• Title/Summary/Keyword: 수용시설물

Search Result 62, Processing Time 0.04 seconds

Decision technique for accommodation facilities of multi-utility tunnel in basic planning phase (기본 계획 단계에서의 공동구 수용시설물 결정 기법)

  • Oh, Won-Joon;Jin, Kyu-Nam;Kang, Yeong-Ku;Cho, Choong-Yeun;Sim, Young-Jong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.79-92
    • /
    • 2019
  • In this paper, we propose a method to determine whether to install the accommodation facility of the multi-utility tunnel more effectively in the basic planning phase, and to set up an evaluation system to determine the configuration and kind of accommodation facility. For the configuration of the accommodation facility, 98 alternatives were analyzed for 7 accommodation facility. For the evaluation system of the accommodation facility, index related to feasibility and economic in basic planning phase were selected. The evaluation system classified as spatial, effective, and cost evaluation was presented reflecting the selected index, and AHP analysis was performed for weight setting. The results of this study will be helpful for users including designers to shorten the time and increase the efficiency in the process of determining accommodation facility of the multi-utility tunnel in basic planning phase.

Optimal alternative decision technique of accommodation facility in multi-utility tunnel using VE/LCC analysis (VE/LCC 분석을 통한 공동구 수용시설물의 최적 대안 결정 기법)

  • Sim, oung-Jong;Jin, Kyu-Nam;Oh, Won-Joon;Cho, Choong-Yeun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.317-329
    • /
    • 2018
  • The study on the existing multi-utility tunnel has examined the general aspects related to the installation of multi-utility tunnel rather than the optimal design and feasibility analysis of accommodation facility in multi-utility tunnel. In the basic planning stage related to the introduction of multi-utility tunnel, it is difficult to determine accommodation facility due to lack of relevant indicators and data. In this paper, VE/LCC analysis method is suggested for the optimal alternative decision of accommodation facilities in multi-utility tunnel. The analysis of the items of individual accommodation facility and the value index for LCC costs were applied to the kind alternatives, and the priorities of each kind were analyzed. In addition, the domestic multi-utility tunnel and analysis result are compared. The result of this study will be helpful to shorten the time and convenience of the user in the process of determining accommodation facility including the first designers when introducing multi-utility tunnel.

Development of Underground Conduits Eco-Monitoring System (지하공간 환경 모니터링 시스템 개발 및 시험)

  • Park, Jungl-Kwon;Han, Jin-Woo;Kang, Wang-Kyu;Woo, Byong-Soo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.40-44
    • /
    • 2009
  • 지하구는 도시의 신경망이라 할 수 있는 통신, 전력, 상수도, 난방, 쓰레기 처리시설 등 도시 운용/관리를 위한 주요시설물을 안전하게 수용하고, 유지 관리하기 위한 시설로 IT기술을 이용하여 수용된 시설을 효과적으로 유지/관리하고, 재난으로부터 안전하게 보호함과 동시에 최소의 비용과 에너지로 수용된 시설물을 유지관리하기 위한 연구가 많이 진행되고 있다. 따라서 본 논문에서는 지하구(공동구, 통신구, 전력구)의 운용 및 유지관리와 지하구에서 발생될 수 있는 각종 재난에 대응하기 위한 지하구 운용 및 유지관리에 대해 알아보고, 지하구 내부에 수용된 시설물을 효과적으로 유지관리하고 재난에 신속히 대응하기 위한 지하구 환경모니터링 시스템에 대해 기술 하고자 한다. 지하구 환경모니터링 시스템은 지하구 내부에는 전력, 상수도, 통신, 난방 등 다양한 시설물이 수용되어 있으며, 이러한 시설물의 부식, 고장 등으로부터 보호하기 위해 지하구내부의 환기시스템의 송풍기와 지하수와 기상재해로 인한 지하구 및 수용시설물의 침수를 막기 위한 양수펌프에 대해 실시간 상태모니터링 통해 송풍기 및 펌프의 고장여부를 판단하여 관리자에게 알림으로써 관리자가 신속하게 대응 할 수 있도록 하였다. 송풍기의 제어는 지하의 내부와 외부에 설치된 온/습도 센서를 통해 지하구 내부환경을 최적으로 유지할 수 있도록 함으로써 쾌적한 지하 내부환경 유지하고, 급/배기가 필요할 경우에만 송풍기를 가동함으로써 에너지를 절약 할 수 있으며, 화재, 침수 등에 대한 재난시 환풍기의 급/배기, 정지 등을 신속하게 제어할 수 있도록 하였다. 또한 지하구내부에서 발생된 재난을 유/무선을 이용하여 신속하게 지하구 주변의 장치(U-Pole 또는 통합컨트롤러)를 통해 경보를 전파함으로써 주변 시민들이 안전하게 대피할 수 있도록 하였다. 그리고 지하구 환경모니터링 시스템을 검증하기 위해 실제 지하구 및 실험실에 시스템 및 Test Board을 설치하여 운용시험을 실시 하였다.

