• Title/Summary/Keyword: 수분확산

Search Result 214, Processing Time 0.026 seconds

A Study on the Early Response System Subway Cabin Arson Fire (지하철 차량 방화사고 초기대응에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu;Kim, Si-Gon
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.21-30
    • /
    • 2006
  • Since Daegu subway arson fire disaster in 2003, there have been several copycat crimes such as at Seoul Metro line number seven and Hongkong Chuiwan line cases. Oil and gas were used for fire propagation in most cases as in Daegu case and such fire could be expanded to a whole subway cabin within several minutes. The fire may eventually cause the whole subway system stop. Fire damage can be minimized when fire occurrence and diffusion are blocked by stages or isolated rapidly. This study suggests an effective early response system that separates passengers from fire and a real-time fire extinguishment program by stages. Based on the subway arson case studies, the early response scenario has been structured by three stages, i.e., confirmation of fire and damage, early fire extinguishment, and information dissemination and passengers evacuation.

화학증착법으로 제조한 실리카/알루미나 복합막의 기체분리특성과 stability에 관한 연구

  • 김성일;하홍용;남석우;홍성안;김인원
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04b
    • /
    • pp.27-28
    • /
    • 1997
  • 최근 들어 분리공정의 발달과 산업의 고도화에 따라 기체 및 액체분리의 중요성이 강조되면서 열적, 화학적 그리고 기계적 안정성이 좋으며, 수명이 길고, 세척과 재생이 용이하며, 미생물에 의한 손상이 없는 무기막에 대한 연구가 진행중이다. 무기막은 기공의 크기에 따라 크게 다공성 막과 비다공성 막의 두 종류로 구분된다. 비다공성 금속막은 특정 기체에만 투과성을 가지며, 이때 기체는 용해-확산(solution-diffusion)기구에 의해 금속막을 투과하므로 특정기체에 대한 선택도는 매우 크나 투과도가 매우 작고 가격이 비싼 단점을 가지고 있다. 다공성 막은 기체 투과율이 큰 반면 기체 선택도가 작은 단점을 가지고 있다. 현재 기체분리에 사용되고 있는 무기막은 기공크기가 40${\AA}$ 이상으로 기체 분리가 Kundsen diffusion에 의해 이루어지므로, 기체 투과도는 큰 반면에 기체에 대한 선택도는 그리 크지 않다. 따라서 최근 들어서는 다공성 담체에 기공이 작은 ($d_{pore}<20{\AA}$)박막을 담지시켜 기체의 분리 선택도를 향상시키기 위한 연구가 활발히 이루어지고 있다. 본 연구에서는 유기금속 화학증착법(metal-organic chemical vapor deposition:MOCVD)을 이용하여 수소 선택성을 가지는 $SiO_2/Al_2O_3$ 복합막을 비율별로 제조하여 증착속도를 알아보고, 열과 수분에 노출시켜 박막의 기체투과도 변화를 살펴보았다.

  • PDF

Moire Interferometry Measurement and Numerical Analysis for Hygroscopic Swelling of Al-Polymer Joint (Al-Polymer 접합체의 흡습팽창에 대한 모아레 간섭 측정 및 수치해석)

  • Kim, Kibum;Kim, Yong-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3442-3447
    • /
    • 2014
  • A simple method to evaluate the hygroscopic characteristics of polymer of microelectronic plastic package is suggested. To evaluate the characteristics, specimens were prepared, and the internally absorbed moisture masses were measured as a function of the absorbing time and calculated numerically. The hygroscopic pressure ratio was calculated by heat transfer analysis supported by commercial FEM code because the hygroscopic diffusion equation has the same form as the heat transfer equation. The moisture masses were then summed by the self developed code. The nonconductive polymers had quite different characteristics for the different lots, even though they were the same products. The absorbed moisture mass variations were calculated for several different characteristics, and the optimal curve of the mass variation close to experimental data was selected, whose solubility and diffusivity were affected by the hygroscopic characteristics of the material. The method can be useful in the industrial fields to quickly characterize the polymer material of the semiconductor package because the fast correspondence is normally required in industry. The weight changes in the aluminum-nonconductive-polymer joint due to moisture absorption were measured. The deformed system was also measured using the Moire Interferometry system and compared with the results of finite element analysis.

