• Title/Summary/Keyword: 수직 보강재

Search Result 89, Processing Time 0.027 seconds

Dynamic stability of anisotropic cylindrical shells (이방성 원통쉘의 동적 안정성)

  • Lu, Sung Y.;Chon, W. Kim
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.3
    • /
    • pp.178-182
    • /
    • 1981
  • 쉘이 복합재로 제작되었거나 보강재를 사용하였을때에는 쉘요소의 역학적 특성은 방향성을 가지게 된다. 이 논문에서는 선형관계식을 사용하여 동적 표면가동을 받는 이방성원통쉘의 안정성을 고려하여 다루었다. 재료의 이방성을 고려하여 3방향 즉, 축방향, 둘레방향 및 반경향의 실성항이 포함된 운동방장실을 유도하였다. 동적 안전성의 해석은 Bolotin 의 방법을 따랐으며 근사해를 행렬식행으로 제시하였다. 수직열로 외압을 받는 원통쉘의 좌단을 다루었으며 본 이론과 고전이론 사이의 차이점을 검토하였다.

Friction Features of Geosynthetics Through the Pullout Test (인발실험을 통한 토목섬유의 마찰특성 평가)

  • Shin, Eun-Chul;Yun, Sock-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.1
    • /
    • pp.3-13
    • /
    • 2003
  • Recently, construction of the reinforced earth structures, which adopts reinforcing materials of geosynthetic, is rapidly increasing due to its good economic advantages, beautiful appearance, and convenient construction. Nonetheless, the most important factor of interpretation and design of the reinforced earth structures, which is assessment ways of friction features between earth and geosynthetic, has not been standardized yet. It has great difference of interpretation and design methods which suggested to the design engineer. This study is to present the way how to assess more reasonably friction features between geogrid and weathered granite soil through the pullout test. Based on a large-scale pullout test of geogrid, the maximum shear stress, interface fricton angle, and friction efficiency are presented with consideration of various test condition.

  • PDF

Evaluation of Strain Distribution and Pullout Strength based on Width and Horizontal Spacing of Geosynthetic Strip (띠형 섬유보강재의 폭과 설치간격에 따른 변형률 분포 및 인발강도 특성 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.2
    • /
    • pp.39-47
    • /
    • 2012
  • This paper describes large-scale pullout test results of geosynthetic strip, which can be applied in reinforced earth wall with block-type wall facing. The pullout tests are conducted to evaluate the strain distribution, the induced pullout force and the pullout strength. The maximum pullout force is appeared regardless of reinforcement width and normal stress when end displacement is less than 15 mm. The pullout behavior based on horizontal spacing of reinforcement was similar in relationship between pullout force and end displacement. The strain distribution and pullout force distribution of the geosynthetic strip are concentrated in the front part of reinforcement, and it appeared clearly in higher normal stress condition This means that the pullout behavior of geosynthetic strip is affected by the bond between soil and friction resistance reinforcement according normal stress. Therefore, the pullout resistance design is reasonable when pullout behavior of geosynthetic strip should be evaluated by effective length considering tensile characteristic.

The Buckling Analysis of Stiffened Opening Plastes with Two Opposite Elastic Supports and Two Other Opposite Simply Supports Subjected to In-Plane Pure Bending (면내휨을 받는 2변단순지지 2변 탄성지지 유공 보강판의 좌굴해석)

  • 김일중;정동조;이용수
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.149-158
    • /
    • 1995
  • When hot-rolled wide flanges are used as vertical compressive or bending member, opening web are often to take a space for equipments of pipe or duct. The Web of hot-rolled wide flange steel with opening may be analyzed as a rectangular plate, subjected to in plane force, and the buckling load is governed by the ultimate force of web. The result of the theory showed close agreement with the result of the finite element analysis. It was also shown that the buckling loads of stiffened opening plates could be larger than those of the plate. The stiffened opening plates for the 4-side simply supported case showed more stiffening effect than the Two Opposite Elastic Supports and Two Other Opposite Simply Supports case. In this study, we proposed the effective opening sizes that buckling loads of stiffened opening plate could be greater than those of the plates.

  • PDF

Mechanical Properties of Three-dimensional Glass Fabric-reinforced Vinyl Ester Matrix Composites (삼차원 유리직물 강화 비닐에스테르 복합재의 기계적 특성)

  • Park, Won-Bae;Park, Soo-Jin;Lee, Jae-Rock
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.715-718
    • /
    • 1998
  • In this work, bisphenol type vinyl ester was impregnated into the three-dimensional glass fabrics fabricated from different thickness changes. Their mechanical properties of the specimens have been investigated by three-point bending and flatwise compression tests. Also, interlaminar shear strength (ILSS) has been determined through short-beam test for the evaluation of interfacial adhesion at interfaces between fibers and matrix of the composites. The effect of thickness changes in three-dimensional glass fabric-reinforced composites have been described in this work.

