • /
    • 제16권4호
    • /
    • pp.181-186
    • /
    • 2007
  • 본 연구에서는 이산화탄소의 증발열전달 특성을 이해하기 위해 질량유속, 열유속 기리고 포화온도를 변화시키면서 이산화탄소의 증발 열전달계수와 압력강하를 측정하였다. 질량유속과 열유속은 기존의 실험범위보다 크게 확장하여 내경 7.75 mm, 길이 5.0 m의 수평관에서 실험하였다. 실험장치는 시험부, 전원공급기, 히터, 칠러, 기어펌프, 유량계, 계측시스템 등으로 구성되었다. 건도가 증가할수록 증발 열전달계수는 감소하였으며, 이산화탄소의 증발 열전달계수는 질량유속보다 열유속에 더 민감함을 확인하였다. 또한 주어진 열유속과 포화온도에 따라 증발 열전달계수의 급격한 감소가 다르게 관찰되었다. 압력강하는 질량유속 증가에 대해 선형적인 증가를 보였지만 열유속 증가에 대한 압력강하의 증가효과가 크지 않았다.