• Title/Summary/Keyword: 수복물

Search Result 736, Processing Time 0.02 seconds

Practicality and prospect of full-zirconia restoration (풀지르코니아 수복물의 실용성과 전망)

  • Hwang, Jung-Won
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.2
    • /
    • pp.101-121
    • /
    • 2015
  • Zirconia polycrystalline (Y-TZP) showed better mechanical properties and superior resistance to fracture than other conventional dental ceramics. Zirconia-based ceramics have been successfully introduced into the clinic to fabricate fixed dental prostheses (FDPs), along with a dental computer-aided/computer-aided manufacturing (CAD/CAM) system. It has been clinically available as an alternative to the metal framework for fixed dental prostheses (FDPs). The most frequent clinical complication with zirconia-based FDPs was chipping of the veneering porcelain that was affected by many factors. Another option was full-contour zirconia FDPs using high translucent zirconia. Full-contour zirconia FDPs has many clinical advantages but it caused concern about the wear of antagonist enamel, because the hardness of Y-TZP was over double that of porcelain. However, many articles demonstrates that highly polished zirconia yielded lower antagonist wear compared with porcelains. In this article (1) advantages of full zirconia restorations, (2) clinical applications of zirconia restorations, (3) abutment preparation, (4) surface finish of zirconia restoration and antagonist enamel wear, (5) bond of zirconia with resin-based luting agents, (6) communication in clinical & lab.procedures for full zirconia restorations are reviewed.

Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study (단일 수복물과 3본 고정성 수복물 지대치 모델에서 삼차원 분석을 통한 구강 스캐너의 정확도 비교)

  • Huang, Mei-Yang;Son, Keunbada;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.102-109
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. Materials and methods: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (${\alpha}=.05$). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. Results: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). Conclusion: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.

MOUTHGUARD FOR RELIEF OF REPEATED CLENCHING STRESS TO CERVICAL RESTORATIONS DURING EXERCISES (운동시의 습관적인 이 악물기가 치경부 수복물에 가해지는 스트레스를 분산하기 위한 마우스가드의 사용)

  • Yoon, Sung-Young;Song, Chang-Kyu;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.1
    • /
    • pp.20-23
    • /
    • 2010
  • Mouthguards were used to protect boxers from lip lacerations and other soft tissue injuries in the late 19th century. Now they are used various parts of dental treatment, which are sports protective aid, bleaching tray, orthodontic retainer, implant insertion guide tray, splint and so on. Repeated dislodgement of Class V restoration due to habitual clenching stress should be restored with stress control. Mouthguard can be used as stress relief device. This case describes methods that can relieve occlusal force to teeth by using mouthguard. Satisfactory results can be obtained by using mouthguard for retention of repeated dislodgement Class V restorations. If patients suffered from repeated restorations of Class V due to clenching, mouthguard can be used additional device to relieve the occlusal stress in conservative dentistry.

EFFECT OF RESTORATION TYPE ON THE STRESS DISTRIBUTION OF ENDODONTICALLY TREATED MAXILLARY PREMOLARS; THREE-DIMENSIONAL FINITE ELEMENT STUDY (수복물의 종류가 근관치료된 상악 제2소구치의 응력분포에 미치는 영향: 3차원 유한요소법적 연구)

  • Jung, Heun-Sook;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.8-19
    • /
    • 2009
  • The purpose of this study was to investigate the effects of four restorative materials under various occlusal loading conditions on the stress distribution at the CEJ of buccal. palatal surface and central groove of occlusal surface of endodontically treated maxillary second premolar, using a 3D finte element analysis. A 3D finite element model of human maxillary second premolar was endodontically treated. After endodontic treatment, access cavity was filled with Amalgam, resin, ceramic or gold of different mechanical properties. A static 500N forces were applied at the buccal (Load-1) and palatal cusp (Load-2) and a static 170N forces were applied at the mesial marginal ridge and palatal cusp simultaneously as centric occlusion (Load-3). Under 3-type Loading condition, the value of tensile stress was analyzed after 4-type restoration at the CEJ of buccal and palatal surface and central groove of occlusal surface Excessive high tensile stresses were observed along the palatal CEJ in Load-1 case and buccal CEJ in Load-2 in all of the restorations. There was no difference in magnitude of stress in relation to the type of restorations. Heavy tensile stress concentrations were observed around the loading point and along the central groove of occlusal surface in all of the restorations. There was slight difference in magnitude of stress between different types of restorations. High tensile stress concentrations around the loading points were observed and there was no difference in magnitude of stress between different types of restorations in Load-3.

