• Title/Summary/Keyword: 수평관

Search Result 295, Processing Time 0.027 seconds

Comparative Studies on Heating and Cooling Loads' of a Building Varied by Annual Weather Data (연도별 기상데이터를 활용한 건물의 냉.난방부하 특성 비교)

  • Lee, Ji-Hoon;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.35 no.3
    • /
    • pp.265-270
    • /
    • 2011
  • The purpose of this study is to compare and analyze the differences of a building's heating and cooling loads depending on the weather variation. Followings are the results. The temperature, humidity and wind speeds of standard year are bigger than those of 2006~2009. The 2006~2009's total horizontal solar irradiance is greater than that of standard year, and the direct solar irradiance of standard year is bigger in winter and vice versa in summer. As results of simulation on heating and cooling loads, it is difficult to find out the bilateral influences between maximum thermal loads and annual's. The equivalent-time operating ratio(EOR) is defined on this study to estimate the differences between year and year, and the EOR of standard year shows low value comparing to 2006~2009 years'.

Palm Area Detection by Maximum Hand Width (손 최장너비 기반 손바닥 영역 검출)

  • Choi, Eun Chang;Kim, Jun Yeon;Lee, Jae Won;Lim, Jong Gwan
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.4
    • /
    • pp.398-405
    • /
    • 2018
  • In the HCI, hand gesture recognition is attracting attention as a method for interaction and information exchange between users and devices along with the development of IT devices. In hand gesture recognition through image processing, palm region detection is a key process contributing to improvement of processing speed and recognition rate. In this paper, we propose a new method for image segmentation between the hand and wrist for palm area detection. The anatomical characteristics of the hand are used to calculate the distance between the iliac bones of the thumb and little finger, which have the widest width, by the horizontal projection histogram of the hand image, and then the palm area is detected by drawing a circle having the width as the diameter. In order to verify the superiority of this method, multiple stage template matching is used to compare and evaluate recognition performance against the four conventional methods for 10 hand gestures. Note that the literatures to offer palm area detection performance evaluation are few although there are many studies on hand gesture recognition.

A Study on Process Design of Hot Oil Flushing System Using Oil-Nitrogen Gas Mixing Fluid (오일-질소가스 혼합유체를 이용한 고온 오일플러싱 시스템 공정설계에 관한 연구)

  • Lee, Yoon-Ho;Choi, Bu-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.541-548
    • /
    • 2017
  • A theoretical study on gas-liquid two-phase flow flushing systemnitrogen gas to the oil used for existing flushing equipment was conducted on the basis of ISO code so as to improve performance of existing high-temperature oil flushing equipment used in ocean plant facility drying field. For study, we analyzed process simulation results mixed fluid mixing ratio, temperature, Reynolds number and liquid hold up affectcleaning performance after designing oil-nitrogen gas mixture flushing system process. As a result, as the volume flow rate of mixed fluid increases with the tube diameter the volume fraction of the gas phase constant, the liquid fraction difference value at the inlet and outlet of horizontal hydraulic piping increases. It was found that the phase distribution between oil and nitrogen gas bubbles varies depending on the position the pipe lengthdirection. This change in phase distribution is expected to have a significant impact on the clean performance of an oil-nitrogen gas mixture flushing system.

Random Vibration and Harmonic Response Analyses of Upper Guide Structure Assembly to Flow Induced Loads (유체유발하중을 받는 상부안내구조물의 랜덤진동 및 조화응답해석)

  • 지용관;이영신
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.59-68
    • /
    • 2002
  • The cylindrical Upper Guide Structure assembly of the reactor intervals wish the Core Support Barrel and the Inner Barrel Assembly is subjected to flow induced loads horizontally which include random pressure fluctuation due to turbulent flow and pump pulsation pressures. The purpose of this papers is to perform random vibration and harmonic response analyses fort flow induced loads. The dynamic response characteristics due to random turbulence and pump pulsation loads were evaluated using the lumped mass beam model. Especially the model considered the annulus effects due to water gaps existing between cylindrical structures such as the Upper Guide Structure Barrel, the Core Support Barrel, and the Inner Barrel Assembly. The effect of the Inner Barrel Assembly inside the Upper Guide Structure assembly was studied. The peak dynamic responses lot each loading condition due to the addition of IBA were affected by the natural frequencies of the structures. Therefore the peak dynamic responses of the structures should be conservatively obtained from evaluation of dynamic analysis for various loading conditions.

A Study on the Detecting Accuracy of EM Induction Survey Data of Buried Utility (전자유도 탐사를 이용한 지하매설물 탐지 정확도 분석)

  • Kwon, Hyoung-Seok;Choi, Joonho;Hwang, Daejin;Kim, Munjae;Yoon, Jeoungseob
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.4
    • /
    • pp.73-81
    • /
    • 2008
  • Electromagnetic induction surveys are one of the useful methods to detect the location and buried depth of underground utilities by measuring horizontal and vertical magnetic fields. It can effectively detects single buried utility with the accuracy of within 20 cm. However when another utility is buried near to target one, the accuracy of utility location considerably decreases due to the distortion of magnetic fields caused from adjacent utility. This study shows the ways to verify the location and buried depth of target utility when magnetic fields does not show symmetric distribution due to adjacent another utility. Using Bluetooth wireless communication tools, we developed the way to records measured magnetic fields to handheld PDA. We investigated the criteria for minimum distance of two adjacent utilities to separate the individual responses through field model test.