Adsorption Characteristics of Flue Gas Components on Zeolite 13X and Effects of Impurity (제올라이트 13X에 의한 배가스 성분의 흡착 특성 및 불순물의 영향)

  • Suh, Sung-Sup;Lee, Ho-Jin
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.838-846
    • /
    • 2016
  • Most of combustion processess used in industries require recovering or removing flue gas components. Recently a new MBA (moving bed adsorption) process for recovering $CO_2$ using zeolite 13X was developed. In this study, adsorption experiments for carbon dioxide, nitrogen, sulfur dioxide, and water vapor on zeolite 13X were carried out. Adsorption equilibrium and adsorption rate into solid particle were investigated. Langmuir, Toth, and Freundlich isotherm parameters were calculated from the experiment data at various temperatures. Experimental results were consistent with the theoretically predicted values. Also $CO_2$ adsorption amount was measured under the conditions with impurities such as $SO_2$ and $H_2O$. Binary adsorption data were well fitted to the extended Langmuir isotherm using parameters obtained from pure component experiment. However, $H_2O$ impurity less than, roughly, ${\sim}10^{-5}H_2O\;mol/g$ zeolite 13X enhanced slightly $CO_2$ adsorption. Spherical particle diffusion model well described experimentally measured adsorption rate. Diffusion coefficients and activation energies of $CO_2$, $SO_2$, $N_2$, $H_2O$ were obtained. Diffusion coefficients of $CO_2$ and $SO_2$ decreased with small amount of preadsorbed impurity. Parameter values from this study will be helpful to design of real commercial adsorption process.

Analysis for Rainfall Infiltration Using Electrical Resistivity Monitoring Survey (강우 침투 특성 분석을 위한 전기비저항 모니터링 탐사)

  • Kim, Sung-Wook;Choi, Eun-Kyeong;Park, Dug-Keun;Yoon, Yeo-Jin;Lee, Kyu-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.7
    • /
    • pp.41-53
    • /
    • 2012
  • During rainfall period, to identify the characteristics of the infiltration of moisture, electrical resistivity monitering survey was carried out to weathered zone. Four regions of geophysical exploration areas with different rock types, four regions were selected. An area consists of mafic granite and three areas are composed of sedimentary rocks (Sandstone, Shale, Unconsolidated Mudstone). Survey was conducted from June (rainy season) to November (dry season), and during the period the change in resistivity was observed. According to the result of monitoring exploration on Geumjeong and Jinju areas, for the estimation of the standard rainfall, it is necessary to estimate the effects of the antecedent rainfall during the rainy season based on the overall rainfall from June till October and also necessary to consider this for the estimation of the half period. Also, the vertical distribution of the low resistivity anomaly zone does not show that the infiltration of moisture does not occur uniformly from the surface of the ground to the lower ground but shows that it occurs along the relaxed gap of the crack or soil stratum of the weathering zone. In Pohang area, the type of moisture infiltration is different from that of the granite or sedimentary rock. Since, after the rainfall, the rate of infiltration to the lower ground is high and the period of cultivation to the lower bedrock aquifer is short, it has similar effect to that of the antecedent rainfall applied for the estimation of the standard rainfall being presently used. In Danyang, due to the degree of water content of the ground, the duration period of the low resistivity anomaly zone observed in the lower ground of the place where clastic sedimentary rock is distributed is similar to that in Pohang area. The degree of lateral water diffusion at the time of localized heavy rain is the same as that of the sedimentary rock in Jinju. According to the above analysis results, in Danyang area, the period when the antecedent rainfall has its influence is estimated as three weeks or so.

