• Title/Summary/Keyword: 수소 발생기

Search Result 326, Processing Time 0.027 seconds

Contributive Estimation of Polycyclic Aromatic Hydrocarbons by Emission Source in Seoul Area (서울지역 대기 중 다환방향족탄화수소의 발생원별 기여도 평가)

  • Park, Chan-Koo;Yun, Joong-Sup;Eo, Soo-Mi;Shin, Jeong-Sik;Kim, Min-Young;Sohn, Jong-Ryeul;Mo, Sae-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.287-295
    • /
    • 2006
  • PAHs (Polycyclic Aromatic Hydrocarbons), one of the carcinogenic materials in environment, were investigated in this study. The standardized analysis conditions were tested, and then various factors which affect to the ambient PAHs concentration in Seoul were estimated. Moreover, the emissions of PAHs from major stationary sources were investigated to determine the quantitative relationships between ambient PAHs concentrations and emission sources. From the factor analysis, three factors relevant to the ambient PAHs in Seoul were found. Factor 1 was related to the concentrations of chrysene, pyrene, indeno (1, 2, 3-cd)pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo prerylene which were mainly emitted from gasoline and diesel fueled cars. Factor 2 showed higher loadings in phenanthrene and anthracene which were due to LNG and BC oil combustion in industry and home. And factor 3 included dibenz(a, h)anthracene and acenaphthene which were emitted from open burning and municipal solid waste incineration. Conclusively, all of three factors were consisted in 82% of total variance. The contribution of mobile sources in ambient air in Seoul was estimated at 64%, that of industrial and home sources at 17%, and that of open burning and municipal incineration at 1%.

Study for Oil Spill Source Identification by Comprehensive Two Dimensional Gas Chromatography (2차원 가스크로마토그래프를 이용한 해상유출유 감식기법 연구)

  • Lee, Y.S.;Lee, S.J.;Kim, C.S.;Oh, H.J.;Kim, H.G.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.169-174
    • /
    • 2006
  • A distinctive difference of hydrocarbon in crude oil and petroleum products exists. Depending on the origin where it comes from, crude oil shows its own unique pattern which is different from petroleum products containing characteristics according to their operating process and production period. A process of mixing behavior in a tank containing residual amounts of oil draws its own pattern when analysis is conducted. The analytical process described above is named oil fingerprint method. This study investigates an effectiveness of the method for comparing data sets produced by conventional gas chromatography with mass spectrometer (GC/MS) and comprehensive two-dimensional gas chromatography (GC X GC) which is known as powerful new technology for chemical analysis.

  • PDF

Evaluation of Concentration Polarization at Feed in the Permeation of VOCs/$N_2$ mixtures through PDMS membrane (VOCs/질소 혼합물 증기투과시 공급액부 경계층에서의 농도분극 분석을 위한 모델식 확립)

  • 염충균;이상학;최정환;이정민
    • Membrane Journal
    • /
    • v.11 no.2
    • /
    • pp.74-82
    • /
    • 2001
  • By using a phenomenological approach, model equations incorporating the resistance-in¬series concept were established to evaluate quantitatively concentration polarization in the boundary layer in feed adjacent to the membrane surface in the vapor permeation and separation of volatile organic compounds (VOCS)/$N_2$ mixture through po]y(dimethylsiloxane) (PDMS) membrane. The vapor permeations of various VOCS/$N_2$ mixtures through PDMS membrane were carried out at various feed flow rates. Chlorinated hydrocarbons, such as, methylene chloride, chlorofonn, 1,2-clichloroethane and 1,1,2-trichloroethane were used as organic vapor. By fitting the model equations to the experimental penneation data. the model parameters were detennined. respectively. Both the mass transfer coefficient of VOC across tbe boundary layer and concentration polarization modulus as a measure of the extent of concentration polarization were eitimated Quantitatively by the mooe1 equations with the determined model parameters. From the analysis on the detennined model parameters, the boundary layer resistance due to the concentration polarization of VOCs component was found to be more significant when the condensability of voe was greater. This study seeks to emphasize the importance of the boundary resistance on the vapor penneation of the vapor/gas mixtures with high permeability and high selectivity towards the minor component VOC.