Effect of machining precision of single ceramic restorations on the marginal and internal fit (단일 도재 수복물의 가공 정밀도가 변연 및 내면 적합도에 미치는 영향)

  • Son, Keunbada;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the machining precision and the marginal and internal fit of single restorations fabricated with three types of lithium disilicate ceramic blocks and to evaluate the correlation. Materials and methods: Single restorations were designed using a CAD software program. The crown designed model file was extracted from the CAD software program. Three types of lithium disilicate blocks (Rosetta; HASS, IPS e.max CAD; Ivoclar vivadent, VITA Suprinity; VITA) were milled using a milling machine. For the fabrication of the crown scanned model file, the intaglio surface of the restoration was digitized using a contact scanner. Then, using the three-dimensional inspection software (Geomagic control X; 3D Systems), the process of the overlap of the crown designed model and the scanned model and 3-dimensional analysis was conducted. In addition, the marginal and internal fit of the crowns was evaluated by a silicone replication method. The difference among three types of single ceramic crown was analyzed using a Kruskal-Wallis H test, and Spearman correlation analysis was performed to analyze the correlation between machining precision and fitness (α=.05). Results: There was a significant difference in the machining precision and the marginal and internal fit according to the type of ceramic block (P<.001). In addition, the machining precision and the marginal and internal fit were positively correlated (P<.001). Conclusion: The marginal fit of crowns fabricated according to the types of ceramic blocks was within the clinically acceptable range (< 120 ㎛), so it can be regarded as appropriate machining precision applicable to all clinical as aspects in terms of the marginal fit.

5급 와동의 심미 수복

  • Hwang, Seong-Uk
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.4-22
    • /
    • 2012
  • 치경부에 발생된 병소 부위(cervical lesion)는 "우식성 병소(caries lesion)"와 "비우식성 병소(non-caries lesion)"로 분류할 수 있다. 우식성 병소는 구강 내 세균들의 활동에 기인하여 발생된 병소로서 경조직 손상 부위의 수복과 함께 우식이 재발하지 않도록 체계적으로 대응하는 것이 필요하다. 비우식성 병소는 산성 물질, 저작력 및 이물질에 의한 마모 작용과 같은 다양한 원인에 의해 발생될 수 있으며, 수복 치료에 앞서 병소에 발생 원인을 규명하는 것이 중요하다. 먼저 병소 유발 원인에 대한 분석과 이에 대한 적절한 조치를 취한 후에 수복 치료를 시행하는 것이 바람직하다. 심미적인 요구가 높은 치경부 병소의 수복을 위하여 사용될 수 있는 재료는 "불소를 방출하는 재료"와 "불소를 방출하지 않는 재료"로 나뉘어지는데, 세균의 활동에 의해 형성된 우식성 병소의 수복에는 불소를 방출하는 재료를 사용하는 것이 추천된다. 우수한 심미성과 보다 강력한 유지력이 요구되는 경우에는 복합 레진계 수복 재료들을 사용하여 수복하게 되는데, 이 경우에는 "접착 술식(bonding procedure)"이 중요한 역할을 수행하게 된다. "접착 술식"은 수복물의 일차적인 유지 뿐 아니라 지각과민을 해소하고 2차 우식을 방지하며, 궁극적으로 수복물의 수명을 좌우하는 결정적인 역할을 수행한다. 자연 치아를 최대한 보존하고자 하는 "최소침습(minimum intervention)" 개념에 바탕을 두고 세심하게 형성된 와동에 각각의 증례에 최적화된 수복 재료를 선택하여 수복치료를 시행한다면 보다 심미적이고 환자가 편안한 치경부 수복물을 완성할 수 있을 것이다.

