• Title/Summary/Keyword: 수면구조

Search Result 352, Processing Time 0.03 seconds

Influence of Fluid Height and Structure width ratio on the Dynamic Behavior of Fluid in a Rectangular Structure (사각형 구조물에 저장된 유체의 동적거동에 유체높이와 구조물 폭의 비가 미치는 영향)

  • Park, Gun;Yoon, Hyungchul;Hong, Ki Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.126-134
    • /
    • 2020
  • In the case of an earthquake, the fluid storage structure generates hydraulic pressure due to the fluctuation of the fluid. At this time, the hydraulic pressure of the fluid changes not only the peaked acceleration of the earthquake but also the sloshing height of the fluid free water surface. Factors influencing this change in load include the shape of the seismic wave, the maximum seismic strength, the size of the fluid storage structure, the width of the structure, and the height of the fluid. In this study, the effect of the ratio between the height of the fluid and the width of the structure was investigated on the fluctuation characteristics of the fluid. 200mm and 140mm of fluid were placed in a water storage tank with a width of 500mm, and a real seismic wave was applied to measure the shape of the fluctuation of the fluid free water surface. The similarity between the experiment and the analysis was verified through the S.P.H(Smoothed Particle Hydrodynamic) technique, one of the numerical analysis techniques. It was confirmed that the free water surface of the fluid showed a similar shape, through comparison of experiment and analysis. And based on this results, SPH technique was applied to analyze the fluctuation shape of the fluid free water surface while varying the ratio between the fluid height and the structure width. An equation to predict the maximum and minimum heights of the fluid free water surface during an earthquake was proposed, and it was confirmed that the error between the maximum and minimum heights of the fluid free water surface predicted by the proposed equation was within a maximum of 3%.

Optimization Design of Floating PV Structure for Back Surface Temperature of PV Module (PV모듈의 배면온도를 고려한 수상 태양광발전 부유구조물의 최적 설계)

  • Kim, Seok-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1088-1089
    • /
    • 2015
  • 본 논문에서는 태양광발전시스템의 발전 효율을 극대화하기 위한 태양전지 모듈의 배면온도를 낮출 수 있는 부유구조물의 최적화 설계에 대한 것이다. 저수지 수면은 태양에너지를 흡수하게 되면 물 온도의 상승으로 밀도저하가 발생되고 저수지의 수면이 최상층에 위치하여 지속적으로 태양에너지가 흡수는 경우 최상층의 수면온도가 $60^{\circ}C$ 이상 상승하게 된다. 이는 태양전지 모듈의 배면온도 상승을 주도하여 시스템 발전량의 감소원인으로 작용한다. 수상 태양광발전시스템의 효율 향상을 위해 태양전지 모듈의 온도 저하가 반드시 필요하고, 더불어 저수지 지리적 요건에 따른 바람의 영향 등을 고려한 태양광발전 부유구조물 최적 설계가 요구된다. 열전달 수치해석을 통해 태양광발전 구조물에 대한 최적설계, 태양전지 모듈의 온도 측정 및 성능 검증을 통해 태양광발전 구조물의 상하단의 높이의 최적 설계 조건을 확립하였다.

  • PDF

Gas Permeation Characteristics of Water-Casting Composite Membrane (수면전개 복합막의 기체투과 특성에 관한 연구)

  • Nam, Suk-Tae
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1992.10a
    • /
    • pp.49-52
    • /
    • 1992
  • 본 연구에서는 기체분리용 고분자 분리막을 박막화하기 위하여 기체의 선택도와 투과도가 서로 상이한 celluloseacetate(CA), polyvinylchloride(PVC) 및 polystyrene(PS) 등의 고분자용액을 사용하여 수면전개법에 수면 전개기구와 박막의 구조적 특성을 연구하였고, 또한 기체 분리막으로서의 이 수면전개막을 개발하기 위하여 CA, PVC, PS 단일 적층막, CA-PVC 복합적 층막, PVC/PS 혼합적층막의 형태로 제막하여 기체분리효과를 검토하였다.