  • PDF

A Study on the Design Status of Public Facilities in Busan Songdo Beach (부산 송도해수욕장 공공시설물의 디자인 현황 연구)

  • Wang, dan;Yoon, Ji-Young
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2019.05a
    • /
    • pp.397-398
    • /
    • 2019
  • 본 논문은 부산의 대표적 송도해수욕장를 주요 연구대상으로 하여, 해수욕장내의 편의시설물과 유니버설디자인 간의 관계를 파악 하고자 한다. 사례에서 관련된 편의시설물의 유형에 대한 분석을 통해 편의시설물의 추후 발전 추이를 발견하고 미래의 디자인 방향에 참고를 제공 한다. 문헌고찰로 편의시설물 개념, 유니버설디자인 개념 및 평가요소 등을 전반적으로 이해하고 연구하여, 현장조사로 송도해수욕장내의 편의시설물 현황 파악한다. 현재 송도해수욕장의 유니버설디자인이 적용된 편의시설물의 특성 중에서는 사용성, 접근성요소가 가장 많이 적용된 것으로 나타났다. 그러나 수용성, 안전성요소가 부족함에 따라 다양한 옵션이 제공된 시설물에 대한 개발 및 연구가 필요하다.

  • PDF

Real-time Underground Facility Map Production Using Drones (드론을 이용한 실시간 지하시설물도 작성)

  • NO, Hong-Suk;BAEK, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.4
    • /
    • pp.39-54
    • /
    • 2017
  • Between 1998 and 2010, the computerization of underground facilities was completed in 84 cities. Since 2011, new pipelines have been laid or existing pipelines have been maintained, renovated, and renewed. To measure the exact location and depth of the exposure pipe, a map of underground facilities was created before filling the ground. This method is based on the time when the underground facilities of the National Geographic Information Institute Regulation No. 134 of the National Geographic Information Office revised in 2010 were drafted. The process of the drone taking the video is based on a theoretical basis of ground control points. The method works by removing all ground control points located outside of the error range and re-processing it for calculating the best result. Furthermore, using a drone-based spontaneous measuring method allows workers to obtain a high accuracy underground facilities map in error bound. The proposed method could be used as a new way to standardize the processing.

Development of modernizing Old Small-Hydropower system with custom-built at Overseas (해외 노후 수력발전시스템 수용가 맞춤형 현대화 기술개발 및 실증)

  • Kim, Woonhak;Kang, Seokwon;Shin, Giseok
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.174-181
    • /
    • 2018
  • Purpose: The purpose of this study is to develop and demonstrate the customized modernization technology of the old aged hydropower generation system in operation Method: The modernization design was carried out based on the daily, weekly, monthly, and yearly information of the power plant in operation at the site. Results: In this paper, a safety diagnosis of existing facilities located in the Philippiness was carried out in accordance with the Special Act on the Safety Management of Domestic Facilities, and a method for reinforcing the facilities was selected. Conclusion: The selection of wheel suitable for the local environment and the maintenance of the old facilities were designed by domestic repair/reinforcement technology.

