• Title/Summary/Keyword: 수력 효율

Search Result 143, Processing Time 0.03 seconds

Study on the Device for Pump Efficiency Measurement (펌프의 효율측정 장비에 관한 연구)

  • Bae, Cherl-O
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.33
    • /
    • pp.53-62
    • /
    • 2012
  • Pumps are used widely in feed water, cooling & heating system and process line of industrial and construction fields. They consume nearly 20% of the each nation's total electrical energy. But The management of pump energy wasn't controlled well. Their loss of energy is huge if they have been operated at low efficiency. The first buying cost of pump is small compare to the power consumption of pump, so we can recommend the suitable replace time and best operating condition of parts and pump to measure the pump efficiency. Pump efficiency is usually measured according to the two methods which they are called thermodynamic method and traditional technique. And we measured the pump efficiency using two methods using potable pump efficiency measurement device and compared the results with the real performance curve offered from pump maker.

  • PDF

Study on the Hydraulic and Thermal Characteristics of Metallic Porous Medium (다공성 금속의 수력 및 열 교환 특성에 관한 연구)

  • Jin, M.H.;Kim, P.H.;Lee, Y.H.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.12 no.5
    • /
    • pp.54-58
    • /
    • 2008
  • 최근 열교환기의 향상을 위해 발포다공성매체의 적용이 증가하고 있다. 열교환기의 적용에 있어서 발포다공성매체의 이점을 살펴보기 위해 본 연구에서는 2가지 실험을 수행하였다. 첫 번째는 수력의 관점에서 투과계수 및 내부계수를 결정하는 것이고, 두 번째는 열교환의 관점에서 다공성매체의 유효전도율을 측정하는 것이다. 본 실험에서는 기공도는 거의 같으나 기공의 크기가 각각 20 ppi와 40 ppi인 구리 다공성매체를 사용하였다. 실험의 결과는 40 ppi 크기의 다공성매체가 수력과 열교환, 두가지 관점 모두에서 보다 높은 저항 효율을 나타낸다는 것을 보여준다.

  • PDF

Development of Micro-Hydro power generator using AS screw Turbine (AS 스크류 수차를 활용한 초소수력 발전기 개발)

  • Lee, Hyosang;Kang, Dongyun;Lee, Jaeil;Lee, Hyunseok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.122-122
    • /
    • 2022
  • 기후변화 대응 및 탄소 저감 노력의 일환으로 신재생에너지의 개발 및 활용이 전 세계적으로 활발하며, 우리나라에서도 2050년 탄소중립 달성을 위하여 친환경 에너지 시스템 구축에 많은 노력을 기울이고 있다. 전통적인 재생에너지인 수력은 발전의 효율성, 안정성과 발전 제어의 용이함 때문에 널리 사용되고 있으나, 경제성을 확보하기 위한 댐, 보의 설치 및 대규모 발전설비가 필요하여, 생태계, 환경 파괴 등의 문제점 등을 수반하여, 최근 들어 대규모 사업이 이루어지지 못하고 있다. 이러한 흐름에 따라 최근에는 유럽을 중심으로 친환경 소수력 발전으로 회전 나선형 아르키메데스 수차를 활용한 소수력 발전의 적용이 이루어지고 있으며, 특히 2000년대 이후 독일을 중심으로 활발히 개발되고 있다. 또한 휴대용 초소수력 발전은 새로운 산업분야로 민간용 초소수력 발전기의 개발 및 판매가 국내외에서 증가하고 있으며, 우리나라에서도 자연 하천 환경에 활용 가능한 초소수력 발전의 필요성이 꾸준히 제기되고 있다. 본 연구에서는 저유량 및 저낙차에 적용 가능한 '초소형 회전 나선형 아르키메데스 수차', 초소형 발전에 적합한 '발전기 및 발전시스템', 자연환경을 훼손하지 않는 친환경 '유도수로'로 구성되어, 원하는 하천이나 수로 등에 손쉽게 설치 가능한 초소형 소수력 발전시스템을 개발하였다. 회전 나선형 아르키메데스 수차는 3D프린터로 제작한 후, 강화 코팅제를 도포하여 내구성을 확보하였다. 상용 AC발전기, 소형 발전기용 '발전기 및 발전시스템'을 적용하고, 콘트롤 보드를 맞춤형으로 제작하여 경제성을 확보하였다. 이러한 발전 시스템은 개발 테스트 중에 있으며 향후 방류수로, 하수구 등 현장 적용을 준비 중에 있다.