  • PDF

Clinical Characteristic and Respiratory Disturbance Index as Correlates of Sleep Architecture in Obstructive Sleep Apnea Syndromes Diagnosed with Polysomnography (수면다원기록법으로 확진된 폐쇄성 수면무호흡증 환자의 임상특성, 그리고 호흡장애지수와 수면 구조간의 상관관계)

  • Kim, Seog-Joo;Park, Doo-Heum;Kim, Yong-Sik;Woo, Jong-Inn;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.2
    • /
    • pp.113-120
    • /
    • 2001
  • Objectives: Obstructive sleep apnea syndrome is common and may produce various symptoms and serious complications. A substantial number of research articles on obstructive sleep apnea syndrome have been published in Korea. However, we found such limitations as lack of sufficient sample size and lack of polysomnography-proven cases. Therefore, we aimed at studying clinical features and sleep structure in a sufficient number of Korean patients with obstructive sleep apnea syndrome diagnostically confirmed with polysomnography. Methods: We studied 801 subjects referred to the Division of Sleep Studies, Seoul National University Hospital, who were diagnosed as having obstructive sleep apnea syndrome with polysomnography. Subjects were excluded if they had central sleep apnea syndrome, periodic limb movement disorder, narcolepsy or REM sleep behavior disorder. Foreign patients were also excluded. First of all, we studied the clinical features of the subjects. Secondly, we compared sleep-related parameters of the study subjects with those of age/sex-matched normal values. Thirdly, correlations of respiratory disturbance index (RDI) with each of the sleep-related parameters were calculated. Results: Among the 801 subjects, 668 were male subjects (83.4%) and 133 female subjects (16.4%). Their mean age was 46.6 years (${\pm}13.5$). The mean body mass index (BMI) was 25.8 (${\pm}3.8$) and subjects with BMI was over 28.0 accounted for 22.8% of the total. Fifty subjects (6.2%) were found to take benzodiazepines. Mean RDI and mean nocturnal oxygen saturation of all subjects was 31.2 (${\pm}24.4$) and 94.5% (${\pm}3.6$), respectively. In comparison with normal values, the subjects showed longer sleep latency, lower sleep efficiency, decreased total slow wave sleep % (TSWS %), and decreased total REM sleep % (TREM %)(p<0.01 in all). RDI had a negative correlation with each TSWS % and TREM % (p<0.01, p<0.01). However, RDI did not have significant correlation with either sleep latency or sleep efficiency. Conclusion: In this study, 6.2% of patients diagnosed as having obstructive sleep apnea syndrome were found to take benzodiazepines, although they are generally considered to be of litte benefit or even dangerous because of the respiratory suppressing effect. The proportion of obese subjects was only 22.8% and Korean patients with obstructive sleep apnea syndrome seem to be less obese than those described in foreign journals. This study also suggests that the severity of obstructive sleep apnea syndrome may have a more significant effect on sleep architecture defined as TSWS % and TREM % than on sleep efficiency.

  • PDF

Correlational Analysis of Supine Position Time and Sleep-related Variables in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡 증후군에서 앙와위 자세시간과 수면관련변인 간 상관관계 분석)

  • Kim, Si Young;Park, Doo-Heum;Yu, Jaehak;Ryu, Seung-Ho;Ha, Ji-Hyeon
    • Sleep Medicine and Psychophysiology
    • /
    • v.24 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • Objectives: A supine sleep position increases sleep apneas compared to non-supine positions in obstructive sleep apnea syndrome (OSAS). However, supine position time (SPT) is not highly associated with apnea-hypopnea index (AHI) in OSAS. We evaluated the correlation among sleep-related variables and SPT in OSAS. Methods: A total of 365 men with OSAS were enrolled in this study. We analyzed how SPT was correlated with demographic data, sleep structure-related variables, OSAS-related variables and heart rate variability (HRV). Multiple linear regression analysis was conducted to investigate the factors that affected SPT. Results: SPT had the most significant correlation with total sleep time (TST ; r = 0.443, p < 0.001), followed by sleep efficiency (SE ; r = 0.300, p < 0.001). Snoring time (r = 0.238, p < 0.001), time at < 90% SpO2 (r = 0.188, p < 0.001), apnea-hypopnea index (AHI ; r = 0.180, p = 0.001) and oxygen desaturation index (ODI ; r = 0.149, p = 0.004) were significantly correlated with SPT. Multiple regression analysis revealed that TST (t = 7.781, p < 0.001), snoring time (t = 3.794, p < 0.001), AHI (t = 3.768, p < 0.001) and NN50 count (t = 1.993, p = 0.047) were associated with SPT. Conclusion: SPT was more highly associated with sleep structure-related parameters than OSAS-related variables. SPT was correlated with TST, SE, AHI, snoring time and NN50 count. This suggests that SPT is likely to be determined by sleep structure, HRV and the severity of OSAS.

