• Title/Summary/Keyword: 수평막

Search Result 100, Processing Time 0.031 seconds

Effects of Tube Diameter and Surface Sub-Cooling Temperature on R1234ze(E) and R1233zd(E) Film Condensation Heat Transfer Characteristics in Smooth Horizontal Laboratory Tubes (수평 평활관에서 관직경 및 표면 과냉도가 R1234ze(E) 및 R1233zd(E) 막응축 열전달에 미치는 영향)

  • Jeon, Dong-Soon;Ko, Ji-Woon;Kim, Seon-Chang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.5
    • /
    • pp.231-238
    • /
    • 2017
  • HFO refrigerants have recently come to be regarded as promising alternatives to R134a for use in turbo chillers. This study provides results from experiments evaluating the film condensation heat transfer characteristics of HFO refrigerants R1234ze(E) and R1233zd(E) on smooth horizontal laboratory tubes. The experiments were conducted at a saturation vapor temperature of $38.0^{\circ}C$ with surface sub-cooling temperatures in the range of $3{\sim}15^{\circ}C$. We observe that the film condensation heat transfer coefficient decreases as surface sub-cooling temperatures increase. In the case of laboratory tubes with a diameter of 19.05 mm, the film condensation heat transfer coefficients of R1234ze(E) and R1233zd(E) were approximately 11% and 20% lower than those of R134a, respectively. Furthermore, our investigation of the effect of tube diameter on film condensation heat transfer coefficients, demonstrates an inverse relationship where the film condensation heat transfer coefficient increases as laboratory tube diameter decreases. We propose experimental correlations of Nusselt number for R1234ze(E) and R1233zd(E), which yield a ${\pm}20%$ error band.

The differences of tear film for young Korean of a day indoor space (실내 공간 내에서 한국인 청년의 하루 중 눈물층 변화)

  • Oh, Hyun Jin;Lee, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.535-540
    • /
    • 2012
  • This study is to research the differences of tear film for young people in of a day in a restricted indoor space. The subjects are 58 eyes volunteers for twice preliminary inspection and tear test of a day. 58 healthy individuals with no eye disease, no body disease, orthophoria, corrective visual acuity more than 0.8, binocular spherical equivalence difference over 0.50 diopter, the flattest corneal curvature in horizontal meridian and the steepest corneal curvature in vertical meridian were tested. The uncorrective visual acuity, refractive error, corneal curvature, schirmer test and tear break up test were performed in the morning and afternoon. Schirmer test were $16.0{\pm}7.0mm$ in the morning and $14.1{\pm}7.1mm$ in the afternoon. TBUT were $11.3{\pm}0.6$ sec in the morning and $12.1{\pm}0.9$ sec in the afternoon. They have no significant differences.

Electro-optical characteristic analysis of liquid crystal cell using UV-treated self assembled monolayer (UV 처리된 자기 조립 단분자막을 사용한 액정 셀의 전기광학특성 분석)

  • Chan-Woo Oh;Hong-Gyu Park
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • In this paper, we demonstrated the orientation characteristics of liquid crystals using UV-treated FSAM as alignment layer. Moreover we confirmed the FSAM properties before and after UV treatment on indium tin oxide (ITO) glass substrates using physicochemical analysis. The hydrophobic property of the FSAM surface is change to hydrophilic through UV treatment. After UV treatment the LC molecules also were uniformly and horizontally aligned on the FSAM surfaces and the pretilt angle was obviously changed 90° degrees to 0° degrees. EO characteristic of TN cell which was fabricated with UV-treated FSAM was faster response time compare to conventional PI layer. The FSAM before and after UV treatment has a superior application potential as the LC alignment layer for LCD, potentially replacing the conventional polyimide layer.

Immunohistochemical Study on the Nerve Growth Factor receptors in the Basal forebrain Nuclei of the Postnatal and the adult Rats (출생후 발생단계와 성체의 흰쥐 전뇌 기저부 여러 핵들에서 신경성장인자수용체에 대한 면엮조직화학적 연구)