  • PDF

Removal of Low Concentration Ammonia Nitrogen using a Packed Bed Bioreactor Immobilized with Nitrifier Consortium (질화세균을 고정화한 충전층 생물반응기에서 저농도 암모니아성 질소 제거)

  • Lee, Chang-Keun;Kim, Byong-Jin;Lee, Min-Su;Kim, Yong-Ha;Suh, Kuen-Hack
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.16-21
    • /
    • 2007
  • This study estimated the effect of hydraulic residence time(HRT), influent total ammonia nitrogen(TAN) concentration, temperature and pH in the packed-bed bioreactor using immobilized nitrifiers. Removal rate of ammonia nitrogen was increased with decreasing HRT and the optimum HRT was 0.2 hour when influent TAN was $2g/m^3$. At this point, removal rate was $226.1\;g/m^3{\cdot}day$ and removal efficiency was 88.8%. Removal rate of ammonia nitrogen was Increased with increasing TAN concentration. Removal rate and efficiency of ammonia nitrogen were kept constant at $20{\sim}35^{\circ}C$ and pH $8{\sim}9$ value.

  • PDF

Water Tests of Lox Pump for 75-ton Class Liquid Rocket Engine (75톤급 액체로켓엔진용 산화제펌프의 수류시험)

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.122-128
    • /
    • 2011
  • A series of water tests of a Lox pump for liquid rocket engines are performed at a room temperature. According to the hydraulic test results, the head coefficient is slightly decreased when the rotational speed of the pump is increased. However the efficiency is high at the high-speed test. Also, according to the cavitation test results, the cavitation performance of the pump is found to be decreased when the flow ratio is less than 92%. Furthermore, the vibration characteristic is analyzed using measured high frequency data.

Development of Modernization for Overseas Old Small Hydro Power Plants (해외 노후 소수력 발전소 현대화 개발 및 실증)

  • Kim, Woon-Hak;Kang, Seok-Won
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.235-236
    • /
    • 2017
  • 소수력발전소가 건설 후 점검 및 유지보수를 지속적으로 수행 설비성능을 유지하지만, 30년이 경과하면 노후화 및 피로현상으로 성능이 저하되고 경제적 내용연수가 도래한다. 대수력의 경우 전문인력과 점검 및 보수비용을 투자하여 일상, 주간, 월간, 년간, 정기보수를 수행하고 그 기록을 유지관리하고 있지만, 소수력발전소의 경우는 그러하지 못하여 발전소 효율뿐만 아니라 운용중의 안전도 위협받고 있는 상황이다. 본 논문에서는 국내 시설물 안전관리에 관한 특별법에 의거 필리핀에 위치한 노후 수력발전소의 현대화를 위하여 최초 기존 시설물에 대한 안전진단을 실시하여 토목 및 건축물의 보강을 위한 방법을 선정하고 이를 바탕으로 수력발전설비로부터 발생하는 진동과 같은 다양한 영향을 감소시키기 위한 토목기술을 반영하여 현지 환경에 적합한 수차선정과 노후 시설물의 유지보수를 국내 토목 보수 보강 기술로 설계하였다.

