• Title/Summary/Keyword: 수직축 터빈

Search Result 60, Processing Time 0.029 seconds

MPPT and yaw-axis control of parallel type wind turbine (병렬형 풍력 발전시스템의 MPPT 및 yaw축 제어)

  • IM, Jong-Wook;CHOY, Ick
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.250-251
    • /
    • 2010
  • 본 연구는 수평축(horizontal axis) 풍력 터빈에 의해서 수직축 발전기를 운전하는 구조 및 그 운전 방식에 관한 것으로서 바람에 의해 수평축 터빈 로터로 입력된 회전력을 기계적으로 두 개의 수직축 회전 성분으로 변환하여 이들로부터 전기 에너지를 얻어내고 필요에 따라 터빈 날개가 바람이 부는 방향을 향하도록 yaw-axis 제어를 하는 기술에 관한 것이다.

  • PDF

Study on Performance Variation According to the Arrangements of Adjacent Vertical-Axis Turbines for Tidal Current Energy Conversion (인접한 조류발전용 수직축 터빈의 배치방식에 따른 성능 변화)

  • Lee, Jeong-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.2
    • /
    • pp.151-158
    • /
    • 2016
  • Tidal farm is a multi-arrayed turbine system for utilizing tidal stream energy. For horizontal-axis turbine(HAT) system, it is recommended that each unit has to be deployed far apart in order to avoid hydrodynamic interference among turbines, as proposed by the European Marine Energy Centre(EMEC). But there is no rule for the arrangement of vertical-axis turbine(VAT) yet. Moreover it has been reported that a proper arrangement of adjacent turbines can enhance the overall efficiency even greater than an arrangement without mutual interference effect. This paper suggests the layout of VATs showing the better performances, which turned out to be quite different from HATs' arrangement. Numerical calculations were performed to investigate the performance variation in terms of the rotational direction as well as the distance between turbines. It has been shown that the best combination of rotational direction and distance between turbines can increase its performance higher about 9.2% than that of two independently operated turbines. It is likely that such improvement is due to the increased velocity between adjacent turbines. For diagonally arranged turbines, the maximum normalized mean power coefficient was obtained to be higher about 5.6% than that of two independent turbines. It is expected that the present results can be utilized for conceptual design of tidal farm to harness the tidal stream energy.

Design and CFD study of 360 W class wind turbine tree in accordance with environmental scenery (주위 경관을 고려한 360 W급 풍력터빈나무 설계 및 유동해석)

  • Ha, Min-Su;Jung, Won-Hyuk;Choi, Nak-Joon;Park, Young-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.78-84
    • /
    • 2013
  • The objective of this paper is to develop 360 W class wind turbine tree using a helical type wind turbine. The performance of 100 W class helical wind turbine which finished the conceptual design has been forecast through the CFD analysis. After performed the analysis of one wind turbine performance, four wind turbine have been installed at the structure of a tree type and then the change of a output data has been verified through the CFD analysis. In this study, the CFD results of a helical wind turbine tree have been shown by a velocity and pressure distribution. The result could obtain more than rated power 360 W through the CFD analysis.

Aerodynamic Design and Performance Prediction of Wind Turbine Blade (풍력터빈 블레이드 공력설계 및 성능예측)

  • Kim, Cheol-Wan;Cho, Tae-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.677-681
    • /
    • 2011
  • Characteristics of vertical and horizontal axis wind turbines are explained. The speed and direction of wind on the blade of the Darrieus type turbine changes very severely. Therefore dynamic stall happens periodically and the wake from the front blade deteriorates the performance of rear blades. Blade element momentum theory(BEMT) is widely utilized for aerodynamic design and performace prediction of horizontal axis wind turbine(HAWT). Computation analysis and wind tunnel test are also performed for the performance prediction.

  • PDF

Study on Performance of Vertical-axis Tidal Turbines Applied to the Discharged Channel of Power Plant (조류발전용 수직축 터빈의 방수로 설치에 따른 성능에 관한 연구)

  • Lee, Jeong-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • Thermal and nuclear power plants on shore commonly use the sea water for cooling facility. Discharged cooling water has the high kinematic energy potential due to amount of water flux. Numerical analysis was made to find the suitable combinations between the arrangement of tidal turbines and the overall dimensions of the discharged channel. Several parameters such as the turbine diameter to inlet size, and the axial distance to turbine size were investigated. Power coefficients for various test conditions were also compared to see the effect of inlet configurations such as single inlet and dual inlet. For the single inlet, the mean power coefficient appeared to be gradually decreased with increasing distance, and the maximum power was obtained when the turbine diameter was same as the inlet diameter. For the dual inlet, the tendency was similar so that the better result when the turbine diameter was same as the inlet diameter. It is expected that the present methodology can be extensively utilized to harness the high kinetic energy flow of the discharge channel of power plant.

