• Title/Summary/Keyword: 수리온

Search Result 177, Processing Time 0.024 seconds

Investigation of ground condition charges due to cryogenic conditions in an underground LNG storage plant (지하 LNG 저장 시험장에서 극저온 환경에 의한 지반상태 변화의 규명)

  • Yi Myeong-Jong;Kim Jung-Ho;Park Sam-Gyu;Son Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.67-72
    • /
    • 2005
  • To investigate the feasibility of a new concept of storing Liquefied Natural Gas (LNG) in a lined hard rock cavern, and to develop essential technologies for constructing underground LNG storage facilities, a small pilot plant storing liquid nitrogen (LN2) has been constructed at the Korea Institute of Geoscience and Mineral Resources (KIGAM). The LN2 stored in the cavern will subject the host rock around the cavern to very low temperatures, which is expected to cause the development of an ice ring and the change of ground condition around the storage cavern. To investigate and monitor changes in ground conditions at this pilot plant site, geophysical, hydrogeological, and rock mechanical investigations were carried out. In particular, geophysical methods including borehole radar and three-dimensional (3D) resistivity surveys were used to identify and monitor the development of an ice ring, and other possible changes in ground conditions resulting from the very low temperature of LN2 in the storage tank. We acquired 3D resistivity data before and after storing the LN2, and the results were compared. From the 3D images obtained during the three phases of the resistivity monitoring survey, we delineated zones of distinct resistivity changes that are closely related to the storage of LN2. In these results, we observed a decrease in resistivity at the eastern part of the storage cavern. Comparing the hydrogeological data and Joint patterns around the storage cavern, we interpret this change in resistivity to result from changes in the groundwater flow pattern. Freezing of the host rock by the very low temperature of LN2 causes a drastic change in the hydrogeological conditions and groundwater flow patterns in this pilot plant.

Time Series Analysis of the Responses of the Groundwater Levels at Multi-depth Wells According to the River Stage Fluctuations (시계열 분석을 이용한 하천수위에 따른 다심도 관정의 지하수위 변동해석)

  • Ha Kyoo-Chul;Ko Kyung-Seok;Koh Dong-Chan;Yum Byoung-Woo;Lee Kang-Kun
    • Economic and Environmental Geology
    • /
    • v.39 no.3 s.178
    • /
    • pp.269-284
    • /
    • 2006
  • Aquifer responses to the river stage fluctuations were analyzed between the groundwater level and the river stage in an alluvial aquifer. The auto-correlation and cross-correlation as a time series analysis were applied. Study site is a floodplain in the Mangyeong river. Groundwater levels in each depth representing the silt and sand(SS), gravel and sand(GS), and weathered zone(WZ) layer were monitored. The groundwater levels were more sensitive to the river stage fluctuations than rainfall. Since the river stages are influenced by the gate operations downstream and tide, show periodic patterns, and the correlation coefficients with rainfall is low. Cross-correlation function between groundwater level in each depth do not show any delay time, then response time is very short to each depth. Cross-correlation analysis were performed to estimate the response time of groundwater levels to river stage fluctuations. Groundwater levels respond to the river stage within 30 minutes to 1 hour in wells near the stream. Short time lag between groundwater level and river stage indicates the quick response. A different response time imply the hydraulic inhomogeneity of the site, and a probable high permeability zone between river and aquifer can be inferred. Mangyeong-river in study site is a gaining stream normally, and river stage rising by gate operation or floods makes river water flow into groundwater. The auto-correlation and cross-correlation functions as a time series analysis can be a good tool to interpret the aquifer responses to stream stage fluctuation

Hydrologic Characterization through Ground Water Monitoring in a Coastal Aquifer (해안 대수층에서 지하수 장기 모니터링을 통한 수리 특성 조사)

  • Shim, Byoung-Ohan;Lee, Chol-Woo
    • Economic and Environmental Geology
    • /
    • v.44 no.3
    • /
    • pp.239-246
    • /
    • 2011
  • Groundwater in small islands is used as main water resource but the overuse of groundwater may cause seawater intrusion and temperature decrease in geothermal wells. This study aimed to characterize the hydrogeology of Maeum-ri area in Seokmo Island of Ganghwagun using long-term monitoring at groundwater wells and geothermal wells. In the monitoring period seasonal water level change, consistent drop or increase of water levels are not detected. The groundwater temperature about 10m below ground surface shows year cycle variation having two to five months difference with ambient temperature cycle. The storativity was calculated by tidal method. The storativity estimated by adapting tidal efficiency factor showed some larger values than that by using tidal time lag. The result suggested that the tidal method assuming several assumptions on aquifer condition may produce broad ranges but the calculated ranges at this application are reasonable. The similar shape of groundwater level change and tidal effects was observed at several wells clustered east-south-east direction which may implicate the distribution of vertical fracture system strongly related with groundwater flow channels. The applied methodology and study results will bc valuable to evaluate optimal pumping rate for the preservation of groundwater resources, and to manage geothermal development.

Hydrogeochemistry and Statistical Analysis for Low and Intermediate Level Radioactive Waste Disposal Site in Gyeongju (경주 중·저준위 방폐장의 수리지화학 및 통계 분석)

  • Soon-Il Ok;Sieun Kim;Seongyeon Jung;Chung-Mo Lee
    • Journal of the Korean earth science society
    • /
    • v.44 no.6
    • /
    • pp.629-642
    • /
    • 2023
  • Currently, low and intermediate level radioactive waste is being disposed of at the Gyeongju disposal site for permanent isolation. Since 2006, the Korea Radioactive Waste Agency has been conducting site characteristics surveys continuously verifying changes in the site based on the site monitoring and investigation plan. The hydrogeochemical environment of the disposal site is considered for the evaluation of natural barriers. However, the seawater must be considered because of the regional characteristics of Gyeongju, which is near the East Sea. Therefore, this study, collected 30 samples for deriving the groundwater quality data from seven wells and compared with two seawater samples collected from October 2017 to June 2022. Additionally, the study explores the groundwater monitoring method using statistical tools such as clustering and background concentration analysis. The groundwater samples in the study area were classified into two to four clusters depending on their chemical constituents-especially, EC, HCO3, Na, and Cl-using statistical analysis, molar ratio, and K-means clustering.

A Case Study of SE and EVMS Techniques Application on Surion Helicopter R&D Program (수리온헬기 개발사업에서 시스템 엔지니어링 및 사업성과관리 기법 적용 사례연구)

  • Byun, Hyung Kyun;Lee, Sang Woo
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.8 no.1
    • /
    • pp.51-62
    • /
    • 2012
  • The System Engineering(SE) and the Earned Value Management System(EVMS), as parts of the scientific project management methodology, have been applied to Surion Helicopter R&D Program. The concept and application process of SE methodology, requirements management and applications output by DOORS program are described in this study. The concept and application process of EVMS, analysis results of schedule/cost variance for Surion RF equipment are also discussed in this study. Though the Surion R&D program is still on-going, it is found that the measures of effectiveness of SE and EVMS applications are verified.

Development of GIS-based Arc River Data Model for Building Three-dimensional River Information System (3차원 하천정보화시스템 구축을 위한 GIS 기반 Arc River 데이터 모델 개발)

  • Kim, Dong-Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.214-214
    • /
    • 2012
  • 본 논문은 최근 세계적으로 활발히 진행되고 있는 수리정보화시스템의 한 부분이 될 수 있는 하천정보화시스템의 구축의 근간이 되는 3차원 하천 자료 모형으로 개발된 아크리버 (Arc River)자료 모형을 소개한다. Arc River는 지리정보시스템(GIS)에 기반하여 수립되었고 최신 하천 유동 및 하상 계측기법으로 확보된 방대한 양의 관측 자료를 수집, 저장, 처리, 검색, 그리고 분석할 수 있게 하는 표준화된 자료 모형 (data model)이다. Arc River는 지난 10년간 유역 자료 모형의 표준으로 사용되어 온 Arc Hydro 모델의 한계를 극복하여 3차원에서 시공간적으로 변화하는 복수의 하천 관측 자료를 효율적으로 연계하고 GIS에서 활용할 수 있도록 설계되었다. 본 논문은 Arc River의 다양한 설계 원리에 대해 설명하고 실제 ADCP 자료를 활용하여 활성화된 Arc River의 예를 제시한다. Arc River는 향후 하천을 유지, 관리, 해석에 있어 필요한 3차원 하천정보화시스템의 구축의 근간을 이루고 국내에서도 그 활용을 범위를 넓힐 것으로 기대한다.

  • PDF

Mathematical Models of Photosynthetic Rate of Hydroponically Grown Cucumber Plants as Affected by Light Intensity, Air Temperature, Carbon Dioxide and Leaf Nitrogen Content (광도, 온도, $\textrm{CO}_2$ 농도 및 엽중 질소농도의 변화에 따른 양액재배 오이의 광합성속도에 관한 수리적 모형)