  • PDF

Vibration Analysis of Stiffened Corrugated Composite Plates (보강된 적층 복합재료 주름판의 진동해석)

  • Park, Kyung-Jo;Kim, Young-Wann
    • Composites Research
    • /
    • v.33 no.6
    • /
    • pp.377-382
    • /
    • 2020
  • The free vibration characteristics of corrugated laminated composite plates with axial stiffeners is investigated using the Rayleigh-Ritz method. The plate is stiffened by beams with open cross-section area. The equivalent homogenization model is used for the corrugated laminated composite plates. This homogenization model is treated a corrugated plate as an orthotropic plate that has different material properties in two perpendicular directions. The motion of equivalent plate is represented on the basis of the first order shear deformation theory (FSDT) to account for the effect of rotary inertia and transverse shear deformation. Stiffeners are considered as discrete elements to predict the local vibration mode to be generated by the presence of stiffeners. To validate the proposed analytical approach, natural frequencies and vibration mode shapes from the analytical method are compared with those from the FEA by ANSYS.

Evaluation on Bearing Capacity of End Girder Member with Local Corrosion (지점부 부재의 부식손상에 따른 강거더 단부 지압강도 평가)

  • Ahn, Jin Hee;Lee, Won Hong;Kim, In Tae;Jeong, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.74-82
    • /
    • 2017
  • Localized corrosions damages in their structural sections can be occurred affected by installed environment conditions with high temperature as near the coastline and humidity or their poor maintenance situation. In bearing supports of steel bridges, especially, lower web and vertical stiffener in end girder support can be easily corroded because of relatively higher humidity due to the narrow space in the end of girder and the wetted accumulated sediments affected by rain water or antifreezing admixture leaked from expansion joint. It can be related to change in their structural performance. In this study, thus, bearing strength test specimens were fabricated considering corrosion damage in the web and vertical stiffeners and the change in their bearing strengths were experimentally evaluated. From the test results, localized corrosion damage of structural members in the end girder affected the bearing strength of end girder support, especially, localized corrosion damage of the vertical stiffener relatively highly affected their bearing strengths.

Stability evaluation of reinforced earth walls based on large-scale modular blocks (대형 축조블록을 이용한 보강토옹벽의 안정성 평가)

  • Han, Jung-Geun;Kim, Min-Woo;Hong, Kikwon;Yun, Jung-Mann
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.143-151
    • /
    • 2014
  • This paper describes external and internal stability of reinforced earth wall using large-scale modular block and geogrid reinforcement. The evaluation for external and internal stability was conducted to analyze effect of wall height, reinforced soil (or backfill soils) and reinforcement strength. The external stability showed that the analysis cases were satisfied with design criteria, when the required minimum length and vertical spacing of reinforcement were 0.7H and 1m, respectively. The internal stability conformed that some cases were satisfied with design criteria in $25^{\circ}$ of internal friction angle of reinforced soil. Expecially, it will be applicable as wall structure considering a structural stability and economic efficiency based on evaluation of internal stability.

Pullout Characteristics of Geogrid with Attached Passive Reinforcement (마찰돌기를 부착한 지오그리드의 인발특성 평가)

  • Moon, Hongduk;Yoo, Chulho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.11
    • /
    • pp.43-51
    • /
    • 2014
  • In this study, a series of pullout experiments were conducted on geogrid with attached passive reinforcement with respect to silt containments. Experiments were performed on man-made sand ground containing different silt of 0 %, 17 %, 35 % under various normal stresses 30 kPa, 60 kPa, 120 kPa respectively. The pullout test results showed that passive reinforcement increased the pullout strength over all silt contained condition and showed up to 20 % increases for same soil condition. The test results converted to the coefficient of interaction of pullout test to investigate the effect of reinforcement and the case of passive reinforcement showed 0.7~1.6 distribution depend on a silt contents. Therefore it is concluded that the overall length of geogrid can be reduced under the low vertical stress conditions.

Behavior of Underground Flexible Pipe According to Ground Characteristics (지반특성에 따른 지중 연성관의 거동특성)

  • Chang, Yongchai;Kim, Yonghyu;Lee, Seungeun;Park, Kichul;No, Jinsuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.41-48
    • /
    • 2009
  • A flexible pipe was buried 10cm below the ground formed with standard sand to observe changes in the shape of the pipe according to the behavior of ground at each relative density. Changes in the shape of the pipe in each ground were observed to examine the behavior of the pipe under the state of reinforced ground after installing geogrid under the pipe. Ground reinforced using geogrid formed tensile force on the reinforcement material with increase in the vertical load and showed reduction in settlement under identical vertical load with existence of reinforcement. Distributions of ground deformation of 100% relative density and 70% relative density had clear difference. Reinforced ground with 70% density converged to the ground reaction of final settlement of non-reinforced ground with 100% density at final settlement of 100 mm. Because the shape of lower part strain of the buried pipe is similar to that of un-reinforced ground with relative density of 100%, reinforcement effect by geogrid in soft ground can be anticipated.

  • PDF