  • PDF

Chemical Vapor Deposition of Tungsten by Silane Reduction (사일린 환원반응에 의한 텅스텐 박막의 화학증착)

  • Hwang, Sung-Bo;Choi, Kyeong-Keun;Rhee Shi-Woo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.10
    • /
    • pp.113-123
    • /
    • 1990
  • Tungsten film was deposited on the single crystal silicon wafer in a low pressure chemical vapor deposition reactor from silane and tungsten hexafluoride in the temperature range of $250-400^{\circ}C$ Deposition rate was found to be determined by the mass transfer rate of reactants from the gas phase to the safter surface. It was found out that tungsten films deposited contained about 3 atomic $\%$ of silicon and that the crystallinity and the grain size increased as the deposition temperature was increased. The resistivity of the film was measured to be in the range of $7~25{\mu}{\Omega}-cm$ and decreased with increasing deposition temperature. The adhesion of the tungsten film on a silicon surface was measured by the tape peel off test and it was improved with increasing deposition temperature. From the analysis of the gas composition, the reaction pathway to form $SiF_{4}$ and $H_{2}$ was found to be more favorable than HF formation.

  • PDF

Preparation of Synthesis Gas from Methane in a Capacitive rf Discharge (용량성 rf 플라즈마를 이용한 메탄으로부터의 합성가스 제조)

  • Song, Hyung Keun;Choi, Jae-Wook;Lee, Hwaung;Kim, Seung-Soo;Na, Byung-Ki
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.138-144
    • /
    • 2006
  • Conversion of methane to synthesis gas in a capacitive rf plasma at low pressure was experimentally studied. In this plasma, electrons which had sufficient energy-level collided with the molecules of methane or oxygen-containing gas, which were than activated and converted to synthesis gas. The effect of input power, various oxygen-containing gas and composition of the gas mixture were investigated. The conversion of methane reached up to 100%. In all cases, hydrogen and carbon oxide were produced as primary products, and other compounds was generated. The conversion of methane and the yield of hydrogen and carbon oxides were increased with increasing the input power. Depending on the oxygen-containing gases, the composition of synthesis gas was varied.

  • PDF

Secondary Ion Man Spectrometry: Theory rind Applications in Geosciences (이차이온질량분석기의 원리와 지질학적 응용)

  • 최변각
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.222-232
    • /
    • 2001
  • Secondary ion mass spectrometry (SIMS) uses focused high-speed primary ions to produce secondary ions from sample surface that are analyzed through a mass filter. SIMS is often called as ion microprobe, since it offers a micrometer-scale spatial resolution. Although the precision and accuracy of SIMS are not as good as many conventional mass spectrometers, it has several advantages such as small sample-size requirement, high spatial resolution and capability of in-situ analysis. In the field of geochemistry/cosmochemistry, SIMS is widely used for (1) stable isotope geochemistry of H, C, O, S, etc., (2) geochronology of U/Th-bearing minerals, (3) lateral distribution of trace elements in a mineral, and (4) discovery of presolar grains and investigation of their isotopic compositions.

  • PDF

The co-effect of $TiO_2$, Cu and Ni Powders for Enhancing the Hydrogen Generation Efficiency using Plasma Technology (플라즈마 반응기의 수소발생에 미치는 $TiO_2$, Cu, Ni 촉매제 영향)

  • Park, Jae-Yoon;Kim, Jong-Suk;Jung, Jang-Gun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1599-1605
    • /
    • 2008
  • The research was conducted in order to improve the hydrogen generation efficiency of the electrical plasma technology from tap water by using $TiO_2$ photocatalyst, mixed Cu - $TiO_2$ powder, and mixed Ni - $TiO_2$ powder as the catalysts. Experiments were performed with the pulsed power and nitrogen carrier gas. The result has shown that the hydrogen concentration with the presence of $TiO_2$ powder was created higher than that of without using photocatalyst. The hydrogen concentration with using $TiO_2$ was 3012ppm corresponding to the applied voltage of 16kV, while it without using the $TiO_2$ was 1464ppm at the same condition . The effect of $TiO_2$ powder was strongly detected at the applied voltages of 15kV and 16kV. This phenomena might be resulted from the co-effect of the pulsed power discharge and the activated state of $TiO_2$ photocatalyst. The co-effect of the mixed catalysts such as Cu-$TiO_2$ and Ni-$TiO_2$ (the mixed photocatalyst $TiO_2$ and transition metals) were also investigated. The experimental results showed that, Cu and Ni powder dopants were greatly enhancing the activity of the $TiO_2$ photocatalyst. Under these experimental conditions the extremely high hydrogen concentrations at the optimal point were produced as 4089ppm and 6630ppm, respectively.