  • 정영화;홍영고고연영
    • The Korean Journal of Zoology
    • /
    • v.37 no.3
    • /
    • pp.385-408
    • /
    • 1994
  • 출생후 0일. 7일. 14일 및 21일 그리고 성체의 흰쥐 전뇌 기저부의 내측중격핵, 수직 및 수평 대각 Broca대 거대세포 시삭전핵 그리고 복부담창구에서 신경성장인자수용체 (nerv-growth 배ctor receptor, NGFr)에 면역반응을 보이는 신경조직과 세포의 분화를 면역조직화학적 및 전자현미경적 방법을 이용하여 조사하였다. 출생후 초기와 성체에서 신경세포 원형질막 뿐만 아니라 세포질에서 NGFr 면역반응이 확인되었다. 그러나 성체에서 신경세포 원형질 막에서의 면역반응은 관찰되지 않았다. 특히 NGFr 면역반응은 골지 부위에서 보였고, 점상의 면역반응물들이 세포체의 세포질과 수상돌기에 소수 분산 분포하였다. 뇌 기저부의 NGFr 면역반응 신경세포들은 뇌 크기의 증대와 뇌 조직의 분화에 따라 점차 수적 증가를 보였다. 이 NGFr 면역반응 신경세포들은 세포의 모양과 세포체의 장 .단축의 비에 따라 6가지 형. 즉 1) 원형. 2) 타원형. 3) 세장형, 4) 방추형, 5) 삼각형, 6) 다각형으로 분류되었다. 전뇌 기저 핵에서 원형과 난형신경세포들의 출현율은 출생후 0일에서 높았으나 성체로 되면서 감소된 반면, 세장형. 방추형, 삼각형 그리고 다각형신경세포들의 출현율은 출생후 0일에서는 낮았으나 성체로 되면서 증가하였다. 모든 핵들에서 NGFr 면역반응 신경세포체의 부피는 출생후 0일에 759-1,640 Um3로 제일 작았으며, 수직 대각 Broca대와 복부담창구에서는 출생후 14일에 각각 5 107 7.385 Um3 그리고 내측중격핵, 수평 대각 Broca대, 거대세포 시삭전핵에서는 출생후 21일에 각각 4,705, 6,061, 6,412 Um3로 최대치를 보였다. 그후 성체로 되면서 모든 핵에서 1,893-3,464 $\mu$m3로 다시 감소하였다. 전자현미경적 관찰에서 출생후 21일된 흰쥐 수평 대각 Broca대에서 NGFr 면역반응은 세포체와 수상돌기의 원형질막 그리고 세포체내에서는 골지체, 다소포성소체 및 조면소포체에서 관찰되었다. 이 결과들로 미루어 NGFr은 출생후 발생단계와 성체의 횐쥐 전뇌 기저부에서 신경세포의 분화와 분포에 관계되는 것으로 생각된다.

  • PDF

Analysis on Improving Power of Thermal Radiation Shield in Low Pressure Chamber of AMTEC (AMTEC내 저압용기에서의 열복사차단막 형상에 따른 발전량 향상 해석)

  • Chung, Won-Sik;Chi, Ri-Guang;Lee, Wook-Hyun;Lee, Kye-Bock;Rhi, Seok-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.54-62
    • /
    • 2016
  • The most efficient system for converting heat to electricity, AMTEC (Alkali Metal Thermal-to-Electric Convertor), is a device that directly converts heat energy to electricity using an alkali metal (sodium) as the working fluid. The AMTEC consists of a low pressure chamber, high pressure chamber, BASE (Beta-Alumina Solid Electrolyte), and artery wick. The main heat loss of the AMTEC system occurs in the low pressure chamber. A high power generation rate is thought to be obtainable by using a high temperature in the BASE. Therefore, to reduce the radiation heat loss, 6 types of radiation shields were examined to reduce the radiative heat loss in the low pressure chamber. The power generation rate of the AMTEC varied depending on the shape of the radiation shield. CFD (Computational Fluid Dynamics) analyses were carried out to optimize the shape of the radiation shield. As a result, the optimum radiation shield was found to consist of a curvature formed at the vertical point, in which case the dimensionless temperature (condenser temperature/BASE temperature) is approximately 0.665 and the maximum power generated is calculated to be 17.69W. Increasing the distance beween the BASE and condenser leads to an increase in the power generated, and the power generated with the longest distance was 17.58 W. The shields with multiple holes and multiple horizontal layers showed power reduction rates of 0.91 W and 2.06 W, respectively.

Experimental Study on the Heat Transfer Characteristics on a Film-Cooled Flat Plate - Effect of Injection Angle and Blowing Rate - (막냉각되는 평판에서의 열전달특성에 관한 실험적 연구)

  • 이상우;신세현;이택시;이준식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1415-1427
    • /
    • 1988
  • The effect of injection angle and blowing rate on a film-cooled flat plate has been investigated experimentally. Three cases of 90.deg. injection, 35.deg. streamwise injection and 35.deg. spanwise injection are employed. The naphthalene sublimation technique in used to obtain local mass transfer coefficients. Thus heat transfer coefficients are evaluated using heat-mass transfer analogy. Schlieren photographs are taken to visualize the trajectory of injection fluid by introducing carbon dioxide gas through injection tubes. The experiments indicate that due to the injection the heat transfer coefficients increase significantly in the neighborhood of the infection holes, so the design of film cooled component must be based on the heat transfer coefficient with injection as well as film cooling effectiveness.

A Study on the Treatment of Suitable Flame Retardant to the Fibers for Welding Blanket Development (용접 불티 차단막 개발을 위한 섬유류의 적정 방염처리 방안 연구)

  • 이근원;김관응;이두형
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.48-55
    • /
    • 2002
  • This study presents a treatment of suitable flame retardant through evaluating fire performance after treating flame retardant of fibers for development of welding blanket. The experimental samples used were commercial fibers and we are treated fibers with the flame retardant liquid and the flame retardant paint. The fire performance of the sample was carried out according to the Korea and Japan Standard. As the results of the fire performance experiment, the treated fiber in samples had enough in the performance of flame and fire retardant and the grade of their was from grade A to grade C according to flame and fire retardant standard. The lower oxygen index indicated that all treated samples with the resist are satisfied with international standard. We con-sider that the welding blanket treated with grade A, B and C performance prevents fire spread regardless of the height of work stairs in the case of installation horizontally. Also, it is considered that the welding blanket treated with grade C performance prevents fire spread regardless of the height of work stairs in the case of installation vertically.

