Combined Convective Heat Transfer from Vertical Parallel Plates (수직 평행평판에서의 혼합대류 열전달)

  • 양성환;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.299-306
    • /
    • 1989
  • The combined convective heat transfer from vertical parallel plates with constant temperature has been studied by numerical method. The governing equations for the system are solved by the finite difference method and successive over relaxation scheme for Re$_{L}$ = 50 - 500, Gr = 10$^{4}$, Pr = 0.7. Results for various plate spacings and plate lengths are as follows ; For various plate spacings, the mean Nusselt number increases and then decreases as the dimensionless plate spacing increases. The optimum plate spacing for maximum mean Nusselt number decreases with increasing Reynolds number and can be expressed as a function of Reynolds number. For various plate lengths, the mean plate Nudest number increases as the dimensionless plate length decreases and Reynolds number increases.

Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition (착상조건하에서 평행 평판 열교환기의 열 및 물질전달)

  • Lee, K.S.;Lee, T.H.;Kim, W.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF