• Title/Summary/Keyword: 수리저항

Search Result 175, Processing Time 0.028 seconds

Characteristics of the Fracture Distribution on the Granitic Rock by DC and VLF-EM Survey in the Northern Part of Yusong (유성북부 화강암지역에서 전기비저항탐사와 극저주파 전자탐사를 이용한 단열분포 특성)

  • 조성현;김천수;송무영
    • The Journal of Engineering Geology
    • /
    • v.9 no.1
    • /
    • pp.45-57
    • /
    • 1999
  • Groundwater flow in rock mass is controlled by the fractures developed in the area. So, the conductive fractures are very important for groundwater flow in crystalline rock. This study aims to find out the characteristics of the fracture distributed in granitic rock in the northern part of the Yusong area (latitude $36^{\circ}24'18"~36^{\circ}25'08",{\;}longitude{\;}127^{\circ}21'00"~127^{\circ}23'23"$). The electric and EM surveys were carried out in the site to delineate the fracture the fracture zones. Since geophysical survey provides non-unique solution, hydraulic data and dilling log data including BHTV scanning were used as complementary data to achieve the objective of this study. Electric survey(DC) arrays used are schlumberger and dipole-dipole arrays. VLF is used for EM survey. The main charcteristics of the fracture developed in the study aera are that fractures associated with basic dyke cut corss the main fracture zone in NNW and play an important role as hydraulic barrier. In trun, groundwater table in the upstream area is lower than that downstream area.

  • PDF

Variation of Manning's Coefficient due to Interval of Multi-Piers in Tunnel (터널내 다열기둥의 배치간격에 따른 Manning계수의 변화)

  • Yoon, Sung-Bum;Kwon, Kab-Keun;Lee, Sang-Min;Kim, Hyung-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.542-545
    • /
    • 2007
  • 터널의 노면 양쪽에 관로를 설치하여 유입된 지하수를 배출시키는 방법은 일반적인 터널 배수공법이지만 배수관로의 설치를 위한 추가적인 굴착은 공사기간과 공사비의 상승으로 이어지는 실정이다. 이에 터널 내에 별도의 배수관로 굴착 없이 노면 하부에 다열기둥을 일정 간격으로 매설하여 지하수의 흐름방향을 노면 하부로 유도시키는 경제적인 배수시스템이 현재 연구 중이다. 이 터널배수시스템은 추가적 굴착이 없어 기존의 배수시스템보다 경제적이지만 다열기둥의 연속적인 배치를 필요로 하므로 기존의 관로배수방식보다 더 많은 유체의 흐름저항을 받게 된다. 따라서 유체의 흐름에 효율적인 다열기둥 간의 배치간격에 대한 연구가 필요하다. 그래서 본 연구에서는 노면 하부에 다열기둥이 매설된 터널 내로 유입하는 지하수 배출을 목적으로 다열기둥 간의 배치간격에 따른 Manning계수의 변화를 수리실험을 통해 측정 분석하였다. 특히 Manning계수는 개수로에서 유체흐름 저항의 정도를 파악하는 데 이용되는 인자로 이를 활용하여 지하수 배수에 적절한 다열기둥 배치간격을 산정하였다. 본 연구를 통해 얻어진 수리실험 자료는 노면하부에 다열기둥을 매설하는 터널공사의 실제 설계를 위한 기초적인 참고자료로 사용될 것으로 기대된다.

  • PDF

A Study on the Erosion Resistance Performance of Biopolymer Mixed Soils According to Soil Types (토양 종류에 따른 바이오폴리머 혼합토의 침식저항 성능 연구)

  • Kim, Myounghwan;Lee, Du Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.221-221
    • /
    • 2021
  • 토양의 강도와 점성을 높여주는 바이오폴리머를 제방 호안에 도포하면 기존의 다른 호안 재료들과 마찬가지로 제방을 보호하는 것이 가능하다. 특히 바이오폴리머는 천연 토양과 혼합하여 사용하므로 다른 인공적인 호안재료들에 비해 생태적으로 유리하다. 하지만 바이오폴리머는 결합되어지는 토양의 점도, 공극률, 입도 등의 토양이 가지는 특성에 따라 성능이 변화하기 때문에 바이오폴리머를 이용한 혼한토를 제방 호안에 적용하기 위해서는 적절한 강도를 가지게 하는 토양을 선정해야 한다. 본 연구에서는 바이오폴리머를 마사토 및 황토 등과 결합하여 시험구를 설치하고 식생환경을 조성한 뒤 실규모 실험수로에서 수리 실험을 수행하여 바이오폴리머를 이용한 호안 공법의 침식 저항 성능을 평가하고 토양의 종류에 따라 성능을 비교하였다.