Studies of Liquid Crystal Alignment on the Photosensitive Polyvinylfluorocinnamate (광감성 폴리비닐플루오로신나메이트의 액정 배향에 관한 연구)

  • Kim, Dong-Soo;Ahn, Won-Sool;Ha, Ki-Ryong;Buluy, O.;Reznikov, Yu.
    • Polymer(Korea)
    • /
    • v.31 no.5
    • /
    • pp.393-398
    • /
    • 2007
  • We studied the mechanism of liquid crystal alignment on polyvinylfluorocinnamate (PVCN-F) films which were irradiated by UV using polarized fourier transform infrared (FT-IR) spectroscopy and ultraviolet/visible (UV/Vis) spectroscopy. UV irradiation of PVCN-F films caused decrease of vinylene -C=C- stretching peak area at $1638cm^{-1}$ and shift of conjugated C:0 stretching vibration at $1712cm^{-1}\;to\;1734cm^{-1}$ which is caused by nonconjugated C=O stretching nitration. To study the orientation direction of 5CB liquid crystal (LC) molecules in the liquid crystal cell with PUV irradiation, rubbing treatment or without any treatment on the PVCN-F alignment layer, we used polarized FT-IR dichroism technique. We successfully measured 5CB LC alignment directions, which are perpendicular to the irradiated PUV polarization direction and parallel to the rubbing direction in the liquid crystal cell without using dichroic dyes.

THE INVESTIGATION OF MICROVASCULATURE CHANGES IN OSSEOUS REGENERATION BY GUIDED TISSUE REGENERATION PROCEDURE (골재생유도술에 의한 골재생시 미세혈관 구축 양상)

  • Choi, Du-Hee;Ryoo, Hyun-Mo;Shin, Hong-In
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.3
    • /
    • pp.257-265
    • /
    • 1999
  • To investigate the sequential changes in microvascular architecture and osseous regeneration during the bony healing after an application of the guided tissue regeneration method, we made artificial defects measuring $0.7cm{\times}0.3cm$ in size on femoral bones of rats measuring about 200gm and applied non-absorbable TEFE membrane at experimental sites but not at control sites. Then we observed the sequential changes and correlations between new vacuolation and bony regeneration using microvascular corrosion cast method and routine light microscopic observation at 1, 2 and 3 weeks after operation, respectively. The results showed that there were close relationships between regeneration of microvasculature and bone. In early phase, the invasion of granulation tissue at control sites delayed bony regeneration, however, in later phase, there was no remarkable differences in bony regeneration between control and experimental sites. The placement of barrier also affected in revascularization of regenerating bony defects. This is, the experimental sites showed parallel arranged nutritional vessels along long axis with well developed retiform plexus whereas the control revealed vertical invasion of microvasculature from outside of marrow space through bony defects which was also rearrange with time into parallel pattern with a vertical plexus but lesser organized than that of experimental sites. These findings suggest that the reconstruction of regenerating vasculature within the marrow cavity only may be sufficient and/or more be efficient in regeneration of bony defects.

  • PDF

Pervaporation Separation of fluoroethanol/water Mixtures through Crosslinked Poly(vinyl alcohol) Composite Membranes (가교된 폴리비닐알콜 복합막을 이용한 불화에탄올/물 혼합용액의 투과증발분리 특성)

  • 이수복;안상만;장봉준;김정훈;이용택
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.166-172
    • /
    • 2004
  • As a preliminary study for esterification membrane reactor used to produce 2,2,2-trifluoroethylmetacrylate (TFEMA), Pervaporation behaviors with crosslinked Poly(vinyl alcohol) composite membranes were investigated for aqueous TFEA (2,2,2-trifluoroethanol) feed solutions. In this study, crosslinked PVA composite membranes were prepared by reacting PVA with glutaraldehyde (CA)/acid catalyst onto porous polyethersulfone (PES) supports. SEH images (scanning electron microscopy) showed the thicknesses of selective coating layer was about 2-3 ${\mu}{\textrm}{m}$. The swelling tests showed the dogree of crosslinking decreased as content of the crosslinking agent, GA, increased. Total permeation flux decreased while separation factor increased as the CA content increased. As operating temperature increased, total permeation flux remarkably increased in the range of 85-95 wt% TFEA aqueous solutions. Interestingly, however, separation factor decreased in 85-90 wt% with operating temperature, while that increased in 95 wt%. In case of 90 wt% TFEA concentration and operating temperature 8$0^{\circ}C$, the PVA composite membrane crosslinked with 0.1 mol GA per PVA repeating unit showed high permeation flux of 1.5 kg/$m^2$hr and separation factor of 320. These results confirmed the applicability of the PVA composite membranes for the esterification membrane reactor of TFEMA.