  • PDF

Predicting the success of CDM Registration for Hydropower Projects using Logistic Regression and CART (로그 회귀분석 및 CART를 활용한 수력사업의 CDM 승인여부 예측 모델에 관한 연구)

  • Park, Jong-Ho;Koo, Bonsang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.2
    • /
    • pp.65-76
    • /
    • 2015
  • The Clean Development Mechanism (CDM) is the multi-lateral 'cap and trade' system endorsed by the Kyoto Protocol. CDM allows developed (Annex I) countries to buy CER credits from New and Renewable (NE) projects of non-Annex countries, to meet their carbon reduction requirements. This in effect subsidizes and promotes NE projects in developing countries, ultimately reducing global greenhouse gases (GHG). To be registered as a CDM project, the project must prove 'additionality,' which depends on numerous factors including the adopted technology, baseline methodology, emission reductions, and the project's internal rate of return. This makes it difficult to determine ex ante a project's acceptance as a CDM approved project, and entails sunk costs and even project cancellation to its project stakeholders. Focusing on hydro power projects and employing UNFCCC public data, this research developed a prediction model using logistic regression and CART to determine the likelihood of approval as a CDM project. The AUC for the logistic regression and CART model was 0.7674 and 0.7231 respectively, which proves the model's prediction accuracy. More importantly, results indicate that the emission reduction amount, MW per hour, investment/Emission as crucial variables, whereas the baseline methodology and technology types were insignificant. This demonstrates that at least for hydro power projects, the specific technology is not as important as the amount of emission reductions and relatively small scale projects and investment to carbon reduction ratios.

Analysis of Water balance at Kwoesan Dam(2019) (2019년 괴산댐 유역 물수지 분석)

  • Hwang-Bo, Jong Gu;Kim, Ji Hun;Kim, Ki Young;Shin, In Jong;Myung, Moon Soo;Kim, Min Gyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.263-263
    • /
    • 2020
  • 댐 유역 수문자료는 댐의 효율적인 운영, 중장기 댐 운영 계획, 수자원 관리, 댐 저수량 예보 등에 사용된다. 댐의 주요 수문자료로는 일반적으로 유입량인 강수량과 유량으로 구성되어있으며 유출량인 방류량, 증발량, 토양수분량으로 구분한다. 현재 강수량, 유량, 방류량은 지속적으로 계측하고 있으나 증발산량과 토양의 저류량 등은 실제적으로 측정의 어려움을 가지고 있다. 본 연구에서는 실측자료를 물수지 방정식에 대입해 발생한 잔차를 통해 산출한 증발산량과 비교적 정확성이 높다고 알려져 있는 GLDAS NOAH 지형 모형자료에서 산정된 증발산량간의 비교를 수행하였다. 또한 이렇게 각각 산정한 증발산량으로 월별로 물수지 분석을 정량화하여 분석하였다. 유량자료는 후영교 수위관측소의 자료, 강수량은 괴산군(청천면사무소) 강수량관측소 외 15개소 자료, 댐 방류량자료 등의 실측자료를 사용하였으며, 증발량은 GLDAS NOAH 지표면 model을 이용하여 산정하였다. 저수지 토양수분량은 자료가 없어 고려하지 않았다. 2019년 괴산댐 유역의 총 유입량은 218.54 백만㎥이며, 증발량을 고려한 총 유출량은 200.50 백만㎥으로 나타나 댐의 저류량은 18.05 백만㎥으로 나타났다. 그러나 실제 저수지의 수위-저수용량 곡선식을 이용하여 계산된 총 저류량은 0.06 백만㎥으로 상당한 차이를 보이고 있다. 이 원인으로 1. 증발량 추정자료 사용, 2. 토양저류량 미 고려, 3. 자료가 없는 취수량 미 고려 4. 유량, 방류량, 강수량 자료 오차 등이 있는 것으로 판단된다. 한편, GLDAS NOAH 지표면 model을 이용한 연 저수지증발량과 물 수지 방적식을 이용한 연 저수지증발량은 각각 0.79 백만㎥, 18.84 백만㎥으로 나타나, 역시 차이를 보인다. 이는 물 수지 방정식을 이용한 연 저수지증발량은 토양수분증발량 미 고려에 따른 것과 GLDAS NOAH 지표면 model자료는 직접적인 실측 자료가 아닌 추정 자료로 다소 오차가 있을 것으로 생각된다. 댐 유역 물의 이동을 추적하고 이를 정량적으로 나타내는 것은 결과적으로 효율적인 댐 운영을 가능하게 한다. 그러나 최근 실시되는 유량측정과는 달리 물 수지 분석의 주요 인자인 증발량과 토양수분량 등은 측정이 전무하여 여러 가지 방법으로 추정하는 현실이다. 추후 이러한 수문자료를 실측하여 제공한다면 댐 관리 및 중장기 댐 운영 계획 수립 등 효율적인 댐 운영에 대단히 유용할 것으로 기대된다.