  • PDF

Numerical Experiment for Evaluation of Equivalent Resistance Coefficient according to Transverse Interval of Multi-Piers (다열기둥의 횡방향 간격변화에 따른 상당저항계수 산정 수치실험)

  • Kwon, Kab-Keun;Noh, Min;Choi, Jun-Woo;Yoon, Sung-Bum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.586-591
    • /
    • 2009
  • 권 등(2008)은 수면보다 높은 정방형 다열기둥의 수리실험을 수행하여 바닥마찰과 구조물에 의한 흐름저항을 포함하고 항력상호작용계수가 적용된 Manning계수 형태의 상당저항계수 이론식을 제안하였으나 저항체의 횡방향 간격에 대해서는 충분한 연구가 수행되지 못하였다. 따라서 본 연구에서는 오리피스의 에너지 손실계수를 적용하여 횡방향 간격에 따른 항력상호작용계수식을 제안하였다. 또한 정방형 다열기둥의 다양한 횡방향 간격에 따른 흐름양상을 FLOW-3D를 이용한 수치실험을 수행하여 상당저항계수 n을 측정하였으며 수치실험 결과를 본 연구에서 제안한 횡방향 항력상호작용계수식이 적용된 이론식과 비교하였다. 이론식과 수치실험 결과는 잘 일치하였으며 이 결과로부터 본 논문에서 제안한 횡방향 항력상호작용계수식이 유효함을 확인하였다.

  • PDF

현장 균열망 연결성 통합해석에 대한 선행연구

  • 김태희;황세호;채병곤;고경석;이철우;김용제
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.509-513
    • /
    • 2004
  • 현장 균열망의 연결성 및 이에 따른 수리지질학적 특성을 규명하기 위하여, 기존의 통상적인 조사 기법을 한 지역에 집적하여 그 결과에 대한 통합해석을 수행하였다. 본 연구에 적용된 조사 방법은 양수시험, 물리검층, 다중심도 수리화학 분석, 전기비저항 토모그래피, 시추 코어 검층 등의 기련 특성 조사와, 추적자 시험, 다중 심도 수직 유향유속 시험 등 구간별 특성 조사 등이다. 이러한 조사 결과 본 조사 지역 내 균열의 전반적인 분포 특성을 확인할 수 있었으며, 각 균열의 수리적 특성에 대한 기본적 특성을 확인할 수 있었다. 특히 추적자 시험과 유향유속 시험 결과를 통해 각 관정간의 균열을 통한 연결성에 대한 중요한 정보를 도출할 수 있었다. 이러한 성과는 추후 percolation, connectivity 등 모델 개념의 현장화를 위한 연구의 선행 연구로서 그 의미를 자리매김 할 수 있을 것이다.

  • PDF

Application of Electrical Resistivity Tomography Using Single Well in Seawater Intrusion Areas (해수침투지역에서 단일 시추공을 이용한 전기비저항 토모그래피 탐사의 적용성)

  • Song, Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.369-376
    • /
    • 2007
  • Electrical resistivity tomography was carried out at seawater intrusion monitoring wells located at watershed in coastal areas. It is difficult to identify the characteristics of resistivity near monitoring well in case of using high signalto-noise ratio array due to the high conductivity condition in coastal aquifer although electrical resistivity survey is well adopted to delineate hydrogeological characteristics with the distribution of electrical resistivity. To improve the quality of electrical resistivity survey for two sites with seawater intrusion monitoring wells, inversion with the results of holeto-surface electrical resistivity tomography using single well was executed. The results of inversion for aquifer near wells were verified with the results of drilling log with the informations of fracture, electrical conductivity logging and normal resistivity logging. The inversion for aquifer near one of two wells was also performed at low and high tide with the same electrodes, respectively. From the inversion result, it is possible to obtain the resistivity images with high resolution and to identify the characteristics of aquifer related to seawater intrusion with tidal fluctuation. From this study, it was demonstrated that the hole-to-surface electrical resistivity tomography method accompanied with drilling log, electrical conductivity logging and normal resistivity logging would be useful to delineate the hydrogeological structures near monitoring wells in coastal areas.

해수침투 우려지역에서 단일 시추공을 이용한 전기비저항탐사 적용

  • 김진호;송성호;용환호;정형재;우명하
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.528-531
    • /
    • 2003
  • 안산시 단원구 대부동, 보령시 청소면 장곡리와 서천군 비인면 선도리의 해안가 4곳에서 전기비저항 탐사를 이용하여 해수침투 조사용 관측정 주변의 대수층구조와 해수침투여부를 파악하고자 하였다. 공내수의 심도별 전기전도도를 확인 해본 결과, 4개의 조사공에서 180-48,000$\mu$S/cm의 각기 다른 값을 보였으며, 전기비저항 검층의 결과에서는 16인치 Short-Normal 검층 0.5-19.28$\Omega$m, 64인치 Long-Normal 검층 1.36-47.45$\Omega$m 그리고 Lateral 검층에서는 0.16-6.69$\Omega$m의 값의 분포를 보였다. 이를 통해 해수에 의해 지하수 및 주변 지질이 완전히 오염된 관측정과 우려되거나 아직 해수침투가 일어나지 않은 관측정을 구분할 수가 있었다. 또한 시추공-지표간 토모그래피를 통해 관측정 주변의 개략적인 수리지질 구조도 파악할 수 있었다.