Development of Hydrodynamic Capacity Evaluation Method for a Vertical-Axis Tidal Stream Turbine (수직축 조류발전 터빈의 유체공학적 용량 산정기법 개발)

  • Lee, D.H;Hyun, B.S.;Lee, J.K.;Kim, M.C.;Rhee, S.H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.2
    • /
    • pp.142-149
    • /
    • 2012
  • This study deals with the investigation of the scale effect for the vertical-axis tidal stream turbine by evaluating the hydrodynamic efficiency of turbine rotors of different diameters at different flow conditions. Numerical analyses are made for the turbine rotors with a same shape, but different sizes obtained using the diameter evaluation equation suggested in this paper. It is shown that the performance of turbine is clearly dependent upon the rotor size and inflow velocity, i.e. Reynolds number dependency of different-scaled turbines showing better efficiency with increasing Reynolds number. The sudden decrease of efficiency is also noticed around the transition region of Reynolds number. The hydrodynamic capacity evaluation method needed at initial stage of turbine design is suggested and exercised with some test cases. It is recommended that the method is expected to be useful for turbines with demanding powers between 10 kW and 300 kW.

Hydrodynamic Aspects on Three-dimensional Effects of Vertical-axis Tidal Stream Turbine (조류발전용 수직축 터빈의 유체동력학적 3차원 효과에 관한 연구)

  • Hyun, B.S.;Lee, J.K.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.61-70
    • /
    • 2013
  • Hydrodynamic aspects on three-dimensional effects were investigated in this study for simple and convenient conversion of tidal stream energy using a Vertical-Axis Turbine (VAT). Numerical approach was made to reveal the differences of flow physics between 2-D estimation and rigorous 3-D simulation. It was shown that the 3-D effects were dominant mainly due to the variation of tip vortices around the tip region of rotor blade, causing the loss of lift for steadily translating hydrofoil and the reduction of torque for rotating turbine blade. The 3-D effect was found to be rather prominent for the typical VATs considered in this paper. Simple and yet efficient 2-D approach with the correction of its three-dimensionality was also proposed for practical design and analysis of VAT.

동해안지역에 적합한 풍력발전시스템에 관한 조사

  • 오철수;강창수;권순홍
    • 전기의세계
    • /
    • v.41 no.10
    • /
    • pp.3-9
    • /
    • 1992
  • 동해안의 6개 예정입지 지점의 다년간 기상데이터를 분석한 결과 3개지점 정도의 유수한 후보지를 발견하였다. 특히 장기갑의 평균풍속은 제주도 월항지역 보다 더 우수한 결과를 얻었다. 이 지역에 설치할 수 있는 풍력터빈의 형식으로 수직축 Darrieus Type을 검토한 결과 무리가 없음을 알 수 있었다. 수직축 터빈은 풍속 6m/s이상이면 정격의 발전모드에 진입하니, 3개 지역의 분석결과 년4000시간 이상의 발전은 가능하리라 사료된다. 단위 풍력발전 용량은 향후 상세설계가 뒤따라야 하겠지만, 대략 150-200KW로 산정되며 년간 단위 기계에서 600-800Mwh의 전력을 얻을 수 있으리라 예상된다.

  • PDF

A Numerical Study of Unsteady Flow around a Vertical Axis Turbine for Tidal Current Energy Conversion (조류발전용 수직축 터빈 주위의 비정상 유동 수치해석)

  • Jung, Hyun-Ju;Rhee, Shin-Hyung;Song, Mu-Seok;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • A numerical investigation was performed based on the Reynolds-Averaged Navier-Stokes(RANS) equations for the two-dimensional unsteady flow around a vertical axis turbine(VAT) with three or four blades. VAT is one of the promising devices for tidal current energy conversion. The geometry of the turbine blade was $NACA65_3$-018 airfoil, for which CFD analysis using Fluent was carried out at several angles of attack and the results were compared with the corresponding experimental data for validation and calibration. Then CFD simulations were carried out for the whole vertical axis turbine with a two-dimensional setup. The CFD simulation demonstrated the usefulness of the method to study the typical unsteady flows around VATs and the results showed that the optimum turbine efficiency could be achieved for carefully selected combinations of the number of blade and Tip-Speed Ratio(TSR).

  • PDF

Shape design and flow analysis on a 200W-class gyromill type vertical axis wind turbine rotor blade (200 W급 자이로밀형 수직축 풍력터빈 로터 블레이드 형상설계 및 유동해석)

  • Cho, Woo-Seok;Kim, Hyun-Su;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.170-177
    • /
    • 2013
  • This study is focused on the shape design and flow analysis on a 200 W-class Gyromill type vertical axis wind turbine rotor blade. Single tube theory is adopted for the shape design of the turbine blade. 2-dimensional CFD analysis is conducted to examine the turbine performance with basic shape, and then 3-dimensional shape is determined from the examination of the performance. By the CFD analysis on the 3-dimensional shape of the wind turbine, performance of the turbine is examined and also, shape of the wind turbine rotor blade is determined accordingly. From the results of this study, a 200 W-class Gyromill type vertical axis wind turbine rotor blade is designed and the reliability of the design method is confirmed by CFD analysis.