Study on HFC-134a Hydrate Formation Rate : according to stirring speed and driving force (HFC-134a 하이드레이트의 형성속도에 관한 연구 : stirring speed, driving force 조건에 따라)

  • Shin, Hyung-Joon;Moon, Dong-Hyun;Seok, Ming-Wang;Lee, Gang-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.554-554
    • /
    • 2009
  • 지구온난화는 범지구적 환경문제로 매우 빠른 속도로 진행되면서 그 심각성을 더해가고 있다. 특히 해수면 상승이나 대형 태풍, 홍수, 가뭄 등의 이상기후가 빈번하게 발생되며 생태계에도 심각한 타격을 주고 있다. 이러한 지구온난화를 유발하는 물질들에 대해 도쿄의정서(Annex A)에 6대 온실가스($CO_2$ (이산화탄소), 메탄($CH_4$), $N_2O$(아산화질소), PFC(불화탄소), HFC(수소화불화탄소), $SF_6$(육불화황))로 정의 하여 규제대상으로 분류하고 있다. $CO_2$를 제외한 Non-$CO_2$ 온실가스들은 배출량이 $CO_2$에 비해 매우 낮지만 GWP(지구온난화지수)가 매우 커 지구온난화에 미치는 영향이 상당하다. 최근 이산화탄소 이외에 지구온난화 문제를 일으키는 온실가스에 대한 많은 관심으로 대상가스의 처리 또는 재활용을 위한 신기술 및 신공정 개발에 박차를 가하고 있다. 온실가스 중 HFCs는 GWP가 1300으로 미량의 배출로도 심각한 기후변화를 일으킬 수 있는 물질로, 우리나라의 경우 1990년 이후 HFCs 배출량 증가율은 연 평균 4.9% ~ 13.8%이다. 국내외 온실가스 처리기술은 대부분 CO2에 대한 연구개발 및 실증화가 지배적이고, non-CO2에 대한 처리기술 개발수준은 미흡할 뿐만 아니라 본 연구 대상인 HFCs 의 경우에는 처리기술 연구개발이 전무하다. 특히 HFCs는 냉매 또는 발포제로 사용되는데 일반적으로 사용 후 특별한 처리과정 없이 대기중으로 배출된다. 본 연구에서는 non-CO2 가스인 HFC-134a 를 대상으로 혼합가스에서 분리 회수를 위해 하이드레이트 기술을 접목시켜 경제적, 친환경적인 기술개발을 목적으로 한다. kinetic 반응장치와 고압반응기 및 magnetic drive system 을 이용하여 stirring speed와 driving force에 따른 HFC-134a 하이드레이트 형성속도의 상관관계를 제시하고자 한다.

  • PDF

Experimental Study on Combustion Instability Characteristics of Model Gas Turbine Combustor at Various H2/CH4/CO Composition (H2/CH4/CO 연료조성 변화에 따른 모형 가스터빈 연소기 불안정 특성에 대한 실험적 연구)

  • Yoon, Jisu;Lee, Min-Chul;Joo, Seongpil;Kim, Jeongjin;Yoon, Youngbin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.67-74
    • /
    • 2013
  • IGCC(Integrated Gasification Combined Cycle) system is candidates which can solve the environmental problems including global warming, since it can be easily combined with CCS(Carbon Capture System). In this research, combustion instability characteristics were studied at various fuel which are composed of $H_2/CH_4/CO$ mixture. Mode analysis for instabilities observed experimentally was conducted and the linearly increasing tendency of frequency was observed as the hydrogen content in fuel increases.

Study on the Density and Volume Change Property of Petroleum Products according to Temperature Variation (석유제품의 온도 변화에 따른 밀도 및 부피 변화 특성 연구)

  • Hwang, In-ha;Doe, Jin-woo;Kang, Hyung-kyu;Sung, Sang-rae;Ha, Jong-han;Na, Byung-ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.1112-1120
    • /
    • 2017
  • Petroleum products are composed of various types of hydrocarbon compounds. Like other types of liquids, they presented the variation of density and volume according to temperature change. The method of measuring the density of petroleum products in a liquid phase is based on experimental data obtained mainly for each fractionally distilled petroleum product. In this study, the density and volume changes of kerosene and automotive diesel according to temperature change were measured and the property of change were analyzed. The conversion values were calculated using the density volume conversion table proposed by international standard ASTM. In addition, we analyzed the differences between the reference values and the measured values for the temperature changes specified in the domestic metering law.