• Title/Summary/Keyword: 수직입사

Search Result 218, Processing Time 0.027 seconds

An Experimental Study on the Noise Characteristics and Reduction of a Ventilating Fan System (환기팬 시스템의 소음특성과 저감에 관한 실험적 연구)

  • Kim, Deok-Han;Lee, Dong-Hoon;Kwon, Hyuk-Jung;Kim, Dong-Yun;Lee, Jong-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.500-505
    • /
    • 2005
  • This paper introduces an experimental study for the noise characteristics and reduction of a ventilating fan system. For the purpose of noise reduction of it, an absorptive duct silencer filled with a glass fiber has been conventionally utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with their sound absorption performances.

  • PDF

Design of the Broad-band EM Absorber Using the Improved Partial Initialization Genetic Algorithm (개선된 부분 초기화 유전자 앨거리즘을 이용한 광대역 전파흡수체 설계)

  • 이동근;남기진이상설
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.161-164
    • /
    • 1998
  • 광대역 주파수 상에서 외부로부터 입사하는 전자파를 산란시키지 않고 유전체 내부에서 흡수시키기 위해 유전체를 다층으로 배열하여 전파 흡수체를 최적 설계하고자 한다. 수직 및 여러 각도로 전파가 입사하는 경우 각 유전층의 두께, 유전 상수, 손실 탄젠트 등의 설계변수를 유전자 앨거리즘을 이용하여 최적화한다. 다극함수에서의 부분 초기화 유전자 앨거리즘의 성능 향상을 위해 부분 초기화율, 부분 초기화 시점, 스케일 인자의 변화에 따른 성능을 비교, 개선하여 흡수체 설계에 적용하였다.

  • PDF

Analysis of Scattering of Electromagnetic Wave in Dielectric Periodic Media (유전체 격자구조에서 전자기파의 산란 해석)

  • Kim Min-Nyun;Chae Gyoo-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.247-249
    • /
    • 2004
  • 본 논문에서는 격자구조의 유전체에 수직으로 입사된 전자기파의 산란, 투과 특성을 얇은 위상 막 근사화 이론을 이용하여 분석하였다. 위상 막 근사화 이론은 격자구조가 입사되는 전자기파의 위상 변화만을 주는 것으로 간주하는 것으로 이를 이용하여 격자구조를 통과한 직후인 근거리 필드 분포를 TE 모드에서 계산하였다. 기존의 제시된 이론에 비해 비교적 간단하고 빠르게 산란 필드를 분석할 수 있다.

  • PDF

빗각 증착 기술과 이를 이용한 박막의 제조 및 특성

  • Jeong, Jae-In;Yang, Ji-Hun;Park, Hye-Seon;Jeong, Jae-Hun;Song, Min-A
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.125-125
    • /
    • 2012
  • 물리증착(physical vapor deposition; PVD)은 진공 또는 특정 가스 분위기에서 고상의 물질을 기화시켜 기판에 피막을 형성하는 방법으로 증발과 스퍼터링 그리고 이온플레이팅 등이 있다. PVD 방법으로 박막을 제작하면 대부분의 박막은 주상정 구조로 성장하게 된다. 이러한 주상정의 조직을 제어하는 방법으로 빗각 증착(oblique angle deposition; OAD) 기술이 있다. OAD는 타겟(증발원)에 대해서 기판을 평행하게 배치하는 일반적인 코팅방법과는 달리 기판의 수직성분과 타겟의 수직성분이 이루는 각도가 0도 이상이 되도록 조절하여 기판을 기울인 상태로 코팅하는 방법을 말한다. OAD 방법을 이용하면 기판으로 입사하는 증기가 초기에 생성된 핵(seed)에 의해 shadowing이 발생하면서 증기가 수직으로 입사하는 normal 증착과는 다른 형상의 성장 조직이 만들어지게 된다. 본 논문에서는 OAD 방법을 이용하여 Al과 TiN 박막을 제조하고 그 특성을 비교하였다. Al 박막은 UBM (Un-Balanced Magnetron) 스퍼터링 소스를 이용하여 빗각을 각각 0, 30, 45, 60 및 90도의 각도에서 강판 및 실리콘 웨이퍼 상에 시편을 제조하되 단층 및 다층으로 시편을 제조하고 치밀도와 함께 조도와 반사율을 비교하고 염수분무시험을 이용하여 내식성을 평가하였다. TiN 박막은 Cathodic Arc 방식을 이용하되 Al 박막과 동일한 방법으로 코팅을 하고 내식성 및 경도 등의 특성을 비교하였다. TiN 박막은 경사각이 커지면서 경도가 낮아졌으나 바이어스 전압을 이용하여 다층으로 제조함에 의해 경도는 유지하면서 modulus를 낮출 수 있어서 박막의 신뢰성을 나타내는 H3/E2 값은 증가함을 알 수 있었다.