Analysis of Disaster for Common Utility Tunnel & Schemes of Establishing Construction criteria (공동구 재해사례와 건설기준 제정방안)

  • Yoo, Jai-Sung;Lim, Jong-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1236-1245
    • /
    • 2009
  • 공동구는 도시생활을 영위하는 데 필요한 전기, 가스, 상 하수도, 전화, 통신 등의 공공시설물을 지하매설물 형태로 설치하여 시민들의 일상생활 및 사회 경제활동의 편의성을 제공하고 안전하고 안락한 도시환경을 유지시키며, 효율적인 도시운영이 가능케 하는 공공시설물이다. 그러나, 최근 들어 여의도 공동구 화재(2000년), 여수 공동구 침수(2003년), 구리시 전력구 화재(2006)등과 같이 공동구 및 전력구에서의 화재, 혹은 침수 등에 의해 재해가 발생하여 이로 인한 국가적 경제적, 사회적 손실이 늘어가고 있다. 하지만 국내에서는 공동구내 설비를 화재 및 재해로부터 보호하기 위한 법적 장치가 미비한 실정이며, 현재 운영되고 있는 공동구의 관리 또한 시설관리공단이나 위탁관리기관 등으로 분산되어 있어 일정한 시설물 설치기준이나 유지관리제도가 정립되지 못하여 효율적인 운영이 이루어지지 않다고 판단된다. 본 연구에서는 근래 국내에서 발생한 공동구 재해사례와 공동구 관련 법규를 검토 분석하였으며, 다양화되어 가는 공동구 수용시설 조건에 부합하고 체계적이고 효율적인 공동구의 시공을 위한 공동구 건설기준 제정방안을 도출하였다.

  • PDF

Site Selection for Public Facility Using Geo-spatial Information Analysis Technique (공간정보분석기법을 이용한 공공시설물의 적지분석)

  • Han, seung-hee
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.449-450
    • /
    • 2017
  • 공공시설물 건설을 위한 적지분석을 위해서는 대상지에 국유지 또는 시유지(지자체소유)의 포함비율이 중요한 요소가 된다. 일반 건설과는 다르게 사업예산을 축소하기 위해서 국가 또는 지자체소유의 토지를 포함할 수 있다는 특수성이 있기 때문이다. 사유지를 수용할 경우 소유자와 필지수 그리고 지가 등이 판단요소가 된다. 뿐만 아니라 물리적조건으로 경사도, 향(aspect), 교통편이성 등이 동시에 분석되어야 한다. 본 연구에서는 속성과 공간적인 분석을 통해 공공시설물의 적지분석을 수행하였다.

  • PDF

A Case of Smart Space Service Based on Intelligent Street Light U-Pole (지능형 가로등 U-Pole기반 공간지능화 서비스 사례)

  • Kim, Jung-Guen;Baik, Song-Hoon
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.123-128
    • /
    • 2008
  • 생활공간의 혁신적인 발전은 U-City라는 형태로 추진되고 가시화되고 있으며 특히 U-City의 옥외 공간에서 이뤄지는 서비스는 공간이 지능화되고 다양한 형태의 단말을 통해 보다 능동적이고 찾아가는 형태로 제시되고 있다. 그러나 이러한 서비스를 실현하기 위해서는 옥외공간에 다양한 서비스 장비가 설치, 운용되어야 하는데 KT는 이를 효과적으로 구성하고 구현할 수 있는 IT인프라로서 도시 야간 필수 시설물이며 도시미관을 해치지 않는 가로등 형태로 수용하여 서비스 구현에 필요한 장비를 수용하는 지능형 가로등 U-Pole을 개발해오고 있다. 본 논문에서는 U-Pole로 구성된 현장 서비스 제공 플랫폼과 옥외 공간지능화 서비스 사례를 소개하고자 한다.

  • PDF