• Title/Summary/Keyword: 수소-LPG

Search Result 80, Processing Time 0.025 seconds

Explosion-proof LNG/LPG and solvent sensors (방폭형 LNG/LNG 및 솔벤트 센서)

  • Cha, Sung-Ik;Shin, Paik-Kyun;Lee, Boong-Joo;Joo, Sang-Heun;Kim, Jong-Won;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1475-1477
    • /
    • 2003
  • 본 논문에서는 LNG/LPG 센서와 솔벤트 센서를 국산화한 결과를 보고한다. LNG/LPG 센서는 $SnO_{2-}\;WO_3$ 모물질에 Pd, Pt 촉매를 첨가하여 제작하였다. 센서를 $400^{\circ}C$ 이상에서 동작시키면 CO가 촉매층에서 거의 $CO_2$로 산화되어 감지막의 저항변화에 아무런 기여도 못하기 때문에 팔라듐 촉매 센서부와 백금촉매 센서부의 신호로부터 탄화수소와 CO를 구별할 수 있다. 또한 촉매층 위에 다공성 보호층를 형성하여 촉매층과 감지막을 보호함으로써 장기 안정성이 크게 향상 되었다. 한편, 감지물질로 $BaSnO_3$를 사용해 제작된 솔벤트 센서는 에탄올에 매우 우수한 감도와 선택성을 나타내었다.

  • PDF

Study on the Performance and Emission Characteristics of a DI Diesel Engine Operated with LPG / Bio-diesel Blended Fuel (LPG/바이오디젤 혼합연료를 사용하는 직접분사식 디젤엔진의 성능 및 배기특성에 관한 연구)

  • Lee, Seok-Hwan;Oh, Seung-Mook;Choi, Young;Kang, Kern-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.8-14
    • /
    • 2010
  • In this study, we experimentally investigated a compression ignition engine operated with Bio-diesel blended LPG fuel. In particular, the performance, emissions characteristics (including total hydrocarbon, carbon monoxide, nitrogen oxides, and carbon dioxides emissions), and combustion stability of a CI engine fueled with Bio-diesel blended LPG fuel were examined at 1500 rpm. The percentage of Bio-diesel in the fuel blend ranged from 20-60%. The results showed that stable engine operation was possible for a wide range of engine loads up to 40% Bio-diesel by mass. When the Bio-diesel content was increased, leading to a decrease in the lower heating value of the blended fuel, the cetane value increased, resulting in a advanced start of heat release. Exhaust emission measurements showed that THC and CO emissions were increased when using the blended fuel at low engine speeds due to partial burn from over-mixing. NOx emission was emitted less at lower loads and more at higher loads.

Study of Combustion Characteristics with Compression Ratio Change in Ultra-Lean LPG Direct Injection Engine (압축비 변화에 따른 초희박 직접분사식 LPG엔진의 연소특성 연구)

  • Cho, See Hyeon;Yoon, Jun Kyu;Park, Cheol Woong;Oh, Seung Mook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.837-844
    • /
    • 2014
  • Automotive manufacturers have recently developed various technologies for improving fuel economy and satisfying enhanced emission regulations. The ultra-lean direct injection engine is a promising technology because it has the advantage of improving thermal efficiency through the deliberate control of ignition. A conventional LPG engine has been redesigned to an ultra-lean-burn LPG direct injection engine in order to adopt combustion system of ultra-lean-burn. This study is aimed at investigating the effect of a change in the compression ratio on the performance and emission characteristics of a lean-burn LPG engine. The fuel consumption, heat release rate, combustion pressure, and emission characteristics are estimated depending on changing the effect of compression ratio. When the compression ratio is increased, it is difficult to improve the fuel consumption owing to an unstable combustion state, but the total hydrocarbon and nitrogen oxide emissions are reduced.