Detrended Fluctuation Analysis of Sleep Electroencephalogram between Obstructive Sleep Apnea Syndrome and Normal Children (소아기 수면무호흡증 환자와 정상 대조군 수면 뇌파의 탈경향변동분석)

  • Kim, Eui-Joong;Ahn, Young-Min;Shin, Hong-Beom;Kim, Jong-Won
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.1
    • /
    • pp.41-49
    • /
    • 2010
  • Unlike the case of adult obstructive sleep apnea syndrome (OSAS), there was no consistent finding on the changes of sleep architecture in childhood OSAS. Further understanding of the sleep electroencephalogram (EEG) should be needed. Non-linear analysis of EEG is particularly useful in giving us a new perspective and in understanding the brain system. The objective of the current study is to compare the sleep architecture and the scaling exponent (${\alpha}$) from detrended fluctuation analysis (DFA) on sleep EEG between OSAS and normal children. Fifteen normal children (8 boys/7 girls, 6.0${\pm}4.3$2.2 years old) and twelve OSAS children (10 boys/2 girls, 6.4${\pm}4.3$3.4 years old) were studied with polysomnography (PSG). Sleep-related variables and OSAS severity indices were obtained. Scaling exponent of DFA were calculated from the EEG channels (C3/A2, C4/A1, O1/A2, and O2/A1), and compared between normal and OSAS children. No difference in sleep architecture was found between OSAS and normal controls except stage 1 sleep (%) and REM sleep latency (min). Stage 1 sleep (%) was significantly higher and REM latency was longer in OSAS group (9.3${\pm}4.3$4.3%, 181.5${\pm}4.3$59.9 min) than in controls (5.6${\pm}4.3$2.8%, 133.5${\pm}4.3$42.0 min). Scaling exponent (${\alpha}$) showed that sleep EEG of OSAS children also followed the 'longrange temporal correlation' characteristics. Value of ${\alpha}$ increased as sleep stages increased from stage 1 to stage 4. Value of ${\alpha}$ from C3/A2, C4/A1, O1/A2, O2/A1 were significantly lower in OSAS than in control (1.36${\pm}4.3$0.05 vs. 1.41${\pm}4.3$0.04, 1.37${\pm}4.3$0.04 vs. 1.41${\pm}4.3$0.04, 1.37${\pm}4.3$0.05 vs. 1.41${\pm}4.3$0.05, and 1.36${\pm}4.3$0.07 vs. 1.41${\pm}4.3$0.05, p<0.05). Higher stage 1 sleep (%) in OSAS children was consistent finding with OSAS adults. Lower $'{\alpha}'$ in OSAS children suggests decrease of self-organized criticality or the decreased piling-up energy of brain system during sleep in OSAS children.

  • PDF

Sleep Fragementation Decreases during the nCPAP Titration Night in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 압력 처방 검사 시 나타나는 수면분절의 감소)

  • Lee, Jin-Seong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.82-86
    • /
    • 2008
  • Objectives: Obstructive sleep apnea syndrome (OSAS) not only causes respiratory disturbances during sleep but also decreases the quality of nocturnal sleep through sleep fragmentation and sleep structure change. We aimed at comparing the changes in sleep fragmentation and structure between baseline (diagnostic) nocturnal polysomnography (NPSG) and nCPAP (nasal continuous positive airway pressure) titration trial. Methods: One hundred and three patients with a baseline night of respiratory disturbance index (RDI) of 5 or greater and reduced RDI score during nCPAP titration night were retrospectively selected for the study. Sleep fragementation and sleep structure between baseline NPSG and the NPSG during nCPAP titration were compared. Sleep fragmentation index (SFI) was defined as the total number of awakenings and shifts to stage 1 sleep divided by the total sleep time in hour. SFI and other polysomnographic parameters were statistically compared between the two nights. Results: SFI during baseline NPSG and nCPAP titration nights were $29.0{\pm}13.8$ and $15.2{\pm}8.8$, respectively, indicating a significant SFI decrease during nCPAP titration (t=9.7, p<0.01). SFI showed significant negative correlations with sleep efficiency (r=-0.60, p<0.01) and total sleep time (r=-0.45, p<0.01) and a positive correlation with RDI (r=0.28, p<0.01). Conclusion: Use of nCPAP, even during the titration, significantly decreases sleep fragmentation and improves sleep structure in OSAS patients. We suggest that SFI may be utilized as a measure of assessing OSAS severity and nCPAP efficacy.