Soil Physiochemical Properties in Leaf-yellowing Black Locust (Robinia Pseudo-acacia L.) Stands (아까시나무 황화현상 발생임분의 토양 이화학적 특성)

  • Lee, Seung-Woo;Byun, Jae-Kyoung;Ji, Dong-Hun;Kwon, Young-Dae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.6
    • /
    • pp.409-414
    • /
    • 2009
  • In 1970's Black locust(Robinia pseudoacacia) had been widely planted Korea as an important forest greening species for erosion control afforestation. Since 2000, however, the tree's leaf-yellowing symptom has often been observed at a limited region and then spreaded out over the country in 2006. This study was conducted to study soil physiochemical properties of black locust stands with and without the leaf-yellowing symptom in Osan, Gyeonggi province. Most of soils in sampling sites were mostly slightly eroded, dry, and moderately dry. Available soil depth(16cm) and total soil depth(26cm) in leaf-yellowing (LY) site were significantly lower than in non leaf-yellowing (Non-LY) site's soil depths which were 30cm and 56cm, respectively. And solid phase proportion and bulk density in soils were lower in LY site than in non-LY site soils, while soil liquid phase proportion was also low. It could reflect that LY site soils might have a lower air and moisture movement in the rhizosphere of black locust stand compared with non-LY site soils. Soil acidity in both sites was very strong acid, soil pH (4.42) of LY site was slightly lower than non-LY site's (pH 4.54). Content of available phosphorous, exchangeable $Ca^{2+}$ and $Mg^{2+}$ and percent base saturation were less than LY site. These results indicated that soil physiochemical condition in LY site, more deteriorated than non-LY site, should adversely affect the retention and supply capacity of soil nutrients and moisture. Therefore the black locust may be more sensitive to other environmental stresses.

Sea Cucumber (Stichopus japonicus) Grading System Based on Morphological Features during Rehydration Process (수화 시의 형태학적 특징에 따른 건해삼의 등급 분류 시스템 개발)

  • Lee, Choong Uk;Yoon, Won Byong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.3
    • /
    • pp.374-380
    • /
    • 2017
  • Image analysis and k-mean clustering were conducted to develop a grading system of dried sea cucumber (SC) based on rehydration rate. The SC images were obtained by taking pictures in a box under controlled light conditions. The region of interest was extracted to depict the shape of the SC in a 2D graph, and those 2D shapes were rendered to build a 3D model. The results from the image analysis provided the morphological features of the SC, including length, width, surface area, and volume, to obtain the parameters of the k-mean clustering weight. The k-mean clustering classified the SC samples into three different grades. Each SC sample was rehydrated at $30^{\circ}C$ for 40 h. During rehydration, the flux of each grade was analyzed. Our study demonstrates that the mass transfer rate of SC increased as the surface area increased, and the grade of SC was classified based on rehydration rate. This study suggests that the optimal rehydration process for SC can be achieved by applying a suitable grading system.

A Study on the Spatial Information and Location Environment of Dead Coniferous Tree in Subalpine Zone in Jirisan National Park -Focus on Korean Fir(Abies koreana) in Banyabong, Yeongsinbong, Cheonwangbong- (지리산국립공원 아고산대 침엽수 고사개체 공간정보 구축 및 입지환경 분석 - 반야봉, 영신봉, 천왕봉 일원 구상나무를 중심으로-)

  • Park, Hong Chul;Moon, Geon Soo;Lee, Ho;Lee, Na Yeon
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.1
    • /
    • pp.42-54
    • /
    • 2020
  • This study aimed to analyze the rate of increase and spread patterns of dead trees of the conifer (Abies koreana and others) in subalpine zones by using the high-resolution aerial images in Jirisan National Park around 10 years ago. Furthermore, factors affecting the death of conifer were identified by analyzing the altitude, topographical information, solar radiation, and moisture environment of the site where the dead trees are located. The number of dead trees per unit area increased by two to five times in the Banyabong peak, Yeongsinbong peak, and Cheonwangbong peak in Jirisan National Park over the past decade. The increase was about 2 times in the Banyabong peak, about 3.9 times in the Yeongsinbong peak, and about 5.2 times in the Cheonwangbong peak, indicating the most notable increase in the Cheonwangbong peak. It is estimated that dead trees commonly occurred in the environments where the soil moisture content was low due to the high slope, amount of evaporation was high due to strong solar radiation as the location faced south, and the soil was dry due to strong solar radiation and short rain retention time. In other words, dead conifer trees in subalpine zones were concentrated in dry location environments, and the tendency was the same more than ten years ago.

