• Title/Summary/Keyword: 수평관

Search Result 295, Processing Time 0.021 seconds

Influence of Vapor Phase Turbulent Stress to the Onset of Slugging in a Horizontal Pipe (기체상의 난류 응력이 수평 유동관 내에서의 Slugging에 미치는 영향에 관한 연구)

  • Park, Jee-Won
    • Nuclear Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • In influence of the vapor phase turbulent stress (i.e., the too-phase Reynolds stress) to the characteristics of two-phase system in a horizontal pipe has been theoretically investigated. The average two-fluid model has been constituted with closure relations for stratified flow in a horizontal pipe. A vapor phase turbulent stress model for the regular interface geometry has been included. It is found that the second order waves propagate in opposite direction with almost the same speed in the moving frame of reference of the liquid phase velocity. Using the well-posedness limit of the two-phase system, the dispersed-stratified How regime boundary has been modeled. Two-phase Froude number has been found to be a convenient parameter in quantifying the onset of slugging as a function of the global void fraction. The influence of the taper phase turbulent stress was found to stabilize the flow stratification.

  • PDF

표준원전 모의 열수력 종합실험장치의 개념설계 및 저온관 소형냉각재상실사고 예비해석

  • 배규환;문상기;박춘경;권태순;송철화;양선규;정문기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.699-706
    • /
    • 1998
  • 한국원자력연구소에서는 원자력중장기연구의 일환으로 한국형 표준원전을 모의하는 종합열수력실증실험을 계획하고 있으며, 현재 실험장치에 대한 척도해석(Scaling Analysis), 예비해석(Scoping Analysis) 및 개념설계를 수행하고 있다. 본 논문에서는 영광 3/4호기를 대상으로 척도해석을 통하여 실험장치를 개념설계하고, 저온관 6인치 소형냉각재 상실사고에 대하여 예비해석을 수행한 결과를 보여준다. 개념설계된 실험장치는 높이비가 참조원자로와 동일하고, 체적비가 1/200이다. 실험장치의 개념설계는 이상유동에 대한 3단계 척도법을 적용하였으며, 개념설계의 타당성을 입증하기 위해 RELAP5/MOD3.1 코드를 사용하여 정상상태 및 저온관 6인치 소형냉각재 상실사고시 계통의 거동을 예비 계산하였다. 실험장치에 대한 예비해석결과 사고 거동이 참조원자로와 잘 일치하는 것으로 나타났다. 또한 수평관 및 주냉각재펌프의 척도기준이 사고의 진행과정에 영향을 미치는 중요한 인자로 밝혀졌다

  • PDF

Effects of Conductivity and Thickness on Natural Convection Heat Transfer From a Horizontal Circular Tube (수평 원통관의 열전도율과 두께가 자연대류 열전달에 미치는 영향)

  • 정영식;강병희;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.265-279
    • /
    • 1986
  • Ra=$10^{6}$, Pr=5에서 관열전도율과 두께가 변화할 때의 단일수평관에서의 자연대류 열전달에 관하여 유한차분법을 이용하여 해석적으로 연구하였다. .delta.$_{w}$ /d$_{o}$ =0.1에서 관열전도율이 높을수록 높은 온도와 높은 국소 누셀트 수를 나타 내며, .theta.=20。에서의 원주방향속도는 (r-r$_{o}$ )=0.08에서 최대가 되며 반경방향속 도는 (r-r$_{o}$ )=0.14에서 최대가 된다. 관외벽온도는 관 두께가 증가함에 따라 거의 유사하게 감소한다. $K_{w}$ /K$_{f}$ =75에서 각도변위가 증가함게 따라 국소 누셀트수는 현저히 증가하나 관 두께가 증가함에 따라서는 감소한다. .delta.$_{w}$ / d$_{o}$ =0.1에서 평균 누셀트수와 평균 온도는 무차원 열전도율이 증가함에 따라 $K_{w}$ /K$_{f}$ >15에서는 평균 누셀트 수는 서서히 증가하고 평균 온도는 거의 같 은 값을 가지며 지수함수로 표시할 수 있었다. $K_{w}$ /K$_{f}$ =75,50에서 평균 누 셀트수와 온도는 무차원 관 두께가 증가함에 따라 거의 직선적으로 감소되며 선형 함 수로 나타낼 수 있었다.

Agricultural Radial Collector Wells in South Korea and Sustainability (한국의 농업용 방사상 집수정 현황 및 지속가능성)

  • Hong, Soun-Ouk;Song, Sung-Ho;An, Jung-Gi;Kim, Jin-Sung
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.331-337
    • /
    • 2016
  • Radial collector wells (RCWs) have been managed by Korea Rural Community Corporation (KRC) since 1983, installing 98 wells for agriculture in rural area over the country. Among them, 20 wells were installed upstream of 5 subsurface dams and the remaining were installed regardless of the subsurface dam. Most of RCWs have been developed in 1980s and 1990s, and 83 wells have been passed more than 20 years after construction. The number of horizontal arms for RCWs varies from 9 to 28, with length and diameter being 10~30 m and 65 mm, respectively. The central caisson with an inner diameter of 3.5 m was commonly constructed to a depth of 10 m. The maximum pumping rates in RCWs, which are located at distances of 10 to 1,200 m from the river, are 2,000~10,000 m3/day. RCW has a fundamental problem that reduced pumping capacity and degraded well efficiency, due to the physical and chemical clogging. From the feasibility test for improving RCW performance, specific capacity increased to 67% after rehabilitation. TV logging for RCW horizontal arm shows that near the caisson is more severe clogging. From the results of this study, KRC has established the guidebook for monitoring and improving well efficiency through physical/chemical treatment, well logging, and hydraulic tests and managed RCWs periodically with its rehabilitation methods.