  • PDF

Alternation of Sleep Structure and Circadian Rhythm in Alzheimer's Disease (알츠하이머 치매에서 수면구조 및 일주기리듬의 변화)

  • Sohn, Chang-Ho
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.9-13
    • /
    • 2002
  • Alzheimer's disease (AD) is one of the most common and devastating dementing disorders of old age. Most AD patients showed significant alternation of sleep structure as well as cognitive deficit. Typical findings of sleep architecture in AD patients include lower sleep efficiency, higher stage 1 percentage, and greater frequency of arousals. The slowing of EEG activity is also noted. Abnormalities in REM sleep are of particular interest in AD because the cholinergic system is related to both REM sleep and AD. Several parameters representing REM sleep structure such as REM latency, the amount of REM sleep, and REM density are change in patients with AD. Especially, measurements of EEG slowing during tonic REM sleep can be used as an EEG marker for early detection of possible AD. In addition, a structural defect in the suprachiasmatic nucleus is suggested to cause various chronobiological alternations in AD. Most of alternations related to sleep make sleep disturbances common and disruptive symptoms of AD. In this article, the author reviewed the alternation of sleep structure and circadian rhythm in AD patients.

  • PDF

Sleep in Panic Disorder and Nocturnal Panic Attack (공황장애의 수면과 야간 공황발작)

  • Ha, Ju-Won;Eun, Hong-Bae;Lim, Se-Won
    • Sleep Medicine and Psychophysiology
    • /
    • v.18 no.2
    • /
    • pp.57-62
    • /
    • 2011
  • Sleep disturbance is a one of common complaints among patients with panic disorder. However, clinicians and researchers did not give much attention to the sleep symptoms of panic disorder yet. Several previous studies suggested that the sleep disturbance in panic disorder is mediated by nocturnal panic attack. In terms of the pathophysiology of panic disorder, nocturnal panic attack seems to be closely associated with the sleep problems in panic disorder. In this article, the authors reviewed various previous studies about sleep of panic disorder and intended to give importance of evaluating sleep disturbances and nocturnal panic attack in panic disorder for both clinical and research purpose.

Numerical modeling of rapidly varied flow using the SST turbulence model and a hybrid free-surface capturing approach (자유수면 포착기법과 난류모형을 이용한 급변류 수치모델링)

  • Kim, Byung Ju;Paik, Joongcheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.149-149
    • /
    • 2020
  • 하천에서 물 흐름이 보와 댐과 같은 수공구조물을 지날 때 일반적으로 흐름상태에 다양하고 급진적인 변화가 발생한다. 특히 흐름이 구조물을 지나면서 사류(supercritical flow)로 변하고 다시 상류(subcritical flow)로 복원되면서 일어나는 도수(hydraulic jump) 현상은 수위의 급변화, 흐름 에너지 소산, 변동성이 강한 압력 분포 등이 특징이다. 이러한 흐름 특성들은 보나 여수로와 같은 수공구조물 자체의 성능뿐만 아니라 이들 수공구조물의 하류에서 발생하는 국부세굴로 인해 구조물의 안정성에 부정적인 영향을 줄 수 있다. 따라서 수공구조물을 설계할 때는 이들 구조물을 통과하는 흐름의 비정상 난류 흐름 특성을 정확하게 해석하여 반영하여야 한다. 이 연구에서는 k-omega SST 난류 모형과 자유수면의 급격한 변동을 해석하기 위한 하이브리드-VOF(hybrid volume of fluid)기법을 이용하여 도수현상을 수치적으로 재현하고자 한다. 기존 CFD(computational fluid Dynamics) 모델링에서는 자유수면 변동의 영향을 고려하기 위해 VOF 기법을 많이 사용하였다. 하지면 전통적인 VOF 기법은 다상흐름(multiphase flow)을 오직 부피분율(volume fraction)의 함수로만 고려하며 모의함으로써 강한 수면변동뿐만 아니라 공기연행(air entrainment)를 동반하는 난류 흐름을 모의하는데는 한계가 있다. 이 연구에서 이용하는 Eulerian 기법인 하이브리드 VOF 기법은 물과 공기의 각 상에 대하여 흐름 특성들을 개별적으로 계산하기 때문에 공기연행을 포함한 급변류 흐름에서 전통적인 VOF 기법보다 적용성이 우수하다. 이와 같은 난류모형과 자유수면 포착기법을 이용하여 3차원 비정상 난류 흐름 수치모형을 구축하여 수공구조물 주변에서 발생하는 강한 공기연행과 난류 특성를 보이는 급변류를 수치적으로 재현한다. 이 연구는 계산된 수치해석 결과를 기존 수리실험 결과와 비교하여 수치모형의 적용성을 평가하고 도수 현상에서 발생하는 독특한 흐름 특성을 제시한다.

  • PDF