  • PDF

Flow Resistance Characteristics of Hollowness-Block Channel Bed (중공블럭 하상의 흐름저항 특성)

  • Chae, Kuk-Sheok;Park, Sang-Deok;Shin, Seung-Sook;Cho, Jae-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.870-873
    • /
    • 2007
  • 하천의 수공 구조물은 홍수 시 작용하는 유수력에 대한 안정성을 확보해야 한다. 본 연구에서는 최근 개발된 친환경 식생호안블록인 중공블록을 하상에 설치할 경우 흐름에 미치는 영향을 연구하였다. 중공블록을 설치한 개수로에 대한 수리모형 실험을 실시하여 흐름저항과 경계층 특성에 대한 중공블록의 영향을 평가하였다. 흐름저항 특성 인자인 Manning의 조도계수와 Darcy-Weisbach의 마찰손실계수는 일정한 유량과 하상경사의 경우 수심에 큰 영향을 받고 이들은 서로 비례관계에 있음을 확인하였다. 그러나 마찰손실계수가 증가하더라도 어느 한계점 이상이 되면 조도계수는 일정한 값으로 수렴한다. 개수로의 경계층의 높이는 하천의 흐름특성과 구조특성을 반영하는 것으로 수심, 유속, 에너지경사, 경계면의 상대조도, Reynolds수, Froude수 등의 함수로 나타낼 수 있다. 중공블록이 설치된 개수로의 조도계수는 일반하천의 경우와 비교하여 큰 값을 나타내고 있어 중공블록이 흐름저항을 크게 증가시키는 것으로 판단된다.

  • PDF

Relationship Between the Groundwater Resistivity and NaCl Equivalent Salinity in Western and Southern Coastal Areas, Korea (국내 서.남해 해안지역 지하수의 전기비저항과 등가 NaCl 염분도와의 관계)

  • Hwang, Se-Ho;Park, Kwon-Gyu;Shin, Je-Hyun;Lee, Sang-Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.361-368
    • /
    • 2007
  • In this paper, we suggested the relationship between resistivity of coastal groundwater and NaCl equivalent salinity for the quantitative interpretation the results of surface/borehole resistivity and electromagnetic data. 38 groundwater samples having electrical conductivity higher than about 1,000 ${\mu}S/cm$ were analyzed to derive the empirical relationship between groundwater resistivity and NaCl equivalent salinity. We used Schlumberger chart GEN-8 to convert ion concentration from hydrochemical analysis to the equivalent NaCl salinity, and the portable meter to measure the in situ electrical conductivity of groundwater samples. From the hydrochemical analysis, relationship between the groundwater resistivity $(R_w)$ and equivalent NaCl salinity (Eq_NaCl) is expressed as Eq_NaCl=$5935.3551{\times}R_w^{-1.0993}$, and relationship between the groundwater electrical conductivity (EC) and total dissolved solids (TDS) is expressed as TDS=0.721*EC. We believe these relationships are very useful to assess the seawater intrusion in western and southern coastal area.

Flow Resistance of Vertical Rib Sidewall in Open Channel (개수로 측벽 세로돌출줄눈의 흐름저항)

  • Park, Sang Deog;Ji, Min Gyu;Nam, A Reum;Woo, Tae Young;Shin, Seung Sook
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.9
    • /
    • pp.947-956
    • /
    • 2013
  • Most of flood protection walls built on the impingement in mountain rivers have been made of concrete. It may cause flood disasters because the smooth wall surface could increase flow velocity. In this study the hydraulic experiments was carried out to evaluate the effect of one side wall with rectangular vertical ribs on flow resistance in open channel. The ratio of the pitch between vertical ribs to its depth, ${\lambda}_{nv}$, was designed so that it include the so-called d type and k type roughness. The range of Froude number, $F_r$, based on hydraulic radius is 0.81~1.12. Flow resistance in the open channel with a rib sidewall depends on the interval length of each ribs and the flow discharge. Maximum flow resistance occurred when ${\lambda}_{nv}$ is 9. In the d type roughness which ${\lambda}_{nv}$ is less than 3, the flow resistance decreases with increase of flow discharge. In the k type roughness which ${\lambda}_{nv}$ is greater than 3, the flow resistance increases with increase of flow discharge. The increments of flow resistance are especially great when ${\lambda}_{nv}$ are 9 and 12. The resistance due to vertical rib is mostly by the shape resistance and the vertical rib on one sidewall of open channel affects on the flow resistance so that the equivalent roughness heights of vertical rib may occur in scale of flow depth. Therefore the vertical ribs may be used to reduce the flow velocity and to move the location of maximum flow velocity from the rib sidewall to the centerward in a cross section of channels.