  • PDF

Aesthetic restoration n patients with unaesthetic maxillary anterior teeth using double scan : A case report (비심미적인 상악 전치부 환자에서 이중 스캔을 이용한 심미보철 수복 증례)

  • Ko, Chang Woo;Kim, Min-Ji;Yang, Hong-So;Park, Sang-Won;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.166-172
    • /
    • 2018
  • In case of the treatment of maxillary anterior teeth, it should be taken into account the proper morphology, arrangement and color satisfying patient's esthetic demands. For this purpose, facial composition, dentofacial composition, dental composition and dentogingival composition should be considered making diagnosis and treatment plan in an esthetic point of view. In adjustable temporary crown state, careful evaluation and correction of the esthetic and functional aspect were performed, and the definite restoration was reproduced using double scan.

복합레진 수복물의 예상되는 실패 원인과 예방책

  • 신동훈
    • Proceedings of the KACD Conference
    • /
    • 2002.05a
    • /
    • pp.351-351
    • /
    • 2002
  • 재료의 발달과 더불어 높은 임상 성공률을 보이는 복합레진 수복물의 예상 가능한 실패 양태를 분석하고 이를 방지하기 위한 요점들을 단계별로 요약하고자 한다.

  • PDF

Esthetic restoration using Digital Smile Design: a case report ('Digital Smile Design'을 이용한 심미수복증례)

  • Kim, Kwanghyun;Lee, Kyuho;Pae, Ahran;Noh, Kwantae;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.144-149
    • /
    • 2015
  • To achieve an esthetic restoration, visualized information considering the facial aspect of patient is required. As for the reasons of esthetic failure, it could be explained by lack of communication and information such as horizontal, vertical and esthetic line. Therefore, it is important to deliver that the visualized information to dental technicians or other dentists for the success of esthetic treatment. This case report presents the process of visualizing esthetic information and designing the restoration using a digital diagnostic tool; Digital Smile Design.

REPLACEMENT OF POSTERIOR RESTORATIONS (구치부 수복물의 재수복에 관한 연구)

  • Kim, Ji-Young;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.460-469
    • /
    • 2006
  • This article complies a survey on the replacement of the posterior restorations and accesses possible factors that influence the replacement of posterior restorations. The data was collected from patients that visited department of conservative dentistry from Dec 1st 2003, to Sep 3rd 2004. Teeth was restricted to posterior permanent teeth. 9 dentists recorded age, gender of patients, tooth location, cavity farm and restorative material. They rated marginal adaptation, anatomic form, secondary caries of old restoration by modified Ryge criteria system. The statistical analysis was performed with Chi square test (p < 0.05) for replacement ratio according to patients, tooth factor and One way ANOVA was performed for comparison of old restoration according to restorative material. The results were as follows; 1. The female (62%) was statistically higher ratio than the male (38%). 2. The distribution of replacement case according to age, the rate of replacement was in descending order, 20's (38.3%), 40's (16.8%), 30's (15.9%), 10's (11.1%), 50's (9.2%), 60's (8.7%). 3. The rate of replacement was 88% for molar and 12% for premolar (p $gt; 0.05). 4. The rate of replacement was 39% for maxillar and 61% for mandible (p $gt; 0.05). 5. The material of restorations was amalgam (69%), gold inlay (17%), composite resin (13%). 6. In rating system by modified Ryge criteria system on margin adaptation, there was statistically significant difference between amalgam and gold inlay. But on anatomic form and caries, there was no statistically significant difference among the material of restorations.