  • 임준택;백선영;정현희;현규환;권병선
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.171-178
    • /
    • 2000
  • Gross photosynthetic rats of leaves of hydroponically grown cucumber plants(Cucumis sativus L. cv. Guwoosalichungjang) were measured under various conditions of photosynthetic photon flux(PPF), ambient $CO_2$ concentration, air temperature and leaf nitrogen contents. Light compensation point of leaf photosynthesis appeared to be in the range of 10~20$\mu$mol.m$^{-2}$ .s$^{-1}$ and light saturation point be above 1000$\mu$mol.m$^{-2}$ .s$^{-1}$ . Gross photosynthetic rates increased persistently and asymptotically as air temperature rose from 12$^{\circ}C$ to 32$^{\circ}C$. However, there were only small differences in gross photosynthetic rates in the range of 24-32$^{\circ}C$, so that the range seemed to be optimal for photosynthesis of cucumber plants at the condition of $CO_2$ concentration of 400$\mu$mol.mol$^{-1}$ and PPF of around 400$\mu$mol.m$^{-2}$ .s$^{-1}$ . $CO_2$ compensation point of leaf photosynthesis appeared to be in the range of 20-40$\mu$mol.mol$^{-1}$ and $CO_2$ saturation point be above 1200$\mu$mol.mol$^{-1}$ . Gross photosynthetic rates increased sigmoidally as leaf nitrogen content increased. These environmental factors interacted synergistically to enhance gross photosynthetic rate, so that the rate increased multiplicatively s level of one factor increased progressively with higher levels of he other factors. Mathematical models wer developed to estimate the gross photosynthetic rate in accordance with the variations of these environmental factors. These modes can be used not only to explain he variation of growth or yield of cucumber plants under different environmental conditions but also as building blocks of plant growth model or expert system of cucumber plants.

  • PDF

A Study on Reliability Improvement of RALT for KUH through Fault Analysis (한국형기동헬기 레이더고도계의 결함분석을 통한 신뢰성 향상에 관한 연구)

  • Jun, Byung Kyu;Kim, Young Mok;Chang, Joong Jin;Kim, Chang Young;Hwang, Gil Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.5
    • /
    • pp.406-414
    • /
    • 2014
  • In this paper, it is introduced characteristics of FMCW-type Radar Altimeter for KUH, and its defects occurred during ground/flight test in initial product phase. In addition, it is also described 'data/control flow model' based fault analysis results of S/W and processes of verifying improvement design through flight test as well as aircraft system integration test called MEP SIL. As a result of design improvement and verification, it is validated that settling the defects and improving not only safety but also capability of the KUH.

Applicability of Geophyscal Well Logging in the Assessment of Seawater Intrusion (임해지역 해수침투 평가를 위한 물리검층의 적용성)

  • Lee Sang-Gyu;Hwang Sae-Ho;Hwang Hak-Su;Park In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.3
    • /
    • pp.101-111
    • /
    • 2000
  • In order to assess the seawater intrusion, induction, temperature and conductivity of fluid, and natural gamma logs were obtained in nine wells at the three study areas having different hydrogeologic characteristics. Besides surface geophysical exploration, supplementary geophysical well logs were carried out to understand the hydrogeological characteristics related to the seawater intrusion in the study areas. The geophysical well logs have been proved to increase the accuracy of interpretation of the surface geophyscial exploration's data for assessment of seawater intrusion, and to get the optimum depth for a long monitoring of groundwater. They, also, revealed that the identification of hydrogeological units for strata's porosity was able to be achieved and were illustrated the applicability of geophysical well logs monitoring. Finally, geophysical well logs are expected to play to get the more quantitative information of seawater infusion, if it is fully collaborated with a better method that is strata's resistivity determination with not relatively much effected by seawater within the drilled borehole and that is the porosity measurement with built on small diameter PVC casing.

  • PDF

Numerical Analysis on Consolidation of Soft Clay by Sand Drain with Heat Injection (수치해석을 통한 샌드드레인과 열주입에 의한 연약지반의 압밀 해석)

  • Koy, Channarith;Yune, Chan-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.11
    • /
    • pp.45-57
    • /
    • 2017
  • Temperature change affects consolidation behavior of soft clays. The increase of temperature in soft clays induces the increase of pore water pressure. The dissipation of the excess pore water pressure decreases volume and void ratio. Also, the consolidation rate is accelerated by high temperature which induces the decrease of viscosity of pore fluid. The effects of temperature on the consolidation behavior such as consolidation settlement, consolidation time, and pore water pressure were investigated in this study. A numerical analysis of hydro-mechanical (HM) and thermo-hydro-mechanical (THM) behavior was performed. The combination of heat injection and sand drain for consolidating the soft ground, with varying temperature (40 and $60^{\circ}C$) and sand drain diameter (40, 60, and 80 mm), was considered. The results show that the temperature inside soil specimen increases with the increase of the temperature of heating source and the diameter of sand drain. Moreover, the heat injection increases the excess pore water pressure and, accordingly, induces additional settlement in overconsolidated (OC) state and reduces the consolidation time in normally consolidated (NC) state.