  • PDF

Evaluation of Power Generation Efficiency according to Geometric Characteristics of Reservoir in Micro Vortex Hydro-electric Power Generation System (마이크로 보텍스 수력발전시스템에 있어 저수조의 기하학적 특성에 따른 발전 효율 평가)

  • Jeong, Woo Chang;Kang, Hyun Sil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.432-432
    • /
    • 2021
  • 우리나라는 대부분의 에너지 공급을 해외에 의존하고 있는 실정이다. 산업통상자원부와 에너지경제연구원에서 발간하는 2018년 에너지통계연보(에너지경제연구원과 산업통상자원부, 2018)에 실린 2010년부터 2017년까지의 에너지수급 균형을 보면 원유, 천연가스, 석탄, 우라늄 등 평균 95.4%의 에너지를 수입하고 있는 실정이다. 수력 및 신재생에너지의 경우 기후변화에 대응하는 수단 그리고 정부의 저탄소에너지 전환 정책으로 인정받아 상대적으로 낮은 에너지 경제성에도 불구하고 꾸준히 보급되고 있다. 우리나라뿐만 아니라 독일, 프랑스, 영국, 중국 그리고 인도와 같은 세계 주요 국가들이 친환경 에너지 정책을 주도함에 따라 향후 신재생에너지의 공급 규모는 크게 확대될 것으로 전망된다. 중력 물 보텍스 마이크로 수력 발전 시스템은 시스템의 상하류부의 수두(hydraulic head) 차에 의해 저류조(basin)에서 발생되는 물의 보텍스 즉 소용돌이(whirlpool)를 이용하여 임펠러(impeller)를 회전시켜 전기에너지를 생산하는 친환경적 재생에너지의 일종이다. 또한, 시스템으로 유입되는 물은 전기에너지 생산을 위한 임펠러를 통과한 후 다시 하천으로 방류되므로 하천 수의 손실 그리고 하천의 물길도 거의 교란 시키지 않는다. 4가구 정도의 연간 가정용 전기 요구량인 12와 15kW 사이의 전기에너지를 생산하기 위해서는 발전시스템의 상류와 하류의 수두차가 단지 1.5에서 1.7m 이하이면 충분한 것으로 알려져 있다. 본 연구에서는 중력 물 보텍스 친환경 마이크로 발전 시스템을 구성하는 저류조(basin)에 대해 최대 발전효율을 발생시키기에 최적인 기하학적 형태를 도출하는 것이며, 이를 위해 저류조의 cone angle에 따른 다양한 저류조 직경 및 물 보텍스 생성을 위한 저류조 형태의 변화, 유입수로와 저류조와의 각도인 notch angle의 변화, 유입부 폭과 유출부 직경, 유입수로의 길이 그리고 유입수로에서의 초기수심과 같은 기하학적 매개변수를 변화시켜 모의를 수행하였다.

  • PDF

양수발전소의 경제성

  • 고달원
    • 전기의세계
    • /
    • v.15 no.1
    • /
    • pp.28-31
    • /
    • 1966
  • 양수발전소는 년평균 용량율이 극히 낮은 단시간운전을 대상으로 개발케 되므로 시설규모의 대용량화가 경제적이며 또한 일반적인 경향이다. 이러한 대용량화는 기계기구비의 증가 및 송수전손실을 수반하므로 이를 경감시키기 위하여는 가급적 수요중심지 혹은 고효율 화력기 접근할것이며 보다 고낙차임이 유리하게 됨은 종래의 수력지점 선정시와 같다. 이상에서 양수발전소의 개발계획은 예상되는 년용량율롸 밀접한 관계가 있다는것을 중심으로 서술하였다.

  • PDF