An Analysis of Accessibility to Hydrogen Charging Stations in Seoul Based on Location-Allocation Models (입지배분모형 기반의 서울시 수소충전소 접근성 분석)

  • Sang-Gyoon Kim;Jong-Seok Won;Yong-Beom Pyeon;Min-Kyung Cho
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.339-350
    • /
    • 2024
  • Purpose: This study analyzes accessibility of 10 hydrogen charging stations in Seoul and identifies areas that were difficult to access. The purpose is to re-analyze accessibility by adding a new location in terms of equity and safety of location placement, and then draw implications by comparing the improvement effects. Method: By applying the location-allocation model and the service area model based on network analysis of the ArcGIS program, areas with weak access were identified. The location selection method applied the 'Minimize Facilities' method in consideration of the need for rapid arrival to insufficient hydrogen charging stations. The limit distance for arrival within a specific time was analyzed by applying the average vehicle traffic speed(23.1km/h, Seoul Open Data Square) in 2022 to three categories: 3,850m(10minutes), 5,775m(15minutes), 7,700m(20minutes). In order to minimize conflicts over the installation of hydrogen charging stations, special standards of the Ministry of Trade, Industry and Energy applied to derive candidate sites for additional installation of hydrogen charging stations among existing gas stations and LPG/CNG charging stations. Result: As a result of the analysis, it was confirmed that accessibility was significantly improved by installing 5 new hydrogen charging stations at relatively safe gas stations and LPG/CNG charging stations in areas where access to the existing 10 hydrogen charging stations is weak within 20 minutes. Nevertheless, it was found that there are still areas where access remains difficult. Conclusion: The location allocation model is used to identify areas where access to hydrogen charging stations is difficult and prioritize installation, decision-making to select locations for hydrogen charging stations based on scientific evidence can be supported.

Effects of Operation Conditions on Hydrocarbon Components Emitted from SI Engine with Gaseous Fuels (기체 연료를 사용한 전기점화기관에서 운전조건이 HC 배출물 성분에 미치는 영향)

  • 박종범;최희명;이형승;김응서
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.108-121
    • /
    • 1998
  • Using gas chromatography, the light hydrocarbon emissions were analyzed from SI engine fueled with methane and liquified petroleum gas(LPG), and the effects of fuel and engine operating condition were discussed. For this purpose, 14 species of light hydrocarbon including 1, 3-butadiene were separated, calibrated with standard gas, and measured from undiluted emissions. The brake specific hydrocarbon emission(BSHC) and ozone forming potential(BSO)3 were calculated and discussed with the changes of fuel, engine speed, load, fuel/air equivalence ratio, coolant temperature, and spark timing. As a result, exhaust emission was composed of mainly fuel composed of mainly fuel comp- onent and other olefin components of similar carbon number. The olefin components such as ethylene and propylene determine most of the ozone forming potential. The fraction of fuel component in total hydrocarbon emission was bigger with methane fuel than with LPG fuel. Also fuel fraction increased at high speed or high speed or high temperature of exhaust gas, and to lesser extent with high coolant temperature and retarded spark. However, the effect of equivalence ratio had different tendency according to fuels.

  • PDF

An Experimental Study on Individual HC Emission Characteristics and Startability for Various Composition Ratio of LPG Fuel on LPLi Engine (LPLi엔진에서의 LPG 연료 조성비가 개별탄화수소 배출특성과 시동성에 미치는 영향에 대한 연구)

  • Choi, Seong-Won;Kwak, Ho-Chul;Myung, Cha-Lee;Park, Sim-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.3 s.258
    • /
    • pp.234-241
    • /
    • 2007
  • The regulations for hydrocarbon emission from vehicles have become much more stringent in recent years. These more stringent regulations request vehicle manufacturers to develop the advanced exhaust system for reducing exhaust emissions. The exhaust emissions has many sources in vehicle. In order to investigate the characteristics of hydrocarbon(HC) in the exhaust manifold, concentrations of individual HC species were measured in exhaust process. Using sampling valve, the light hydrocarbon emissions were captured in the exhaust manifold(catalyst before and after) and analyzed from LPLi engine exhaust manifold(catalyst before and after) using different fuel properties. Then exhaust samples were measured by gas chromatography(GC) and exhaust gas analyzer. Catalyst conversion efficiency for fuel properties of Butane 100% was better than Propane 100%. Start delay of LPLi engine was observed as increment of propane contents in LPG fuels.