  • PDF

빗각 증착을 이용한 알루미늄 박막의 구조 제어

  • Yang, Ji-Hun;Park, Hye-Seon;Jeong, Jae-Hun;Song, Min-A;Jeong, Jae-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.182-182
    • /
    • 2013
  • 빗각 증착은 입사 증기가 기판에 수직하게 입사하는 일반적인 공정과는 다르게 증기가 기판의 수직선과 $0^{\circ}$ 이상의 각을 갖는 증착 방법을 의미한다. 빗각 증착으로 코팅층의 구조를 제어하기 위해서는 기판에 입사되는 코팅 물질의 증기가 일정한 각도를 유지해야한다. 공정 압력이 높아서 증기의 자유행로가 짧아지면 기판에 도달하는 코팅 물질이 일정한 각도를 유지하지 못하기 때문에 코팅층의 구조제어가 어렵고 일반적인 코팅 공정과 유사한 구조의 코팅층을 얻게 된다. 빗각 증착을 공정 압력이 비교적 낮은 전자빔 증착이나 열 기상증착 등의 코팅 공정에서 실시하는 이유이다. 본 연구는 공정 압력이 ${\sim}10^{-3}$ torr로 비교적 높은 스퍼터링 공정에서 빗각 증착을 실시하여 코팅층의 구조제어가 가능한지를 확인하였다. 실험에 사용된 물질은 알루미늄이었으며 빗각은 $0{\sim}90^{\circ}$를 사용하였다. 실험 결과 빗각의 크기가 $60^{\circ}$ 이하에서는 알루미늄 박막의 구조 변화를 관찰하지 못했으며 $45^{\circ}$와 같은 특정한 빗각에서 밀도가 높은 코팅층을 확인할 수 있었다. 이러한 높은 밀도를 갖는 알루미늄 박막은 강판의 부식을 방지하기 위한 보호막으로 적용이 가능할 것으로 판단되며 염수분무시험 결과 200시간 이상의 높은 적청 발생 시간을 보였다. $60^{\circ}$ 이상의 빗각으로 코팅된 알루미늄 박막에서 독립적으로 형성된 주상정을 관찰할 수 있었다. 빗각의 크기가 $90^{\circ}$로 스퍼터링 타겟과 기판을 수직하게 위치시켜도 알루미늄 박막이 코팅되는 것을 확인할 수 있었으며 일정한 각도를 가지는 주상정을 관찰할 수 있었다. 이러한 주상정의 알루미늄은 비교적 큰 표면적을 가지고 있기 때문에 가스 센서 등 다양한 응용분야에 적용이 가능할 것으로 판단된다. 앞서 설명한 실험결과와 같이 스퍼터링과 같이 공정 압력이 비교적 높은 공정에서도 빗각 증착을 이용한 코팅층의 구조 제어가 가능하다는 것을 확인할 수 있었다.

  • PDF

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.

SH Wave Scattering from Cracks: Comparisons of Approximate and Exact Solutions (SH파의 균열 산란장 해석: 근사해와 엄밀해의 비교)

  • Jeong, Hyun-Jo;Park, Moon-Cheol;Song, Sung-Jin;Schmerr, L.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.354-361
    • /
    • 2004
  • This Paper describes a crack scattering model for SH wave based on the boundary integral equation(BIE) method, where the fundamental unknown is crack opening displacement(COD). When a time harmonic plane wave was incident on a 2-D isolated crack (slit) of width 2a, the COD distributions were numerically calculated as a function of ka. The calculated COD agreed well with results obtained with other methods. The far-field scattering amplitude, which completely characterizes the flaw response, was calculated in two ways. The Kirchhoff approximation and the BIE-COD exact formulation were compared in terms of incidence angle and frequency ka in a pulse-echo mode. Maximum response was obtained for both methods at the specular reflection direction. Away from the specular direction, the Kirchhoff approximation becomes less accurate. The time domain crack response was also calculated using a band-limited spectrum of center frequency 10 MHz. At oblique incidence to the crack both methods show the existence of an antisymmetric flash points occurring from the crack edge. The Kirchhoff approximation provides an exact time interval between flash points, although it unrealistically gives the same amplitude.

The Study on the Improvement of Antireflection Coating Efficiency According to the Angle of Incidence (입사각에 따른 반사방지막 성능 개선에 관한 연구)

  • Kim, Chang-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4131-4136
    • /
    • 2015
  • This paper compares and calculates more precisely the averaged reflectance of antireflection coating with different structure of single and 6 layer assuming the incident angle of light changing from $8^{\circ}$ to $60^{\circ}$ not like normal incidence as usual case. The reflectivity of AR coating of 6 layers with 180 nm thickness having index profile suggested as linear and quintic function and single layer with same thickness having even index are calculated and compared, when the wavelength of incident light ranges from 400 nm to 1200 nm. As the results the AR coating with 6 layers having quintic(linear) function index profile shows the lower reflectance about 11.6 %(14.6 %) than other index profiles, which is approximately 8 % lower reflectance compared with single layer case(about 19.6 %). This results could be applied for the better antireflection coating design applying to optical devices and filters.