Studies on Predicting the Kiln Drying Time and Moisture Content of Board and Dimension Lumber of Pinus densiflora using an Internal Moisture Diffusion Model of Softwood (침엽수재(針葉樹材)의 수분확산(水分擴散)모델을 이용(利用)한 소나무판재(板材)와 평소각재(平小角材)의 열기건조(熱氣乾燥) 시간(時間)과 함수율(含水率) 추정(推定)에 관(關)한 연구(硏究))

  • Lee, Sang-Bong;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.67-81
    • /
    • 1989
  • This experiment was carried out to know the mothod of changing the step of moisture content schedule with time in conventional kiln drying. For the purpose of this object. we made drying model by applying the moisture diffusion model by J.FSiau(1984) to average moisture content equation by J.Crank(1956) derived it from Fick's second law. And to verify this method of drying model. 2.5cm-thick boards and 5.0cm-thick dimension lumbers of Pinus densiflora were kiln-dried with the schedule of T11-C3 and T10-C4, respectively. And then the drying rates were investigated and compared with those calculated from drying model. The results obtained were as follows 1. Average drying rate and total drying time of board to dry to 6.5% moisture content were 0.64%/hr and 109hr., and those of dimension lumber to dry to 8.3% moisture content were 0.4%/hr. and 162hr., respectively. 2. The moisture content of shell and core decreased by equalizing treatment and increased by conditioning treatment both on board and dimension lumber. But the moisture gradient was lower after conditioning than after equalizing. 3. As the drying was proceeded, the transverse bound water diffusion coefficient all but linearly decreased, the water vapor diffusion coefficient abruptly curvilinearly increased, while the transverse diffusion coefficient curvilinearly decreased both on board and dimension lumber. But each of diffusion coefficients on board was larger than that on dimension lumber. 4. Compared to experimential drying rate of board. theoretical drying rate was larger at 30.0%-21.8% moisture content range and was similiar at 21.8%-5.4% moisture content. And in case of dimension lumber, the drying rate was similiar at 30.0%-16.1% moisture content range but theoretical drying rate was much lower at 16.1%-8.3% moisture content range. 5. The possibility of adapting this drying model to changing the moisture content schedule step with time was in the range of 21.8%-5.4% moisture content on board. And in the case of dimension lumber that was in the range of 30.0%-16.1% moisture content.

  • PDF

Effect of Current Density on Ion Conductivity of Membrane in Proton Exchange Membrane (고분자전해질 연료전지에서 고분자막의 이온전도도에 미치는 전류밀도의 영향)

  • Hwang, Byungchan;Oh, Sohyung;Lee, Daewoong;Chung, Hoi-Bum;You, Seung-Eul;Ku, Young-Mo;Na, Il-Chae;Lee, Jung-Hoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.1-5
    • /
    • 2018
  • In this work, we study the ion conductivity by analyzing the impedance to the high current density range that the PEMFC (Proton Exchange Membrane Fuel Cell) is actually operated. The effect of GDL (Gas Diffusion Layer)presence on impedance was investigated indirectly by measuring hydrogen permeability. When the RH (Relative Humidity)was higher than 60% in the low current range (< $80mA/cm^2$), the moisture content of the polymer membrane was sufficient and the ion conductivity of the membrane was not influenced by the current change. However, when RH was low, ion conductivity increased due to water production as current density increased. The ion conductivity of the membrane obtained by HFR (High Frequency Resistance) in the high current region ($100{\sim}800mA/cm^2$)was compared with the measured value and simulated value. At RH 100%, both experimental and simulated values showed constant ion conductivity without being influenced by current change. At 30~70% of RH, the ionic conductivity increased with increasing current density and tended to be constant.