Hydrogen production from dimethyl Ether (디메틸 에테르를 이용한 수소 생산)

  • Lee Sang-Heon;Yim Sung-Dae;Park Gu-Gon;Yu Sang-Phil;Yoon Young-Gi;Kim Chang-Soo;Park Seung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.303-305
    • /
    • 2005
  • 현재 인류가 직면하고 있는 에너지 및 환경 문제를 해결할 수 있는 최선의 대안으로서 수소 에너지 및 연료전지 기술에 대한 연구가 활발히 진행 중이다. 본 연구에서는 디메틸 에테르를 이용한 수소 생산 기술에 대한 연구를 수행하였다 디메틸 에테르(BATE)는 안정한 화합물로서 비 활성적이고 부식성이 없으며 발암성 및 마취성이 얼어 인체에 무해한 청청 연료로서 각광을 받고 있으며 특히 기존의 LPG 인프라를 그대로 사용할 수 있는 장점 등으로 수소 스테이션 및 소형 연료전지용 수소 발생기 등에의 적용을 위한 연구가 활발히 진행 중이다. 본 연구에서는 이러한 응용을 위한 수소 발생기용 DME 개질 반응기의 개발을 위하여 본 반응에 대한 촉매 종류의 영향, 공간속도의 최적화, 반응 메카니즘에 따른 촉매 선정, 반응온도 등의 다양한 반웅 조건에 대한 영향을 확인하고 실제 소형 연료전지를 위한 수소공급 장치로서 적용코자 마이크로채널 반응기에 적용하여 마이크로채널 DME 개질반응기의 컴팩트한 수소공급 장치로서의 적용 가능성을 평가하였다.

  • PDF

Development of Sensor Module and Control System Software for LPG/CNG Stations (LPG/CNG용 센서 모듈 및 관제시스템 S/W 개발)

  • Cho, Beomsek;Kim, Sungkwang;Kim, Sungtae;Kim, Jongmin
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.53-59
    • /
    • 2018
  • In Korea, The number of installed LPG Charging stations is about 2000, increasing by 26 every year. In these, about 500 charging stations are older above 15 year, accounting about 25% of total stations. About 86% of them are located in the city, which is causing serious damage if accident occurs. In this paper, we developed a duel gas sensor module and integrated control system software that can prevent and correspondence to gas leaks and fire accidents at LPG/CNG charging stations. The dual type sensor module has the function of collecting and transmitting the measured data to the sensors of methane, butane and hydrogen through RF433Mhz communication. In addition, each sensor is attached with two to improve stability and accuracy. The integrated control system software detects real-time data of the devices measured by the sensors and it send to the PC and smart phone of manager. Therefore, if accident occurs, the manager can check the status of the charging station regardless of time and place.

A Stydy On Hydrogen Quality International Standards Trend and Countermeasure (수소품질 국제 표준화 동향 및 대응기술에 관한 연구)

  • Lee, Taeck-Hong;Cheon, Young-Ki
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.454-460
    • /
    • 2006
  • In the production of hydrogen from various sources like cracking of LPG, LNG, Crude oil, or alkaline water electrolysis, the things that we keep in mind is the entrapment of unexpected impurities in the stream of produced $H_2$. If it is true that we are not able to produce 100% pure $H_2$, then subsequent procedure is the elimination of the impurities and the determination of the concentrations of each constituents in $H_2$ stream. By the way, each country has different constituents in its fuels and unavoidablely it was cost/economy debates between coutries. Thus, in this paper, our goal is to provide current international issues for hydrogen production.

Cu/ZnO sorbents for the hydrogen station (수소스테이션을 위한 Cu/ZnO 계 탈황제)

  • Jun, ki-Won;Bae, Jong-Wook;Kang, Suk-Hwan;Yoon, Young-Seek;Kim, Myung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.344-347
    • /
    • 2006
  • 탄화수소 연료(LNG, LPG)를 개질하여 수소를 제조하는 연료 처리 공정 중, 탈황 기술은 촉매의 활성저하 및 전극의 피독을 방지하기 위한 필수 기술이다. 본 연구에서는 도시가스 및 액화석유 가스용 부취제로 사용되는 유기 황화합물(,DMS, THT, TBM)을 제거하기 위한 탈황제로서 Cu/ZnO계 흡착제를 개발하였다. 공침법을 이용하여 흡착제를 제조하여 각 부취제별로 상온 및 고온에서의 흡착탈황 성능을 조사하였으며 또한, 이의 특성분석을 행하였다. $Cu/ZnO/Al_2O_3$ 탈황제는 메탄으로부터 고온에서 TH, DMS, TBM+THT 등의 황화합물들을 매우 효과적으로 제거할 수 있었다. 특히, TBM+THT의 혼합가스에서 TBM에 대해 선택적인 흡착을 보였다. THT 흡착에서 흡착온도가 $300^{\circ}C$ 이상에서는, 흡착과정 동안 황의 상호작용으로 인해 금속황화물이 생성되었다.

  • PDF