  • PDF

Application of Culture Inclusiveness Concept for Hongdae-ap Case (홍대앞 사례를 통한 문화적 포용성 개념의 적용)

  • Park, Minha;Lee, Byungmin
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.539-554
    • /
    • 2019
  • This study suggests a conceptualization model of 'cultural inclusiveness' organically connected to social inclusiveness, by expanding the implications of urban inclusiveness to the domain and relationship. Based on the process of necessity of relation, connection of space, and execution of act, the cultural inclusiveness could be connected to the formation of organic/learning relation, the creation of openness focusing on public space, and the practice of diverse subjects. Concretely, the concept of cultural inclusiveness is applied to the case of 'Hongdae-ap'. The recent Hongdae-ap is showing the value of coexistence such as the establishment of environment that could protect the diversity of individual subjects and groups(artists, residents, government officials, students, cultural activists, citizens, tourists, and etc.), the formation of public space such as 'Hongdae-up playground', 'pedestrian-friendly street', and 'Gyeongui-Line book street', social network service & horizontal network, and access.

Study on enhancement of evaporating heat transfer in narrow horizontal annular crevices (좁은 수평 환형 Crevice에서의 증발열전달촉진에 관한 연구)

  • Bae, Sang-Cheol;Kim, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1481-1490
    • /
    • 1996
  • This study is intend to improve flow pattern within evaporator, which is low quality and low mass flux, by installing narrow horizontal annular crevice so that enhance heat transfer coefficient. The motive, which made to study heat transfer enhancement by using narrow annular crevice, came from capillary phenomena and pumping force of generating vapor on refrigerant boiling. Tests were run about 5 models of turbulence promoter with CFC-12, in the range of evaporating temperature (15.deg. C), mass flux (50 to 100 kg/m$\^$2/s), heat flux (3.4 to 6.7 kW/m$\^$2/), quality (0.1 to O.5). It is observed that flow pattern within evaporator is changed closely to semi-annular flow or annular flow, of which refrigerant liquid is reached to the upper side of tube by using narrow annular crevice. When the narrow annular crevice is installed in the evaporator tube, local heat transfer coefficient is generally more improved than that of smooth tube. That fact is according to observed result of flow pattern. It is learned that narrow annular crevice has more efficiency at a low mass flux. At the TP-5, enhancement of heat transfer rate is about 170% compare to that of smooth tube on a low mass flux (50 kg/m$\^$2/s), and it is about 134% on a high mass flux (100 kg/M$\^$2/S), so that we know that it is on a very high condition.

TREATMENT OF ANTERIOR OPENBITE IN THE GROWING CHILDREN : A CASE REPORT (성장기 아동에서 전치부 개교의 치료증례)

  • Yook, Geun-Young;Choi, Nam-Ki;Kim, Sun-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.236-243
    • /
    • 2005
  • Anterior openbite is defined as the lack of contacts between the functional occluding teeth on vertical line at centric occlusion and classified into functional and skeletal anterior openbite based on its causes and characteristics. In mixed dentition, habit control and the elimination of abnormal perioral muscle function and moving the vertical direction development to the sagittal direction of the mandible by the functional appliance is a goal of treatment. This study presents the effective interception of oral habit by the tongue crib and functional-fixed treatment and treatment response of openbite related to tongue thrust habit.

  • PDF

A Study on the Characteristic of Impinging Pressure Distribution in the Three Dimensional Impinging Water Jet (삼차원(三次元) 수분류(水噴流)의 충돌(衝突) 압력(壓力) 분포(分布) 특성(特性)에 관(關)한 연구(硏究))

  • Lee, J.S.;Choi, K.K.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.217-228
    • /
    • 1998
  • The purpose of this research is to investigate the characteristics of static and total pressure distribution in the upward free water jet system impinged on a downward flat plate. The rectangular nozzle was used and its contraction and aspect ratio was five and about seven respectively. Experimental conditions considered were jet velocity, distance between nozzle and flat plate, height of supplementary water. It was founded that pressure distribution on the flat plate had the Gaussian curve when the pressure at stagnation point and impinging half width were chosen as the scaling parameters. The maximum pressure was shown at the stagnation point. The central impingement velocity decreased with the increment of distance between nozzle and flat plate, and its slop of decay was similar to that of chracteristics decay region in the three-dimensional free jet.

  • PDF

Prediction of Maximum Fly Ash Conveying Capacity of Fly Ash System in a Power Plant (발전 보일러용 비회 이송설비에서 최대 비회 이송량 예측)

  • Jin, Kyung-Yong;Moon, Yoon-Jae;Lee, Jae-Heon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.11 no.1
    • /
    • pp.50-57
    • /
    • 2015
  • This study presents prediction of maximum fly ash conveying capacity of fly ash system in a power plant. The mixture ratio and pressure drop characteristics of air-fly ash flow in piping system are not well understood due to the complexity of particle motion mechanism. In this paper, the researcher investigated the optimum mixture ratio when the pressure drop of fly ash conveying system is equal to maximum static pressure of displacement fly ash transport blower and the capacity of fly ash transport according to the optimum mixture ratio by experimenting the fly ash conveying system of domestic D coal thermal power plants, which is currently in operation. The experiment results showed that the maximum fly ash conveying capacity of fly ash system were founded under the condition of maximum air volume 5,040 m3/h, static pressure of trip condition 1,163 mmH2O. In addition, it was predicted maximum mixture ratio of the air-fly ash was 8.66 and maximum capacity of fly ash conveying was 52,600 kg/h under these conditions.

  • PDF