• Title/Summary/Keyword: 수술 계획

Search Result 506, Processing Time 0.024 seconds

Factors Depending on the Possibility to Prevent Elective Operation Cancellation using Medical Record (보건정보를 활용한 수술취소 예방가능 여부 요인에 관한연구)

  • Lee, Mi-Jung;Lee, Moo-Sik;Ahn, Sang-Yoon;Kim, Yong-Ha;Kim, Kwang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.361-367
    • /
    • 2010
  • The study was conducted on a total of 146 patients who cancelled planned surgeries at a University Hospital located in Daejeon for one year from Jan., 1 to Dec., 31, 2007 with the purpose of minimizing cancellation ratio of planned surgeries and thereby improving hospital management reasonably and raising service satisfaction. Participants in this study consisted of 56.8% of male patients and 43.2% of female patients, with a higher proportion of female than male patients. The causes of cancelled planned surgeries were classified into controllable and uncontrollable cases. 60.0% of the cases that cancelled planned surgeries were classified into controllable cases based on the classification of surgical risk. From these findings, the study proposes that researchers and hospital managers establish policy directions to reduce and improve surgery cancellation ratio.

Radiation Dose Accuracy 81 the Isocenter : Standard Stereotactic Radiosurgery Technique Developed at Seoul National University Hospital (서울대학교병원형 방사선수술 표준기법의 중심점 선량의 오차)

  • Shin Seong Soo;Kim Il Han;Ha Sung Whan;Park Charn Il;Kang Wee-Saing;Hur Sun Nyung
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.391-395
    • /
    • 2002
  • Purpose : To confirm the accuracy of the radiation dose at the isocenter by the standard linear accelerator-based stereotactic radiosurgery technique which was developed at Seoul National University Hospital. Materials and Methods : Radiation dosimetry was undertaken during standard 5-arc radiosurgery using 6 MV X-ray beam from CL2100C linac. The treatment head was attached with circular tertiary collimators of 10 and 20 mm diameter. We measured the absorbed dose at the isocenter of a multi-purpose phantom using two kinds of detector : a 0.125 co ionization chamber and a silicon diode detector. Results : The dose differences at each arc plane between the planned dose and the measured dose at the isocenter raged from $-0.73\%\;to\;-2.69\%$ with the 0.125 cc ion chamber, and from $-1.29\%\;to\;-2.91\%$ with the diode detector during radiosurgery with the tertiary collimator of 20 mm diameter. Those with the 10-mm tertiary collimator ranged from $-2.39\%\;to\;-4.25\%$ with the diode. Conclusion : The dose accuracy at the isocenter was ${\pm}3\%$. Therefore, further efforts such ws modification in processing of the archived image through DICOM3.0 format are required to lessen the dose difference.

성인병 뉴스 제303호

  • The Korea Association of Chronic Disease
    • The Korean Chronic Disease News
    • /
    • no.303
    • /
    • pp.1-18
    • /
    • 2006
  • 한국만성질환관리협회 신준식 부회장/국가 심.뇌혈관 질환 예방위 설치/약제비 절감‘포지티브’제도 강행/6월부터 환자 식대 보험 적용 확정/말기암 환자 호스피스기관 선정/“농촌지역 암.만성질환 관리 시급”/의료법인, 세제개선 헌법소원 추진/‘신약인프라 구축’5개년 계획 추진/화장품에 인태반 원료 사용 금지/약국 간판.광고 규제 대폭 완화/‘한방의학으로 수술 않고, 척추질환 치료’/“건강의 비결은 걷는데 있다”/식이섬유 1일 평균 19.8g 섭취/식도암, 내시경 수술 효과 좋았다/만성질환 관리의 현황과 발전방향/“40~50대 파킨슨병 발생 많다”/전립선비대증 치료‘시알리스’효과 있다/위암 수술 후‘젤로다+ 엘록사틴’투여 평가/

  • PDF

Two treatment approach to skeletal class III : A case report on sisters (골격성 III급 부정교합 환자 자매의 치험례)

  • Lee, Yu-Hyun
    • The korean journal of orthodontics
    • /
    • v.29 no.3 s.74
    • /
    • pp.327-337
    • /
    • 1999
  • Patients with skeletal class III can be succesfully treated by either orthognathic surgery or orthodontic treatment owing to unavoidable circumstances. Systers were treated , elder syster by orthognathic surgery and younger one by compromised treatment. For the ideal treatment goal, orthognathic surgery will be inevitable in skeletal problem case, but by the patient's private situations orthodontist cannot help doing compromised treatment. It could be another option if correct biomechanical approach is used.

  • PDF

Three-Dimensional Dose Distribution for the System of Linear Accelerator-based Stereotactic Radiosurgery (LINAC을 이용한 뇌정위적 방사선 수술에 대한 3 차원 선량분포)

  • Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.121-128
    • /
    • 1991
  • Radiosurgery treatment in the brain requires detailed information on three-dimensional dose distribution. A three-dimensional treatment planning is a prerequisite for treatment plan optimization. It must cover 3-D methods for representing the patient, the dose distributions, and beam settings. Three-dimensional dose models for non-coplanar moving arcs were developed using measured single beam data and efficient 3-D dose algorithms for circular fields. The implementation of three dimensional dose algorithms with stereotactic radiosurgery and the application of the algorithms to several cases are discussed.