Experimental Distillation of Ethanol-Propanol Mixture Using a Horizontal Column (수평증류를 이용한 에탄올-프로판올 혼합물의 증류실험)

  • Kim, Byoung Chul;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.93-97
    • /
    • 2013
  • A lab-sized distillation experiment was conducted using small-size packings and a horizontal distillation column. The 6.7 mm Raschig ring type packings of stainless steel and a 40 mm glass column were used, and five independent electric heaters were installed in the axial direction to adjust the column inside temperature separately. The temperature was continuously distributed along the column length to provide equivalent equilibrium to the temperature for the separation. From the experimental results, a larger HETP of the column than the vertical distillation column was obtained, but it was found that the practical separation with proper processing capacity and separation efficiency was available.

A Semi-Empirical Correlation for an Adiabatic Interfacial Friction Factor (단열 계면 마찰계수에 대한 준 실험식)

  • Nam, Ho-Yun;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.108-118
    • /
    • 1994
  • A semi-empirical correlation has been developed for adiabatic interfacial friction factors in a long horizontal air-water countercurrent stratified flow conditions. Using a pipe and duct test sections, a series of experiments hate been conducted varying non-dimensional water depth and flow rates of air. On the basis of simultaneous measurement of the main flow parameters in a horizontal pipe and a duct, a semi-empirical correlation for the interfacial friction factor in a stratified flow regime has been developed employing a new concept of surface roughness in wavy flow. A total of 201 data point, including 15 concurrent pipe flow test data of others, have been used in the present analysis. A comparison between the data and the predictions of the present correlation shows that the agreement is within $\pm$30%.

  • PDF

FEA and Model test of Backfill Materials for Underground Facility with Recycling Materials (재활용 재료를 이용한 지하 매설물용 뒤채움재의 모형시험 및 유한요소해석)

  • Lee, Kwan Ho;Kim, Sung Kyum
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.177-177
    • /
    • 2011
  • 현재 대부분 사용되는 지하매설물용 뒤채움재는 다짐공법을 많이 사용하고 있으며, 실제로 이러한 방법은 부적절한 다짐으로 인해 침하 및 내구성 저하로 인해 파손을 초래하는 경우가 많다. 이러한 문제를 해결 할 수 있는 하나의 대안으로 유동성 뒤채움재를 이용할 수 있다. 유동성 뒤채움재는 초기 유동성, 시간에 따른 자기 강도 발현 무다짐공법 적용 등 많은 장점을 가지고 있다. 본 연구에서는 현장발생토사, 정수장슬러지 및 폐타이어분말 등 재활용 재료를 이용한 유동성 뒤채움재의 기본물성을 평가하였다. 각각의 재활용재료에 대한 입도 및 비중을 평가하였고, 최적배합설계를 결정하였으며, 모형 시험과 유한요소 해석을 위한 기본 물성값을 위해 일축압축시험, 삼축압축시험, 공진주시험 등을 수행하였다. 최적배합설계를 산정하는 과정에서 수행한 실험중 대표적인 시험으로 자가수평능력 및 자기다짐등에 필요한 유동성을 판단하는 Flow시험(ASTM D 6133) 결과 기준으로 정한 20cm이상의 값을 얻을 수 있었으며 일축압축강도의 경우 시공 후 유지 보수가 용이한 강도인 $3.0kg/cm^2{\sim}5.6kg/cm^2$이하로 설계하였으며 28일재령 일축압축강도 결과 $3.15{\sim}3.74kg/cm^2$라는 유지보수에 적당한 결과값을 나타내었다. 이 배합이 현장에서 사용이 가능하다는 것으로 판단하고 현장모형시험과 유한요소해석를 통하여 현장에서 사용하였을 때 관의 변형과 관에 작용하는 하중변화를 확인하고 현장모형시험과 유한요소해석 간의 상관관계를 규명하였다. 현장 모형 시험은 현장과 비슷하게 제작된 모형을 이용하였으며 최대한 현장과 비슷한 조건에서 뒤채움재를 타설과정 중과 타설이 완료된 상태에서 7일 양생 후 하중재하와 같이 두가지 경우에서 수직 수평토압, 관의 수직 수평변위, 관의 종단변형을 측정하였다. 유한요소해석 프로그램은 Midas GTS를 이용하여 실시하였으며 관의 변형률, 유효응력을 측정하여 규명하였다.

  • PDF

Cooling Heat Transfer Characteristics of Carbon Dioxide in a Horizontal and Helically Coiled Tube (수평관과 헬리컬 코일관내 이산화탄소의 냉각 열전달 특성)

  • Son, Chang-Hyo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.121-126
    • /
    • 2008
  • The cooling heat transfer coefficient of $CO_2$ (R-744) in a horizontal and helically coiled tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater, evaporator and gas cooler (test section). The test section consists of a horizontal stainless steel tube and hellically coiled copper tube of 4.57 and 7.75 mm. The experiments were conducted at saturation temperature of 100 to $20^{\circ}C$, and mass flux of 200 to $500kg/m^2s$. The test results showed the variation of the heat transfer coefficient tended to decrease as cooling pressure of $CO_2$ increased. The heat transfer coefficient with respect to mass flux increased as mass flux increased. The experimental results were also compared with the existing correlations for the supercritical heat transfer coefficient, which generally underpredicted the measured data. However, the experimental data showed a relatively good agreement with the correlations of Pitla et al. except for the pseudo critical temperature.