  • PDF

Rapid Prototyping in Medical Application (쾌속 조형 기술의 의료 분야 적용)

  • Lee, Jong-Ki;Kim, Jong-Se;Kim, Cheol-Young;Kim, Nam-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.172-175
    • /
    • 2001
  • 쾌속조형기술은 제품 설계나 기타 물체의 형상 데이터로부터 광경화성 수지, 금속 등 다양한 재료를 이용하여 수 시간 내에 실물 모형을 제작할 수 있는 기술이다. 쾌속조형기술은 주로 자동차나 제품의 모형제작에 주로 사용되어 왔다. 사이버메드에서는 인체에 대한 3차원 형상화 기술과 쾌속조형기술을 이용하여 개인별로 상이한 인체 골격에 대한 비교적 저렴한 비용으로 실물 모형을 제작할 수 있는 기술을 개발하여, 국내 및 일본의 병원에서 수술 계획 및 모형 수술에 직접 적용하고 있다. 이 논문은 쾌속 조형 기술, 인체의 3차원 형상화 기술의 개요와 그 동향, 그리고 이를 결합한 수술용 인체 골격모형의 제작 기술과 적용 사례에 대해서 기술하였다.

  • PDF

An assessment of accuracy of half-guided implant surgery using implant surgical guide: A case report (임플란트 수술용 가이드를 사용한 부분 유도 임플란트 수술의 정확도 평가: 증례보고)

  • Kim, Choongkil;Lee, Wonsup;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.150-159
    • /
    • 2019
  • Nowadays, dental implant is one of the widely used treatment options for edentulous patients. Recently, a method of improving the accuracy of implant surgery using an implant surgical guide has been introduced and widely used in order to accurately place the implant in a proper position. Full-guided and half-guided implant surgery can be distinguished according to the level of surgical guide application during the implant surgery. It is true that full-guided implant surgery exhibits higher accuracy, but half- guided implant surgery is often performed in a clinical situation due to the factors such as the circumstances of the operation. A partially edentulous patient who lost teeth due to tooth fracture and periodontal disease was treated using implant and fixed prosthesis. Half-guided implant surgery was performed using an implant surgical guide during implant surgery, the accuracy of implant placement was analyzed.

Design and Implementation of A Medical Image Guided System for Vertebroplasty (척추성형술을 위한 의료 영상 시스템의 설계 및 개발)

  • Tack, Gye-Rae;Lee, Sang-Bum;Lee, Sung-Jae
    • The KIPS Transactions:PartB
    • /
    • v.10B no.5
    • /
    • pp.503-508
    • /
    • 2003
  • Since surgical treatment of the spine should overcome neurological compromises, the operative procedures need to be carefully planned and carried out with high degree of precision. Percutaneous vertebroplasty is a surgical procedure that was introduced for the treatment of compression fracture of the vertebrae. This procedure includes puncturing vertebrae and filling with polymethylmethacrylate (PMMA). Recent studies have shown that the procedure could provide structural reinforcement for the osteoporotic vertebrae while being minimally invasive and safe with immediate relief of pain. However, failures of treatment due to excessive PMMA volume injection have been reported as one of complications in vertebroplasty. It is believed that the control of PMMA volume is one of the most critical factors that can reduce the incidence of complications. Therefore, clinical success of vertebroplasty can be dependent on the volume of PMMA injection for a given patient. In this study, the optimal volume of PMMA injection for vertebroplasty was predicted based on the image analysis of a given patient.

Surgical Planning in Deformity Correction Osteotomies using Forward Kinematics and Inverse Kinematics (정기구학 및 역기구학을이용한하지 교정절골술 계획 생성)

  • Jeong, Jiwon;Lee, Seung Yeol;Youn, Kibeom;Park, Moon Seok;Lee, Jehee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • Patients with cerebral palsy or arthritis have deformities in lower limb which cause unstable gait or posture and pains. Surgeons perform a deformity correction osteotomy with surgical plan. But sometimes they find the unexpected angular or rotational deformation after surgery. The problems are that there is no method to predict the result of a surgical plan and also there are so many factors to must consider in surgical planning step such as clinical measurements, rotation angle, wedge angle, morphology of lower limb, etc. This paper presents new methods for planning the deformity correction osteotomy efficiently. There are two approaches based on the 3D mesh model and the accurate assessment of the patient's lower limb. One is the manual pre-simulation of surgery using forward kinematics. And the other is the automatic surgical planning using inverse kinematics and nonlinear optimization. Using these methods, we can predict and verify the results of various surgical treatments and also we can find a more effective surgical plan easily compared to conventional methods.

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.